{"product_id":"automated-nucleic-acid-extraction-multiex-032","title":"32-throughput Automated Nucleic Acid Extraction System - MultiEx 032","description":"\u003c!-- ============================================================\n     Surge Scientific — Nucleic Acid Extractor\n     Model: MultiEX 032 — 32-throughput, individual heating modules\n     ============================================================ --\u003e\n\n\u003cstyle\u003e\n  :root {\n    --teal-deepest:#0d2b2b; --teal-dark:#0d4a4a; --teal-mid:#0a7373;\n    --amber:#bf6000; --teal-light:#e0f2f1; --teal-border:#b2dfdb;\n    --teal-pale:#80cbc4; --text-body:#2c4a4a; --text-secondary:#3a5a5a;\n    --hover-amber:#fff8e1; --white:#ffffff;\n  }\n  .prod-desc {\n    font-family:'Georgia','Times New Roman',serif; font-size:1em;\n    color:var(--teal-deepest); width:100%; max-width:100%;\n    box-sizing:border-box; line-height:1.7;\n  }\n  .prod-hero {\n    background:linear-gradient(135deg,#0d2b2b 0%,#0d4a4a 50%,#0a7373 100%);\n    color:var(--white); padding:clamp(1.5em,4vw,3em) clamp(1.25em,3vw,2.5em);\n    border-radius:4px; margin-bottom:clamp(1.5em,3vw,2.5em);\n    position:relative; overflow:hidden; box-sizing:border-box;\n  }\n  .prod-hero::before {\n    content:''; position:absolute; top:-60px; right:-60px;\n    width:220px; height:220px; border-radius:50%;\n    background:rgba(191,96,0,0.12);\n  }\n  .prod-hero::after {\n    content:''; position:absolute; bottom:-40px; left:35%;\n    width:160px; height:160px; border-radius:50%;\n    background:rgba(224,242,241,0.07);\n  }\n  .prod-hero-eyebrow {\n    font-family:'Arial',sans-serif; font-size:0.6875em; font-weight:700;\n    letter-spacing:0.18em; text-transform:uppercase;\n    color:var(--amber); margin:0 0 0.75em;\n  }\n  .prod-hero h1 {\n    font-family:'Arial',sans-serif; font-size:clamp(1.375em,2.5vw,1.875em);\n    font-weight:800; margin:0 0 0.5em; color:var(--white); line-height:1.2;\n  }\n  .prod-hero-sub {\n    font-family:'Arial',sans-serif; font-size:0.875em;\n    color:rgba(255,255,255,0.65); margin:0 0 1.5em; letter-spacing:0.04em;\n  }\n  .prod-hero-lead {\n    font-size:1.0625em; color:rgba(255,255,255,0.88);\n    max-width:100%; margin:0; line-height:1.75; font-style:italic;\n  }\n  .prod-section { margin-bottom:clamp(1.5em,3vw,2.5em); }\n  .prod-section-title {\n    font-family:'Arial',sans-serif; font-size:0.8125em; font-weight:700;\n    letter-spacing:0.18em; text-transform:uppercase;\n    color:var(--amber); border-bottom:2px solid var(--amber);\n    padding-bottom:0.5em; margin:0 0 1.25em; display:inline-block;\n  }\n  .prod-section p { font-size:1em; color:var(--text-body); margin:0 0 0.875em; }\n  .prod-pillars {\n    display:grid; grid-template-columns:repeat(2,minmax(0,1fr));\n    gap:clamp(0.75em,2vw,1em); margin-bottom:clamp(1.5em,3vw,2.5em);\n  }\n  .prod-pillar {\n    border:1px solid var(--teal-border); border-left:4px solid var(--amber);\n    padding:clamp(0.875em,2vw,1.25em) clamp(0.75em,1.5vw,1.125em);\n    background:var(--teal-light); border-radius:0 4px 4px 0;\n    box-sizing:border-box;\n  }\n  .prod-pillar-icon { font-size:1.5em; margin-bottom:0.5em; display:block; }\n  .prod-pillar-title {\n    font-family:'Arial',sans-serif; font-size:0.8125em; font-weight:700;\n    text-transform:uppercase; letter-spacing:0.06em;\n    color:var(--teal-deepest); margin:0 0 0.375em;\n  }\n  .prod-pillar p { font-size:0.875em; color:var(--text-secondary); margin:0; line-height:1.6; }\n  .prod-callout {\n    background:linear-gradient(135deg,var(--teal-light),#f9fefe);\n    border:1px solid var(--teal-border); border-left:5px solid var(--amber);\n    padding:clamp(0.875em,2vw,1.25em) clamp(0.875em,2vw,1.375em);\n    border-radius:0 4px 4px 0; margin-bottom:clamp(1.5em,3vw,2.5em);\n    box-sizing:border-box;\n  }\n  .prod-callout p { font-size:1.0625em; color:var(--teal-deepest); margin:0; font-style:italic; line-height:1.7; }\n  .prod-callout strong { color:var(--amber); font-style:normal; }\n  .prod-features {\n    list-style:none; padding:0; margin:0 0 1em;\n    display:grid; grid-template-columns:repeat(2,minmax(0,1fr));\n    gap:0.5em 1.5em;\n  }\n  .prod-features li {\n    font-size:0.875em; color:var(--text-body);\n    padding-left:1.375em; position:relative; line-height:1.5;\n  }\n  .prod-features li::before {\n    content:'✓'; position:absolute; left:0;\n    color:var(--amber); font-weight:700; font-size:1em;\n  }\n  .prod-usecases {\n    display:grid; grid-template-columns:repeat(3,minmax(0,1fr));\n    gap:clamp(0.625em,1.5vw,0.875em); margin-bottom:0.5em;\n  }\n  .prod-usecase {\n    background:var(--teal-dark); color:var(--white);\n    padding:clamp(0.875em,2vw,1.125em) clamp(0.75em,1.5vw,1em);\n    border-radius:4px; text-align:center; box-sizing:border-box;\n  }\n  .prod-usecase-icon { font-size:1.625em; display:block; margin-bottom:0.5em; }\n  .prod-usecase-title {\n    font-family:'Arial',sans-serif; font-size:0.75em; font-weight:700;\n    letter-spacing:0.06em; text-transform:uppercase;\n    color:var(--amber); margin-bottom:0.375em;\n  }\n  .prod-usecase p { font-size:0.8125em; color:rgba(255,255,255,0.75); margin:0; line-height:1.5; }\n  .prod-badges { display:flex; flex-wrap:wrap; gap:0.625em; margin-bottom:0.5em; }\n  .prod-badge {\n    font-family:'Arial',sans-serif; font-size:0.6875em; font-weight:700;\n    letter-spacing:0.06em; text-transform:uppercase;\n    background:var(--teal-dark); color:var(--white);\n    padding:0.4em 0.75em; border-radius:2px;\n  }\n  .prod-badge.amber { background:var(--amber); color:var(--white); }\n  .prod-badge.outline {\n    background:transparent; color:var(--teal-dark);\n    border:1.5px solid var(--teal-dark);\n  }\n  .prod-specs-wrap {\n    width:100%; overflow-x:auto;\n    -webkit-overflow-scrolling:touch; margin-bottom:0.5em;\n  }\n  .prod-specs-table {\n    width:100%; min-width:420px; border-collapse:collapse;\n    font-size:0.875em; font-family:'Arial',sans-serif;\n  }\n  .prod-specs-table thead tr { background:var(--teal-dark); color:var(--white); }\n  .prod-specs-table thead th {\n    padding:clamp(0.5em,1.2vw,0.625em) clamp(0.625em,1.5vw,0.875em);\n    text-align:left; font-size:0.6875em;\n    letter-spacing:0.12em; text-transform:uppercase; white-space:nowrap;\n  }\n  .prod-specs-table tbody tr:nth-child(even) { background:var(--teal-light); }\n  .prod-specs-table tbody tr:hover { background:var(--hover-amber); }\n  .prod-specs-table td {\n    padding:clamp(0.5em,1vw,0.5625em) clamp(0.625em,1.5vw,0.875em);\n    border-bottom:1px solid var(--teal-border);\n    color:var(--text-body); vertical-align:top;\n  }\n  .prod-specs-table td:first-child {\n    font-weight:600; color:var(--teal-deepest); width:36%;\n  }\n  .prod-warranty {\n    background:linear-gradient(135deg,#0a7373,#0d4a4a); color:var(--white);\n    padding:clamp(0.875em,2vw,1em) clamp(1em,2.5vw,1.5em);\n    border-radius:4px; display:flex; align-items:flex-start;\n    gap:0.875em; margin-top:clamp(1.5em,3vw,2.5em);\n    box-sizing:border-box;\n  }\n  .prod-warranty-icon { font-size:1.75em; flex-shrink:0; margin-top:0.125em; }\n  .prod-warranty p { margin:0; font-size:0.875em; line-height:1.5; }\n  .prod-warranty strong { color:var(--amber); }\n  @media (max-width:600px) { .prod-usecases { grid-template-columns:1fr; } }\n  @media (max-width:480px) {\n    .prod-pillars, .prod-features { grid-template-columns:1fr; }\n    .prod-hero h1 { font-size:1.25em; }\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"prod-desc\"\u003e\n\n  \u003c!-- ── 1. HERO BANNER ── --\u003e\n  \u003cdiv class=\"prod-hero\"\u003e\n    \u003cp class=\"prod-hero-eyebrow\"\u003eSurge Scientific · Model MultiEX 032 · 32-Throughput Nucleic Acid Extractor\u003c\/p\u003e\n    \u003ch1\u003eNucleic Acid Extractor\u003cbr\u003e32-Throughput · Individual Heating Modules · Auto-Check\u003c\/h1\u003e\n    \u003cp class=\"prod-hero-sub\"\u003e1–32 Samples \/ Run · Magnetic Bead Separation · Multiple Heating Zones with Independent Control · Touchscreen Interface · Auto-Verification\u003c\/p\u003e\n    \u003cp class=\"prod-hero-lead\"\u003e\n      The MultiEX 032 doubles the MultiEX 016's throughput to \u003cstrong\u003e32 samples per run\u003c\/strong\u003e — and adds the feature that mid-volume diagnostic labs actually need: \u003cstrong\u003emultiple heating modules with independent temperature control\u003c\/strong\u003e. That means lysis at one temperature and elution at another within the same run, no manual repositioning, no compromise on temperature accuracy. \u003cstrong\u003eAuto-check function\u003c\/strong\u003e verifies correct positioning of the 96-well plate and magnetic rods before every run — eliminating the \"I forgot to seat the plate\" failure mode that costs labs days of repeat extractions.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 2. WHY INDIVIDUAL HEATING ZONES MATTER ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eWhy Individual Heating Zones Beat a Single Heater\u003c\/p\u003e\n    \u003cp\u003e\n      Most nucleic acid extraction protocols need \u003cstrong\u003etwo or more distinct temperatures\u003c\/strong\u003e in a single run. \u003cstrong\u003eLysis is typically run at 56–95°C\u003c\/strong\u003e (proteinase K activation, then heat-kill); \u003cstrong\u003eelution is run at 65–80°C\u003c\/strong\u003e (release nucleic acid from beads); some viral and bacterial protocols add a third \u003cstrong\u003edenaturation step at 95–125°C\u003c\/strong\u003e. A single-zone heater forces the whole plate through every temperature change — heating delays, cooling delays, and a thermal gradient across the plate that no real protocol tolerates well.\n    \u003c\/p\u003e\n    \u003cp\u003e\n      The MultiEX 032's \u003cstrong\u003eindividual heating modules\u003c\/strong\u003e let each zone hit its target temperature independently. \u003cstrong\u003eThe lysis zone hits 95°C while the elution zone holds 65°C, simultaneously\u003c\/strong\u003e. No waiting for the whole plate to ramp. No thermal gradient eating into your purification consistency. The result is faster overall run time, tighter inter-well CVs, and yields that match what you'd get from manual column purification — without the manual hours.\n    \u003c\/p\u003e\n    \n    \u003cp\u003e\n      For decades, nucleic acid purification meant \u003cstrong\u003esilica spin columns and centrifuges\u003c\/strong\u003e — pipette, centrifuge, transfer, repeat. It works, but it's slow, manual, and expensive in tech-time per sample. Worse, every transfer step is a chance for contamination, sample loss, or operator error. For a lab processing more than a few samples a day, the column workflow is the bottleneck.\n    \u003c\/p\u003e\n    \u003cp\u003e\n      \u003cstrong\u003eMagnetic-bead extraction flipped the model.\u003c\/strong\u003e Magnetic beads coated with silica or specific affinity ligands bind nucleic acids in solution. A magnet pulls the beads (with bound nucleic acid) to the side of the well; the rest of the sample is washed away. Elution releases the purified nucleic acid in a small volume. \u003cstrong\u003eNo centrifuges. No transfer steps. No spin columns.\u003c\/strong\u003e Done in parallel, fully automated, with \u003cstrong\u003erecovery rates of 95%+ and inter-well CVs typically below 3%\u003c\/strong\u003e — directly comparable to gold-standard column purification, but at a fraction of the hands-on time.\n    \u003c\/p\u003e\n    \u003cp\u003e\n      The MultiEX series automates the entire process: \u003cstrong\u003eload the prepped 96-well plate, set the protocol on the touchscreen, walk away\u003c\/strong\u003e. The machine handles bead capture, washes, elution, and final dispense into a fresh plate ready for downstream analysis (PCR, qPCR, NGS, sequencing). UV disinfection between runs eliminates cross-contamination. Multi-temperature heating modules handle lysis and elution at the precise temperatures that maximize yield without nucleic acid degradation.\n    \u003c\/p\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- ── 3. FOUR VALUE PILLARS ── --\u003e\n  \u003cdiv class=\"prod-pillars\"\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e🧪\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003e32-Sample Throughput\u003c\/p\u003e\n      \u003cp\u003eProcess \u003cstrong\u003eup to 32 samples per run\u003c\/strong\u003e in a single 96-well plate. Magnetic-bead capture, washes, elution, and dispense — fully automated, hands-off after plate loading.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e🌡️\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003eIndependent Heating Modules\u003c\/p\u003e\n      \u003cp\u003e\u003cstrong\u003eMultiple heating zones with individual control\u003c\/strong\u003e — lysis at one temperature and elution at another, simultaneously. Eliminates the thermal gradient and ramp-time penalty of single-zone heaters.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e✅\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003eAuto-Check Function\u003c\/p\u003e\n      \u003cp\u003e\u003cstrong\u003eAuto-verification before every run\u003c\/strong\u003e — confirms correct positioning of the 96-well plate, magnetic rods, and rod sleeves. Catches setup errors \u003cstrong\u003ebefore they cost you a batch\u003c\/strong\u003e.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e🔬\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003eUniversal Sample Compatibility\u003c\/p\u003e\n      \u003cp\u003eMagnetic-bead extraction from \u003cstrong\u003ewhole blood, viruses, tissue, plants, animals, fungi, bacteria, cultured cells, swabs, feces, blood cards\u003c\/strong\u003e — one extractor handles every sample type your lab encounters.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 4. CALLOUT BOX ── --\u003e\n  \u003cdiv class=\"prod-callout\"\u003e\n    \u003cp\u003e\n      \u003cstrong\u003e\"32 samples. Two heating zones running simultaneously. Auto-checked before every run. The mid-throughput extractor that actually thinks about the protocol.\"\u003c\/strong\u003e —\n      For diagnostic and research labs running 20–60 samples per shift, the MultiEX 032 hits the sweet spot between throughput, temperature flexibility, and bench footprint.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 5. KEY FEATURES ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eKey Features\u003c\/p\u003e\n    \u003cul class=\"prod-features\"\u003e\n      \u003cli\u003eMagnetic bead-based separation technology\u003c\/li\u003e\n      \u003cli\u003e1–32 samples per run\u003c\/li\u003e\n      \u003cli\u003e96-well plate compatible\u003c\/li\u003e\n      \u003cli\u003eMultiple heating modules with individual control\u003c\/li\u003e\n      \u003cli\u003eIndependent lysis and elution temperatures\u003c\/li\u003e\n      \u003cli\u003eAuto-check function before each run\u003c\/li\u003e\n      \u003cli\u003eVerifies plate positioning\u003c\/li\u003e\n      \u003cli\u003eVerifies magnetic rod positioning\u003c\/li\u003e\n      \u003cli\u003eVerifies rod sleeve positioning\u003c\/li\u003e\n      \u003cli\u003eTouchscreen interface\u003c\/li\u003e\n      \u003cli\u003eUser-friendly protocol programming\u003c\/li\u003e\n      \u003cli\u003eFully automated extraction workflow\u003c\/li\u003e\n      \u003cli\u003eClosed system — minimizes contamination risk\u003c\/li\u003e\n      \u003cli\u003eUniversal sample compatibility\u003c\/li\u003e\n      \u003cli\u003eWhole blood, virus, tissue, plant samples\u003c\/li\u003e\n      \u003cli\u003eAnimal, fungal, bacterial samples\u003c\/li\u003e\n      \u003cli\u003eCultured cell, swab, fecal, blood card samples\u003c\/li\u003e\n      \u003cli\u003eCompatible with all magnetic-bead kits\u003c\/li\u003e\n      \u003cli\u003eOpen-system reagent design\u003c\/li\u003e\n      \u003cli\u003eHigh DNA \/ RNA yield\u003c\/li\u003e\n      \u003cli\u003eStable inter-run reproducibility\u003c\/li\u003e\n      \u003cli\u003eReduced hands-on time\u003c\/li\u003e\n      \u003cli\u003eSuitable for research labs\u003c\/li\u003e\n      \u003cli\u003eSuitable for clinical molecular diagnostics\u003c\/li\u003e\n      \u003cli\u003eSuitable for pharmaceutical \/ biotech labs\u003c\/li\u003e\n      \u003cli\u003eCompact bench footprint\u003c\/li\u003e\n      \u003cli\u003eEasy setup — no special infrastructure required\u003c\/li\u003e\n      \u003cli\u003eMinimal maintenance\u003c\/li\u003e\n      \u003cli\u003e2-year all-inclusive warranty\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 6. IDEAL APPLICATIONS ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eIdeal Applications\u003c\/p\u003e\n    \u003cdiv class=\"prod-usecases\"\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e🏥\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003eMolecular Diagnostics\u003c\/p\u003e\n        \u003cp\u003eClinical molecular diagnostics labs running infectious disease, oncology, or genetic-testing panels — 32-sample batches fit a typical diagnostic shift workload without manual extraction backlogs.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e🔬\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003eResearch \u0026amp; Academic Labs\u003c\/p\u003e\n        \u003cp\u003eGovernment and academic research — molecular biology, microbiology, virology, plant science, environmental DNA — where reproducible mid-volume extraction underpins every downstream PCR\/qPCR\/NGS workflow.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e💊\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003ePharma \u0026amp; Biotech\u003c\/p\u003e\n        \u003cp\u003ePharmaceutical and biotech R\u0026amp;D — drug discovery, biomarker validation, genotyping pipelines — where 32-sample throughput meets early-stage screening volumes without committing to a 96-throughput investment.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 7. WHAT'S IN THE BOX ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eWhat's in the Box\u003c\/p\u003e\n    \u003cp\u003eThe MultiEX 032 ships ready for routine use — all hardware, touchscreen interface, and documentation included. Reagent kits and consumables sold separately to match your sample type.\u003c\/p\u003e\n    \u003cdiv class=\"prod-badges\"\u003e\n      \u003cspan class=\"prod-badge amber\"\u003eMultiEX 032 Extractor\u003c\/span\u003e\n      \u003cspan class=\"prod-badge amber\"\u003eTouchscreen Interface\u003c\/span\u003e\n      \u003cspan class=\"prod-badge amber\"\u003eMultiple Heating Modules\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003ePower Cord\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003eUser Manual\u003c\/span\u003e\n      \u003cspan class=\"prod-badge outline\"\u003eMagnetic Bead Reagent Kit (Optional)\u003c\/span\u003e\n      \u003cspan class=\"prod-badge outline\"\u003e96-Deep Well Plates (Optional)\u003c\/span\u003e\n      \u003cspan class=\"prod-badge outline\"\u003eValidation Service (Optional)\u003c\/span\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 8. TECHNICAL SPECIFICATIONS ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eTechnical Specifications\u003c\/p\u003e\n    \u003cdiv class=\"prod-specs-wrap\"\u003e\n      \u003ctable class=\"prod-specs-table\"\u003e\n        \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003eModel \/ SKU\u003c\/td\u003e\n\u003ctd\u003eMultiEX 032\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eThroughput\u003c\/td\u003e\n\u003ctd\u003e1–32 samples per run\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePlate Type\u003c\/td\u003e\n\u003ctd\u003e96-well plate\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSeparation Method\u003c\/td\u003e\n\u003ctd\u003eMagnetic bead-based\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eReagent System\u003c\/td\u003e\n\u003ctd\u003eOpen — compatible with all magnetic-bead kits\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eHeating Modules\u003c\/td\u003e\n\u003ctd\u003eMultiple — independently controlled\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eAuto-Check\u003c\/td\u003e\n\u003ctd\u003ePlate, rod, rod sleeve positioning verified before each run\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eColor touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eOperation Mode\u003c\/td\u003e\n\u003ctd\u003eFully automated\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSample Compatibility\u003c\/td\u003e\n\u003ctd\u003eWhole blood · virus · tissue · plant · animal · fungi · bacteria · cells · swab · feces · blood card\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eWorkflow Stages\u003c\/td\u003e\n\u003ctd\u003eBinding · mixing · washing · elution\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eClosed System\u003c\/td\u003e\n\u003ctd\u003eYes — minimizes cross-contamination\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eIntended Use\u003c\/td\u003e\n\u003ctd\u003eResearch · clinical · diagnostic · pharmaceutical \/ biotech labs\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-year all-inclusive\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n    \u003cp style=\"font-size:0.875em; color:var(--text-secondary); font-style:italic; margin-top:0.5em;\"\u003e\n      Detailed numerical specifications (heating range, temperature accuracy, processing volume range, dimensions) available on request — contact our product specialists for the full technical datasheet.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 9. WARRANTY \u0026 SUPPORT ── --\u003e\n  \u003cdiv class=\"prod-warranty\"\u003e\n    \u003cspan class=\"prod-warranty-icon\"\u003e🛡️\u003c\/span\u003e\n    \u003cp\u003e\n      \u003cstrong\u003eSurge Scientific Warranty \u0026amp; Support\u003c\/strong\u003e\u003cbr\u003e\n      This instrument is sold through Surge Scientific, your trusted laboratory equipment partner. Our product specialists are available Monday–Friday for assistance. The MultiEX 032 is backed by a \u003cstrong\u003e2-year all-inclusive manufacturer's warranty\u003c\/strong\u003e. Contact us at \u003cstrong\u003einfo@surgescientific.com\u003c\/strong\u003e or reach out directly to our support team at \u003cstrong\u003e855.943.3344\u003c\/strong\u003e for pre-sales questions, reagent kit recommendations, protocol optimization, validation services, and technical assistance.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Four E's","offers":[{"title":"Default Title","offer_id":48229729632512,"sku":"MultiEx 032","price":5447.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/1444\/4544\/files\/MulticEX-32-1.webp?v=1777437090","url":"https:\/\/surgescientific.com\/products\/automated-nucleic-acid-extraction-multiex-032","provider":"Surge Scientific","version":"1.0","type":"link"}