{"product_id":"gentier-96e-real-time-pcr-system","title":"Gentier 96E 6 Channel 10.4'' Screen Real-Time PCR System","description":"\u003c!-- ============================================================\n     Surge Scientific — Tianlong Gentier 96E Real-Time PCR System\n     Shopify Product Description\n     Brand System : Deep Teal + Burnt Amber\n     Theme        : Athens by Truly Fine Pixels\n     Font sizing  : 100% em-based — scales with Athens Typography Scale slider\n     ============================================================ --\u003e\n\n\u003cstyle\u003e\n  :root {\n    --teal-deepest:   #0d2b2b;\n    --teal-dark:      #0d4a4a;\n    --teal-mid:       #0a7373;\n    --amber:          #bf6000;\n    --teal-light:     #e0f2f1;\n    --teal-border:    #b2dfdb;\n    --teal-pale:      #80cbc4;\n    --text-body:      #2c4a4a;\n    --text-secondary: #3a5a5a;\n    --hover-amber:    #fff8e1;\n    --white:          #ffffff;\n  }\n\n  .prod-desc {\n    font-family: 'Georgia', 'Times New Roman', serif;\n    font-size: 1em;\n    color: var(--teal-deepest);\n    width: 100%;\n    max-width: 100%;\n    box-sizing: border-box;\n    line-height: 1.7;\n  }\n\n  \/* ── 1. Hero Banner ── *\/\n  .prod-hero {\n    background: linear-gradient(135deg, #0d2b2b 0%, #0d4a4a 50%, #0a7373 100%);\n    color: var(--white);\n    padding: clamp(1.5em, 4vw, 3em) clamp(1.25em, 3vw, 2.5em);\n    border-radius: 4px;\n    margin-bottom: clamp(1.5em, 3vw, 2.5em);\n    position: relative;\n    overflow: hidden;\n    box-sizing: border-box;\n  }\n  .prod-hero::before {\n    content: '';\n    position: absolute;\n    top: -60px; right: -60px;\n    width: 220px; height: 220px;\n    border-radius: 50%;\n    background: rgba(191, 96, 0, 0.12);\n  }\n  .prod-hero::after {\n    content: '';\n    position: absolute;\n    bottom: -40px; left: 35%;\n    width: 160px; height: 160px;\n    border-radius: 50%;\n    background: rgba(224, 242, 241, 0.07);\n  }\n  .prod-hero-eyebrow {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.6875em;\n    font-weight: 700;\n    letter-spacing: 0.18em;\n    text-transform: uppercase;\n    color: var(--amber);\n    margin: 0 0 0.75em;\n  }\n  .prod-hero h1 {\n    font-family: 'Arial', sans-serif;\n    font-size: clamp(1.375em, 2.5vw, 1.875em);\n    font-weight: 800;\n    margin: 0 0 0.5em;\n    color: var(--white);\n    line-height: 1.2;\n  }\n  .prod-hero-sub {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.875em;\n    color: rgba(255,255,255,0.65);\n    margin: 0 0 1.5em;\n    letter-spacing: 0.04em;\n  }\n  .prod-hero-lead {\n    font-size: 1.0625em;\n    color: rgba(255,255,255,0.88);\n    max-width: 100%;\n    margin: 0;\n    line-height: 1.75;\n    font-style: italic;\n  }\n\n  \/* ── Section base ── *\/\n  .prod-section { margin-bottom: clamp(1.5em, 3vw, 2.5em); }\n  .prod-section-title {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.8125em;\n    font-weight: 700;\n    letter-spacing: 0.18em;\n    text-transform: uppercase;\n    color: var(--amber);\n    border-bottom: 2px solid var(--amber);\n    padding-bottom: 0.5em;\n    margin: 0 0 1.25em;\n    display: inline-block;\n  }\n  .prod-section p {\n    font-size: 1em;\n    color: var(--text-body);\n    margin: 0 0 0.875em;\n  }\n\n  \/* ── Stat Strip ── *\/\n  .prod-stats {\n    display: grid;\n    grid-template-columns: repeat(4, minmax(0, 1fr));\n    gap: clamp(0.625em, 1.5vw, 0.875em);\n    margin-bottom: clamp(1.5em, 3vw, 2.5em);\n  }\n  .prod-stat-card {\n    background: var(--teal-deepest);\n    color: var(--white);\n    padding: clamp(0.875em, 2vw, 1.25em) clamp(0.75em, 1.5vw, 1em);\n    border-radius: 4px;\n    text-align: center;\n    border-bottom: 3px solid var(--amber);\n    box-sizing: border-box;\n  }\n  .prod-stat-number {\n    font-family: 'Arial', sans-serif;\n    font-size: clamp(1.375em, 2.5vw, 1.875em);\n    font-weight: 800;\n    color: var(--amber);\n    line-height: 1.1;\n    margin: 0 0 0.25em;\n  }\n  .prod-stat-label {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.6875em;\n    font-weight: 600;\n    letter-spacing: 0.1em;\n    text-transform: uppercase;\n    color: rgba(255,255,255,0.7);\n    margin: 0;\n  }\n\n  \/* ── Value Pillars — 2×2 ── *\/\n  .prod-pillars {\n    display: grid;\n    grid-template-columns: repeat(2, minmax(0, 1fr));\n    gap: clamp(0.75em, 2vw, 1em);\n    margin-bottom: clamp(1.5em, 3vw, 2.5em);\n  }\n  .prod-pillar {\n    border: 1px solid var(--teal-border);\n    border-left: 4px solid var(--amber);\n    padding: clamp(0.875em, 2vw, 1.25em) clamp(0.75em, 1.5vw, 1.125em);\n    background: var(--teal-light);\n    border-radius: 0 4px 4px 0;\n    box-sizing: border-box;\n  }\n  .prod-pillar-icon { font-size: 1.5em; margin-bottom: 0.5em; display: block; }\n  .prod-pillar-title {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.8125em;\n    font-weight: 700;\n    text-transform: uppercase;\n    letter-spacing: 0.06em;\n    color: var(--teal-deepest);\n    margin: 0 0 0.375em;\n  }\n  .prod-pillar p {\n    font-size: 0.875em;\n    color: var(--text-secondary);\n    margin: 0;\n    line-height: 1.6;\n  }\n\n  \/* ── Callout Box ── *\/\n  .prod-callout {\n    background: linear-gradient(135deg, var(--teal-light), #f9fefe);\n    border: 1px solid var(--teal-border);\n    border-left: 5px solid var(--amber);\n    padding: clamp(0.875em, 2vw, 1.25em) clamp(0.875em, 2vw, 1.375em);\n    border-radius: 0 4px 4px 0;\n    margin-bottom: clamp(1.5em, 3vw, 2.5em);\n    box-sizing: border-box;\n  }\n  .prod-callout p {\n    font-size: 1.0625em;\n    color: var(--teal-deepest);\n    margin: 0;\n    font-style: italic;\n    line-height: 1.7;\n  }\n  .prod-callout strong { color: var(--amber); font-style: normal; }\n\n  \/* ── Feature Checklist — 2-col ── *\/\n  .prod-features {\n    list-style: none;\n    padding: 0; margin: 0 0 1em;\n    display: grid;\n    grid-template-columns: repeat(2, minmax(0, 1fr));\n    gap: 0.5em 1.5em;\n  }\n  .prod-features li {\n    font-size: 0.875em;\n    color: var(--text-body);\n    padding-left: 1.375em;\n    position: relative;\n    line-height: 1.5;\n  }\n  .prod-features li::before {\n    content: '✓';\n    position: absolute;\n    left: 0;\n    color: var(--amber);\n    font-weight: 700;\n    font-size: 1em;\n  }\n\n  \/* ── Channel Cards ── *\/\n  .prod-channels {\n    display: grid;\n    grid-template-columns: repeat(3, minmax(0, 1fr));\n    gap: clamp(0.625em, 1.5vw, 0.875em);\n    margin-bottom: clamp(1em, 2vw, 1.5em);\n  }\n  .prod-channel-card {\n    border: 1px solid var(--teal-border);\n    border-top: 3px solid var(--amber);\n    padding: clamp(0.75em, 1.5vw, 1em);\n    background: var(--teal-light);\n    border-radius: 0 0 4px 4px;\n    box-sizing: border-box;\n  }\n  .prod-channel-label {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.6875em;\n    font-weight: 700;\n    letter-spacing: 0.12em;\n    text-transform: uppercase;\n    color: var(--amber);\n    margin: 0 0 0.375em;\n  }\n  .prod-channel-name {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.8125em;\n    font-weight: 700;\n    color: var(--teal-deepest);\n    margin: 0 0 0.25em;\n  }\n  .prod-channel-dyes {\n    font-size: 0.8125em;\n    color: var(--text-secondary);\n    margin: 0;\n    line-height: 1.5;\n  }\n\n  \/* ── Use Case Cards — 3-col ── *\/\n  .prod-usecases {\n    display: grid;\n    grid-template-columns: repeat(3, minmax(0, 1fr));\n    gap: clamp(0.625em, 1.5vw, 0.875em);\n    margin-bottom: 0.5em;\n  }\n  .prod-usecase {\n    background: var(--teal-dark);\n    color: var(--white);\n    padding: clamp(0.875em, 2vw, 1.125em) clamp(0.75em, 1.5vw, 1em);\n    border-radius: 4px;\n    text-align: center;\n    box-sizing: border-box;\n  }\n  .prod-usecase-icon { font-size: 1.625em; display: block; margin-bottom: 0.5em; }\n  .prod-usecase-title {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.75em;\n    font-weight: 700;\n    letter-spacing: 0.06em;\n    text-transform: uppercase;\n    color: var(--amber);\n    margin-bottom: 0.375em;\n  }\n  .prod-usecase p {\n    font-size: 0.8125em;\n    color: rgba(255,255,255,0.75);\n    margin: 0;\n    line-height: 1.5;\n  }\n\n  \/* ── Connectivity Badges ── *\/\n  .prod-badges {\n    display: flex;\n    flex-wrap: wrap;\n    gap: 0.625em;\n    margin-top: 0.75em;\n  }\n  .prod-badge {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.6875em;\n    font-weight: 700;\n    letter-spacing: 0.06em;\n    text-transform: uppercase;\n    background: var(--teal-dark);\n    color: var(--white);\n    padding: 0.4em 0.75em;\n    border-radius: 2px;\n  }\n  .prod-badge.amber { background: var(--amber); }\n  .prod-badge.outline {\n    background: transparent;\n    color: var(--teal-dark);\n    border: 1.5px solid var(--teal-dark);\n  }\n\n  \/* ── Specs Table ── *\/\n  .prod-specs-wrap {\n    width: 100%;\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n    margin-bottom: 0.5em;\n  }\n  .prod-specs-table {\n    width: 100%;\n    min-width: 480px;\n    border-collapse: collapse;\n    font-size: 0.875em;\n    font-family: 'Arial', sans-serif;\n  }\n  .prod-specs-table thead tr { background: var(--teal-dark); color: var(--white); }\n  .prod-specs-table thead th {\n    padding: clamp(0.5em, 1.2vw, 0.625em) clamp(0.625em, 1.5vw, 0.875em);\n    text-align: left;\n    font-size: 0.6875em;\n    letter-spacing: 0.12em;\n    text-transform: uppercase;\n    white-space: nowrap;\n  }\n  .prod-specs-table tbody tr:nth-child(even) { background: var(--teal-light); }\n  .prod-specs-table tbody tr:hover { background: var(--hover-amber); }\n  .prod-specs-table td {\n    padding: clamp(0.5em, 1vw, 0.5625em) clamp(0.625em, 1.5vw, 0.875em);\n    border-bottom: 1px solid var(--teal-border);\n    color: var(--text-body);\n    vertical-align: top;\n  }\n  .prod-specs-table td:first-child {\n    font-weight: 600;\n    color: var(--teal-deepest);\n    width: 32%;\n  }\n  .prod-specs-table .section-header td {\n    background: var(--teal-deepest);\n    color: var(--amber);\n    font-family: 'Arial', sans-serif;\n    font-size: 0.6875em;\n    font-weight: 700;\n    letter-spacing: 0.14em;\n    text-transform: uppercase;\n    padding: 0.5em clamp(0.625em, 1.5vw, 0.875em);\n  }\n\n  \/* ── Warranty Strip ── *\/\n  .prod-warranty {\n    background: linear-gradient(135deg, #0a7373, #0d4a4a);\n    color: var(--white);\n    padding: clamp(0.875em, 2vw, 1em) clamp(1em, 2.5vw, 1.5em);\n    border-radius: 4px;\n    display: flex;\n    align-items: flex-start;\n    gap: 0.875em;\n    margin-top: clamp(1.5em, 3vw, 2.5em);\n    box-sizing: border-box;\n  }\n  .prod-warranty-icon { font-size: 1.75em; flex-shrink: 0; margin-top: 0.125em; }\n  .prod-warranty p { margin: 0; font-size: 0.875em; line-height: 1.5; }\n  .prod-warranty strong { color: var(--amber); }\n\n  \/* ── Responsive ── *\/\n  @media (max-width: 600px) {\n    .prod-usecases,\n    .prod-channels { grid-template-columns: 1fr; }\n    .prod-stats { grid-template-columns: repeat(2, minmax(0, 1fr)); }\n  }\n  @media (max-width: 480px) {\n    .prod-pillars,\n    .prod-features { grid-template-columns: 1fr; }\n    .prod-hero h1 { font-size: 1.25em; }\n    .prod-stats { grid-template-columns: repeat(2, minmax(0, 1fr)); }\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"prod-desc\"\u003e\n\n  \u003c!-- ── 1. HERO BANNER ── --\u003e\n  \u003cdiv class=\"prod-hero\"\u003e\n    \u003cp class=\"prod-hero-eyebrow\"\u003eSurge Scientific · Tianlong Gentier 96E · IVDR CE Certified\u003c\/p\u003e\n    \u003ch1\u003eGentier 96E Real-Time PCR System\u003c\/h1\u003e\n    \u003cp class=\"prod-hero-sub\"\u003e96 Wells · 6 Fluorescence Channels · 7-Second Full-Plate Scan · ±0.1°C Uniformity · 10.4\" Touch Screen\u003c\/p\u003e\n    \u003cp class=\"prod-hero-lead\"\u003e\n      Most 96-well qPCR platforms make you choose between throughput and optical precision — slower scanning means more stable readings, or so the assumption goes. The Gentier 96E disproves that trade-off: \u003cstrong\u003eall 96 wells across all 6 fluorescence channels are scanned in 7 seconds\u003c\/strong\u003e, while ±0.1°C block uniformity and Peltier-driven ramp rates above 6.1°C\/s ensure that speed never comes at the expense of thermal accuracy.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── KEY STATS STRIP ── --\u003e\n  \u003cdiv class=\"prod-stats\"\u003e\n    \u003cdiv class=\"prod-stat-card\"\u003e\n      \u003cp class=\"prod-stat-number\"\u003e7s\u003c\/p\u003e\n      \u003cp class=\"prod-stat-label\"\u003eFull 96-Well Scan\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-stat-card\"\u003e\n      \u003cp class=\"prod-stat-number\"\u003e6\u003c\/p\u003e\n      \u003cp class=\"prod-stat-label\"\u003eFluorescence Channels\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-stat-card\"\u003e\n      \u003cp class=\"prod-stat-number\"\u003e\u0026gt;6.1°C\/s\u003c\/p\u003e\n      \u003cp class=\"prod-stat-label\"\u003eMax Heating Rate\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-stat-card\"\u003e\n      \u003cp class=\"prod-stat-number\"\u003e±0.1°C\u003c\/p\u003e\n      \u003cp class=\"prod-stat-label\"\u003eBlock Uniformity\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 2. WHY qPCR SPEED AND THERMAL ACCURACY BOTH MATTER ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eWhy Speed Without Uniformity is Useless in qPCR\u003c\/p\u003e\n    \u003cp\u003e\n      Fluorescence scanning speed and thermal block performance are the two parameters most labs examine separately — but they fail or succeed together. A fast scanner on a thermally uneven block amplifies the unevenness: the wells that heat faster reach denaturation first, those that cool slower anneal late, and what looks like biological variation in your Ct values is actually instrument artifact. This is the hidden source of CV inflation in multi-well quantification runs, and it becomes especially damaging in multiplex panels where channel cross-talk compounds block non-uniformity.\n    \u003c\/p\u003e\n    \u003cp\u003e\n      The Gentier 96E addresses both vectors simultaneously. The Peltier-based thermal block delivers \u003cstrong\u003e±0.1°C uniformity across all 96 wells\u003c\/strong\u003e — not edge-compensated, not software-corrected, but physically uniform — while the top-scanning LED\/photodiode optical system completes a full-plate fluorescence read in 7 seconds without edge effects. The result is a Ct CV of ≤0.5% and a linear correlation coefficient of |r| ≥ 0.999, across a 10-log dynamic range from 10¹ to 10¹⁰ copies.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 3. FOUR VALUE PILLARS ── --\u003e\n  \u003cdiv class=\"prod-pillars\"\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e⚡\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003e7-Second Full-Plate Optical Scan\u003c\/p\u003e\n      \u003cp\u003eSimultaneous well-by-well scanning of all fluorescence channels completes in \u003cstrong\u003e7 seconds for all 96 wells\u003c\/strong\u003e — eliminating edge effects from sequential scanning and reducing total run time without sacrificing signal integrity. LED excitation from the top ensures consistent optical path geometry across every well position.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e🌡️\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003ePeltier Thermal Block Precision\u003c\/p\u003e\n      \u003cp\u003eA maximum heating ramp rate of \u003cstrong\u003e\u0026gt;6.1°C\/s\u003c\/strong\u003e and cooling rate of \u003cstrong\u003e\u0026gt;5.0°C\/s\u003c\/strong\u003e with ±0.1°C block uniformity and ≤0.1°C accuracy. Supports 12-column gradient PCR (1°C–40°C range), Touch Down PCR, and long PCR protocols — all from a single instrument without hardware swaps.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e🖥️\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003eDual-Mode Standalone Operation\u003c\/p\u003e\n      \u003cp\u003eA \u003cstrong\u003e10.4-inch full-color touchscreen\u003c\/strong\u003e enables complete instrument control without a connected PC — run protocols, review results, and manage up to 1,000 stored experiments independently. Power-failure protection automatically resumes interrupted runs when power is restored, with no software intervention required.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e🔬\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003eBroad Dye Compatibility Across 6 Channels\u003c\/p\u003e\n      \u003cp\u003eSix fluorescence channels covering FAM\/SYBR Green through FRET accommodate virtually every probe chemistry in current clinical and research use — including \u003cstrong\u003eHEX\/VIC, ROX, Cy5, and Alexa Fluor 680\u003c\/strong\u003e. Channel configurations match Bio-Rad CFX96 and Agilent Mx3005P layouts for seamless assay transfer.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 4. CALLOUT BOX ── --\u003e\n  \u003cdiv class=\"prod-callout\"\u003e\n    \u003cp\u003e\n      \u003cstrong\u003eCt CV ≤ 0.5% · Linear correlation |r| ≥ 0.999 · 10-log dynamic range.\u003c\/strong\u003e These are not marketing claims — they are the repeatability and linearity thresholds required for IVDR CE certification and validated across the Gentier 96E's full 10¹ to 10¹⁰ copy dynamic range, using Ct value coefficient of variation as the primary acceptance criterion.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 5. KEY FEATURES ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eKey Features\u003c\/p\u003e\n    \u003cul class=\"prod-features\"\u003e\n      \u003cli\u003e96-well throughput — 1 to 96 samples per run\u003c\/li\u003e\n      \u003cli\u003eFull-plate fluorescence scan in 7 seconds flat\u003c\/li\u003e\n      \u003cli\u003e6 fluorescence detection channels\u003c\/li\u003e\n      \u003cli\u003eLED light source — high-brightness, maintenance-free\u003c\/li\u003e\n      \u003cli\u003ePhotodiode (PD) detector, top-scanning architecture\u003c\/li\u003e\n      \u003cli\u003eNo edge effects — simultaneous well-by-well detection\u003c\/li\u003e\n      \u003cli\u003ePeltier heating\/cooling — \u0026gt;6.1°C\/s heating, \u0026gt;5.0°C\/s cooling\u003c\/li\u003e\n      \u003cli\u003eBlock uniformity: ±0.1°C across all 96 wells\u003c\/li\u003e\n      \u003cli\u003eTemperature accuracy: ≤0.1°C\u003c\/li\u003e\n      \u003cli\u003eGradient PCR: 12-column, 1°C–40°C range\u003c\/li\u003e\n      \u003cli\u003eTouch Down PCR and Long PCR protocol support\u003c\/li\u003e\n      \u003cli\u003e10.4-inch full-color touchscreen — standalone operation\u003c\/li\u003e\n      \u003cli\u003ePC software control via direct USB connection\u003c\/li\u003e\n      \u003cli\u003ePower-failure auto-recovery — no data loss\u003c\/li\u003e\n      \u003cli\u003eStores up to 1,000 experimental results on-board\u003c\/li\u003e\n      \u003cli\u003eUSB data upload\/download — no network required\u003c\/li\u003e\n      \u003cli\u003eAbsolute \u0026amp; relative quantification analysis\u003c\/li\u003e\n      \u003cli\u003eSNP genotyping analysis\u003c\/li\u003e\n      \u003cli\u003eMelting curve \/ dissociation curve analysis\u003c\/li\u003e\n      \u003cli\u003eCustomizable experiment report templates\u003c\/li\u003e\n      \u003cli\u003eCompatible: 0.2mL 96-well plates, 8-tube strips, single tubes\u003c\/li\u003e\n      \u003cli\u003eFluorescence dynamic range: adjustable gain\u003c\/li\u003e\n      \u003cli\u003eSample dynamic range: 10¹ to 10¹⁰ copies\u003c\/li\u003e\n      \u003cli\u003eIVDR CE certified · EU RoHS compliant · NMPA registered\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 6. FLUORESCENCE CHANNEL GUIDE ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003e6-Channel Fluorescence Configuration\u003c\/p\u003e\n    \u003cp\u003eThe Gentier 96E's optical system covers the full range of probe chemistries used in clinical diagnostics, infectious disease testing, oncology panels, and molecular research — including both hydrolysis probe and intercalating dye formats.\u003c\/p\u003e\n    \u003cdiv class=\"prod-channels\"\u003e\n      \u003cdiv class=\"prod-channel-card\"\u003e\n        \u003cp class=\"prod-channel-label\"\u003eChannel 1 · 465nm \/ 510nm\u003c\/p\u003e\n        \u003cp class=\"prod-channel-name\"\u003eFAM \/ SYBR Green I\u003c\/p\u003e\n        \u003cp class=\"prod-channel-dyes\"\u003eFAM · SYBR Green I · SYTO 9 · Eva Green · LC Green\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-channel-card\"\u003e\n        \u003cp class=\"prod-channel-label\"\u003eChannel 2 · 527nm \/ 563nm\u003c\/p\u003e\n        \u003cp class=\"prod-channel-name\"\u003eHEX \/ VIC\u003c\/p\u003e\n        \u003cp class=\"prod-channel-dyes\"\u003eHEX · VIC · TET · JOE\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-channel-card\"\u003e\n        \u003cp class=\"prod-channel-label\"\u003eChannel 3 · 580nm \/ 616nm\u003c\/p\u003e\n        \u003cp class=\"prod-channel-name\"\u003eROX \/ Texas Red\u003c\/p\u003e\n        \u003cp class=\"prod-channel-dyes\"\u003eROX · Texas Red\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-channel-card\"\u003e\n        \u003cp class=\"prod-channel-label\"\u003eChannel 4 · 632nm \/ 664nm\u003c\/p\u003e\n        \u003cp class=\"prod-channel-name\"\u003eCy5\u003c\/p\u003e\n        \u003cp class=\"prod-channel-dyes\"\u003eCy5\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-channel-card\"\u003e\n        \u003cp class=\"prod-channel-label\"\u003eChannel 5 · 680nm \/ 730nm\u003c\/p\u003e\n        \u003cp class=\"prod-channel-name\"\u003eAlexa Fluor 680\u003c\/p\u003e\n        \u003cp class=\"prod-channel-dyes\"\u003eAlexa Fluor 680\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-channel-card\"\u003e\n        \u003cp class=\"prod-channel-label\"\u003eChannel 6 · 465nm \/ 616nm\u003c\/p\u003e\n        \u003cp class=\"prod-channel-name\"\u003eFRET\u003c\/p\u003e\n        \u003cp class=\"prod-channel-dyes\"\u003eFRET probes\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 7. IDEAL APPLICATIONS ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eIdeal Applications\u003c\/p\u003e\n    \u003cdiv class=\"prod-usecases\"\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e🏥\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003eClinical Diagnostics\u003c\/p\u003e\n        \u003cp\u003eInfectious pathogen detection (viral, bacterial, mycoplasma, chlamydia), blood screening, viral hepatitis quantification, STI panels, and oncology biomarker testing in hospital and clinical reference labs.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e🧬\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003eMolecular Research\u003c\/p\u003e\n        \u003cp\u003eAbsolute and relative gene expression quantification, SNP genotyping, melting curve analysis, and high-throughput screening in genomics, immunology, forensics, and pharmacogenomics research workflows.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e🌿\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003eFood, Vet \u0026amp; Environmental\u003c\/p\u003e\n        \u003cp\u003eFood pathogen and GMO detection, animal disease surveillance (avian influenza, ASF, FMD), environmental health monitoring, and agricultural pathogen screening at CDC and inspection bureau laboratories.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 8. CONNECTIVITY \u0026 INTEGRATION ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eConnectivity \u0026amp; Compatibility\u003c\/p\u003e\n    \u003cp\u003eThe Gentier 96E operates as a fully standalone instrument or under PC software control — with data transfer, consumable flexibility, and software compatibility designed for integration into existing lab workflows without infrastructure changes.\u003c\/p\u003e\n    \u003cdiv class=\"prod-badges\"\u003e\n      \u003cspan class=\"prod-badge amber\"\u003e10.4\" Touch Screen\u003c\/span\u003e\n      \u003cspan class=\"prod-badge amber\"\u003ePC Software Control\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003eUSB Data Transfer\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003e1,000 Results On-Board\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003eWin 7 \/ 10 \/ 11\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003e96-Well Plates\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003e8-Tube Strips\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003eSingle Tubes (Clear \/ White)\u003c\/span\u003e\n      \u003cspan class=\"prod-badge outline\"\u003eIVDR CE Certified\u003c\/span\u003e\n      \u003cspan class=\"prod-badge outline\"\u003eEU RoHS Compliant\u003c\/span\u003e\n      \u003cspan class=\"prod-badge outline\"\u003eNMPA Registered\u003c\/span\u003e\n      \u003cspan class=\"prod-badge outline\"\u003eAC 100–240V Universal\u003c\/span\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 9. TECHNICAL SPECIFICATIONS ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eTechnical Specifications\u003c\/p\u003e\n    \u003cdiv class=\"prod-specs-wrap\"\u003e\n      \u003ctable class=\"prod-specs-table\"\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr class=\"section-header\"\u003e\u003ctd colspan=\"2\"\u003eSample \u0026amp; Throughput\u003c\/td\u003e\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGentier 96E\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSample Throughput\u003c\/td\u003e\n\u003ctd\u003e1–96 wells per run\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSuitable Consumables\u003c\/td\u003e\n\u003ctd\u003e0.2mL 96-well plates · 8-tube strips · single tubes (clear, frosted, white)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSample Dynamic Range\u003c\/td\u003e\n\u003ctd\u003e10¹ to 10¹⁰ copies\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eLinearity (|r|)\u003c\/td\u003e\n\u003ctd\u003e≥ 0.999\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eRepeatability (Ct CV)\u003c\/td\u003e\n\u003ctd\u003e≤ 0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr class=\"section-header\"\u003e\u003ctd colspan=\"2\"\u003eOptical System\u003c\/td\u003e\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eFluorescence Channels\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eFluorescence Scanning Time\u003c\/td\u003e\n\u003ctd\u003e7 seconds (all 96 wells, all channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDetection Method\u003c\/td\u003e\n\u003ctd\u003eSimultaneous well-by-well scanning — no edge effects\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eHigh-brightness, long-life, maintenance-free LED · top excitation\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDetector\u003c\/td\u003e\n\u003ctd\u003ePhotodiodes (PDs) · top scanning\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eFluorescence Dynamic Range\u003c\/td\u003e\n\u003ctd\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eExcitation Wavelengths\u003c\/td\u003e\n\u003ctd\u003eCH1: 465nm · CH2: 527nm · CH3: 580nm · CH4: 632nm · CH5: 680nm · CH6: 465nm\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDetection Wavelengths\u003c\/td\u003e\n\u003ctd\u003eCH1: 510nm · CH2: 563nm · CH3: 616nm · CH4: 664nm · CH5: 730nm · CH6: 616nm\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDye Compatibility\u003c\/td\u003e\n\u003ctd\u003eCH1: FAM, SYBR Green I, SYTO 9, Eva Green, LC Green · CH2: HEX, VIC, TET, JOE · CH3: ROX, Texas Red · CH4: Cy5 · CH5: Alexa Fluor 680 · CH6: FRET\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr class=\"section-header\"\u003e\u003ctd colspan=\"2\"\u003eThermal Block\u003c\/td\u003e\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eHeating Method\u003c\/td\u003e\n\u003ctd\u003ePeltier\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eHeating Rate\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 6.1°C\/s (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCooling Rate\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 5.0°C\/s (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eTemperature Uniformity\u003c\/td\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e≤ 0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eGradient Range\u003c\/td\u003e\n\u003ctd\u003e1°C – 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eGradient Block\u003c\/td\u003e\n\u003ctd\u003e12 columns\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSpecial PCR Protocols\u003c\/td\u003e\n\u003ctd\u003eGradient PCR · Touch Down PCR · Long PCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr class=\"section-header\"\u003e\u003ctd colspan=\"2\"\u003eSoftware \u0026amp; Control\u003c\/td\u003e\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eControl Mode 1\u003c\/td\u003e\n\u003ctd\u003e10.4-inch full-color touch screen (standalone)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eControl Mode 2\u003c\/td\u003e\n\u003ctd\u003ePC direct control via software\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePC Operating System\u003c\/td\u003e\n\u003ctd\u003eWindows 7 \/ 10 \/ 11\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eData Storage\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 experimental results stored on-board\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eData Transfer\u003c\/td\u003e\n\u003ctd\u003eUSB disk upload\/download\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePower Failure Protection\u003c\/td\u003e\n\u003ctd\u003eAutomatic experiment recovery on power restore — no PC required\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eReporting\u003c\/td\u003e\n\u003ctd\u003eCustomizable experiment report templates\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eAnalysis Functions\u003c\/td\u003e\n\u003ctd\u003eAbsolute quantification · Relative quantification · SNP analysis · Melting curve analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr class=\"section-header\"\u003e\u003ctd colspan=\"2\"\u003ePhysical \u0026amp; Electrical\u003c\/td\u003e\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDimensions (W×L×H)\u003c\/td\u003e\n\u003ctd\u003e555 × 475 × 484 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eWeight (Net)\u003c\/td\u003e\n\u003ctd\u003e30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eAC 100–240V, 50–60Hz · 900 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eIVDR CE · NMPA · EU RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 10. WARRANTY \u0026 SUPPORT ── --\u003e\n  \u003cdiv class=\"prod-warranty\"\u003e\n    \u003cspan class=\"prod-warranty-icon\"\u003e🛡️\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cp\u003e\u003cstrong\u003eSurge Scientific Warranty \u0026amp; Support\u003c\/strong\u003e\u003c\/p\u003e\n      \u003cp\u003eThe Gentier 96E is sold through Surge Scientific, your trusted laboratory instrument partner. Our product specialists are available Monday–Friday for pre-sales questions, assay compatibility guidance, and technical support. This instrument is backed by a \u003cstrong\u003e2-year all-inclusive manufacturer's warranty\u003c\/strong\u003e. Contact us at \u003cstrong\u003einfo@surgescientific.com\u003c\/strong\u003e or call \u003cstrong\u003e855.943.3344\u003c\/strong\u003e for quotes, demo requests, and application support.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Tian Long","offers":[{"title":"Default Title","offer_id":48805201903872,"sku":null,"price":18500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/1444\/4544\/files\/96e3.jpg?v=1780681111","url":"https:\/\/surgescientific.com\/products\/gentier-96e-real-time-pcr-system","provider":"Surge Scientific","version":"1.0","type":"link"}