{"product_id":"gentier-96r-4-channel-real-time-pcr-system","title":"Gentier 96R 4 Channel  Real-Time PCR System","description":"\u003c!-- ============================================================\n     Surge Scientific — Tianlong Gentier 96R Real-Time PCR System\n     Shopify Product Description\n     Brand System : Deep Teal + Burnt Amber\n     Theme        : Athens by Truly Fine Pixels\n     Font sizing  : 100% em-based — scales with Athens Typography Scale slider\n     ============================================================ --\u003e\n\n\u003cstyle\u003e\n  :root {\n    --teal-deepest:   #0d2b2b;\n    --teal-dark:      #0d4a4a;\n    --teal-mid:       #0a7373;\n    --amber:          #bf6000;\n    --teal-light:     #e0f2f1;\n    --teal-border:    #b2dfdb;\n    --teal-pale:      #80cbc4;\n    --text-body:      #2c4a4a;\n    --text-secondary: #3a5a5a;\n    --hover-amber:    #fff8e1;\n    --white:          #ffffff;\n  }\n\n  .prod-desc {\n    font-family: 'Georgia', 'Times New Roman', serif;\n    font-size: 1em;\n    color: var(--teal-deepest);\n    width: 100%;\n    max-width: 100%;\n    box-sizing: border-box;\n    line-height: 1.7;\n  }\n\n  \/* ── 1. Hero Banner ── *\/\n  .prod-hero {\n    background: linear-gradient(135deg, #0d2b2b 0%, #0d4a4a 50%, #0a7373 100%);\n    color: var(--white);\n    padding: clamp(1.5em, 4vw, 3em) clamp(1.25em, 3vw, 2.5em);\n    border-radius: 4px;\n    margin-bottom: clamp(1.5em, 3vw, 2.5em);\n    position: relative;\n    overflow: hidden;\n    box-sizing: border-box;\n  }\n  .prod-hero::before {\n    content: '';\n    position: absolute;\n    top: -60px; right: -60px;\n    width: 220px; height: 220px;\n    border-radius: 50%;\n    background: rgba(191, 96, 0, 0.12);\n  }\n  .prod-hero::after {\n    content: '';\n    position: absolute;\n    bottom: -40px; left: 35%;\n    width: 160px; height: 160px;\n    border-radius: 50%;\n    background: rgba(224, 242, 241, 0.07);\n  }\n  .prod-hero-eyebrow {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.6875em;\n    font-weight: 700;\n    letter-spacing: 0.18em;\n    text-transform: uppercase;\n    color: var(--amber);\n    margin: 0 0 0.75em;\n  }\n  .prod-hero h1 {\n    font-family: 'Arial', sans-serif;\n    font-size: clamp(1.375em, 2.5vw, 1.875em);\n    font-weight: 800;\n    margin: 0 0 0.5em;\n    color: var(--white);\n    line-height: 1.2;\n  }\n  .prod-hero-sub {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.875em;\n    color: rgba(255,255,255,0.65);\n    margin: 0 0 1.5em;\n    letter-spacing: 0.04em;\n  }\n  .prod-hero-lead {\n    font-size: 1.0625em;\n    color: rgba(255,255,255,0.88);\n    max-width: 100%;\n    margin: 0;\n    line-height: 1.75;\n    font-style: italic;\n  }\n\n  \/* ── Section base ── *\/\n  .prod-section { margin-bottom: clamp(1.5em, 3vw, 2.5em); }\n  .prod-section-title {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.8125em;\n    font-weight: 700;\n    letter-spacing: 0.18em;\n    text-transform: uppercase;\n    color: var(--amber);\n    border-bottom: 2px solid var(--amber);\n    padding-bottom: 0.5em;\n    margin: 0 0 1.25em;\n    display: inline-block;\n  }\n  .prod-section p {\n    font-size: 1em;\n    color: var(--text-body);\n    margin: 0 0 0.875em;\n  }\n\n  \/* ── Stat Strip ── *\/\n  .prod-stats {\n    display: grid;\n    grid-template-columns: repeat(4, minmax(0, 1fr));\n    gap: clamp(0.625em, 1.5vw, 0.875em);\n    margin-bottom: clamp(1.5em, 3vw, 2.5em);\n  }\n  .prod-stat-card {\n    background: var(--teal-deepest);\n    color: var(--white);\n    padding: clamp(0.875em, 2vw, 1.25em) clamp(0.75em, 1.5vw, 1em);\n    border-radius: 4px;\n    text-align: center;\n    border-bottom: 3px solid var(--amber);\n    box-sizing: border-box;\n  }\n  .prod-stat-number {\n    font-family: 'Arial', sans-serif;\n    font-size: clamp(1.375em, 2.5vw, 1.875em);\n    font-weight: 800;\n    color: var(--amber);\n    line-height: 1.1;\n    margin: 0 0 0.25em;\n  }\n  .prod-stat-label {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.6875em;\n    font-weight: 600;\n    letter-spacing: 0.1em;\n    text-transform: uppercase;\n    color: rgba(255,255,255,0.7);\n    margin: 0;\n  }\n\n  \/* ── Compat Notice ── *\/\n  .prod-compat {\n    background: var(--teal-dark);\n    border-left: 5px solid var(--amber);\n    padding: clamp(0.875em, 2vw, 1.125em) clamp(0.875em, 2vw, 1.375em);\n    border-radius: 0 4px 4px 0;\n    margin-bottom: clamp(1.5em, 3vw, 2.5em);\n    box-sizing: border-box;\n    display: flex;\n    align-items: flex-start;\n    gap: 0.75em;\n  }\n  .prod-compat-icon { font-size: 1.25em; flex-shrink: 0; margin-top: 0.1em; }\n  .prod-compat p {\n    font-size: 0.875em;\n    color: rgba(255,255,255,0.88);\n    margin: 0;\n    line-height: 1.6;\n  }\n  .prod-compat strong { color: var(--amber); }\n\n  \/* ── Value Pillars — 2×2 ── *\/\n  .prod-pillars {\n    display: grid;\n    grid-template-columns: repeat(2, minmax(0, 1fr));\n    gap: clamp(0.75em, 2vw, 1em);\n    margin-bottom: clamp(1.5em, 3vw, 2.5em);\n  }\n  .prod-pillar {\n    border: 1px solid var(--teal-border);\n    border-left: 4px solid var(--amber);\n    padding: clamp(0.875em, 2vw, 1.25em) clamp(0.75em, 1.5vw, 1.125em);\n    background: var(--teal-light);\n    border-radius: 0 4px 4px 0;\n    box-sizing: border-box;\n  }\n  .prod-pillar-icon { font-size: 1.5em; margin-bottom: 0.5em; display: block; }\n  .prod-pillar-title {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.8125em;\n    font-weight: 700;\n    text-transform: uppercase;\n    letter-spacing: 0.06em;\n    color: var(--teal-deepest);\n    margin: 0 0 0.375em;\n  }\n  .prod-pillar p {\n    font-size: 0.875em;\n    color: var(--text-secondary);\n    margin: 0;\n    line-height: 1.6;\n  }\n\n  \/* ── Callout Box ── *\/\n  .prod-callout {\n    background: linear-gradient(135deg, var(--teal-light), #f9fefe);\n    border: 1px solid var(--teal-border);\n    border-left: 5px solid var(--amber);\n    padding: clamp(0.875em, 2vw, 1.25em) clamp(0.875em, 2vw, 1.375em);\n    border-radius: 0 4px 4px 0;\n    margin-bottom: clamp(1.5em, 3vw, 2.5em);\n    box-sizing: border-box;\n  }\n  .prod-callout p {\n    font-size: 1.0625em;\n    color: var(--teal-deepest);\n    margin: 0;\n    font-style: italic;\n    line-height: 1.7;\n  }\n  .prod-callout strong { color: var(--amber); font-style: normal; }\n\n  \/* ── Feature Checklist — 2-col ── *\/\n  .prod-features {\n    list-style: none;\n    padding: 0; margin: 0 0 1em;\n    display: grid;\n    grid-template-columns: repeat(2, minmax(0, 1fr));\n    gap: 0.5em 1.5em;\n  }\n  .prod-features li {\n    font-size: 0.875em;\n    color: var(--text-body);\n    padding-left: 1.375em;\n    position: relative;\n    line-height: 1.5;\n  }\n  .prod-features li::before {\n    content: '✓';\n    position: absolute;\n    left: 0;\n    color: var(--amber);\n    font-weight: 700;\n    font-size: 1em;\n  }\n\n  \/* ── Channel Cards — 4 in a row ── *\/\n  .prod-channels {\n    display: grid;\n    grid-template-columns: repeat(4, minmax(0, 1fr));\n    gap: clamp(0.625em, 1.5vw, 0.875em);\n    margin-bottom: clamp(1em, 2vw, 1.5em);\n  }\n  .prod-channel-card {\n    border: 1px solid var(--teal-border);\n    border-top: 3px solid var(--amber);\n    padding: clamp(0.75em, 1.5vw, 1em);\n    background: var(--teal-light);\n    border-radius: 0 0 4px 4px;\n    box-sizing: border-box;\n  }\n  .prod-channel-label {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.6875em;\n    font-weight: 700;\n    letter-spacing: 0.12em;\n    text-transform: uppercase;\n    color: var(--amber);\n    margin: 0 0 0.375em;\n  }\n  .prod-channel-name {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.8125em;\n    font-weight: 700;\n    color: var(--teal-deepest);\n    margin: 0 0 0.25em;\n  }\n  .prod-channel-dyes {\n    font-size: 0.8125em;\n    color: var(--text-secondary);\n    margin: 0;\n    line-height: 1.5;\n  }\n\n  \/* ── Use Case Cards — 3-col ── *\/\n  .prod-usecases {\n    display: grid;\n    grid-template-columns: repeat(3, minmax(0, 1fr));\n    gap: clamp(0.625em, 1.5vw, 0.875em);\n    margin-bottom: 0.5em;\n  }\n  .prod-usecase {\n    background: var(--teal-dark);\n    color: var(--white);\n    padding: clamp(0.875em, 2vw, 1.125em) clamp(0.75em, 1.5vw, 1em);\n    border-radius: 4px;\n    text-align: center;\n    box-sizing: border-box;\n  }\n  .prod-usecase-icon { font-size: 1.625em; display: block; margin-bottom: 0.5em; }\n  .prod-usecase-title {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.75em;\n    font-weight: 700;\n    letter-spacing: 0.06em;\n    text-transform: uppercase;\n    color: var(--amber);\n    margin-bottom: 0.375em;\n  }\n  .prod-usecase p {\n    font-size: 0.8125em;\n    color: rgba(255,255,255,0.75);\n    margin: 0;\n    line-height: 1.5;\n  }\n\n  \/* ── Connectivity Badges ── *\/\n  .prod-badges {\n    display: flex;\n    flex-wrap: wrap;\n    gap: 0.625em;\n    margin-top: 0.75em;\n  }\n  .prod-badge {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.6875em;\n    font-weight: 700;\n    letter-spacing: 0.06em;\n    text-transform: uppercase;\n    background: var(--teal-dark);\n    color: var(--white);\n    padding: 0.4em 0.75em;\n    border-radius: 2px;\n  }\n  .prod-badge.amber { background: var(--amber); }\n  .prod-badge.outline {\n    background: transparent;\n    color: var(--teal-dark);\n    border: 1.5px solid var(--teal-dark);\n  }\n\n  \/* ── Specs Table ── *\/\n  .prod-specs-wrap {\n    width: 100%;\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n    margin-bottom: 0.5em;\n  }\n  .prod-specs-table {\n    width: 100%;\n    min-width: 480px;\n    border-collapse: collapse;\n    font-size: 0.875em;\n    font-family: 'Arial', sans-serif;\n  }\n  .prod-specs-table thead tr { background: var(--teal-dark); color: var(--white); }\n  .prod-specs-table thead th {\n    padding: clamp(0.5em, 1.2vw, 0.625em) clamp(0.625em, 1.5vw, 0.875em);\n    text-align: left;\n    font-size: 0.6875em;\n    letter-spacing: 0.12em;\n    text-transform: uppercase;\n    white-space: nowrap;\n  }\n  .prod-specs-table tbody tr:nth-child(even) { background: var(--teal-light); }\n  .prod-specs-table tbody tr:hover { background: var(--hover-amber); }\n  .prod-specs-table td {\n    padding: clamp(0.5em, 1vw, 0.5625em) clamp(0.625em, 1.5vw, 0.875em);\n    border-bottom: 1px solid var(--teal-border);\n    color: var(--text-body);\n    vertical-align: top;\n  }\n  .prod-specs-table td:first-child {\n    font-weight: 600;\n    color: var(--teal-deepest);\n    width: 32%;\n  }\n  .prod-specs-table .section-header td {\n    background: var(--teal-deepest);\n    color: var(--amber);\n    font-family: 'Arial', sans-serif;\n    font-size: 0.6875em;\n    font-weight: 700;\n    letter-spacing: 0.14em;\n    text-transform: uppercase;\n    padding: 0.5em clamp(0.625em, 1.5vw, 0.875em);\n  }\n\n  \/* ── Warranty Strip ── *\/\n  .prod-warranty {\n    background: linear-gradient(135deg, #0a7373, #0d4a4a);\n    color: var(--white);\n    padding: clamp(0.875em, 2vw, 1em) clamp(1em, 2.5vw, 1.5em);\n    border-radius: 4px;\n    display: flex;\n    align-items: flex-start;\n    gap: 0.875em;\n    margin-top: clamp(1.5em, 3vw, 2.5em);\n    box-sizing: border-box;\n  }\n  .prod-warranty-icon { font-size: 1.75em; flex-shrink: 0; margin-top: 0.125em; }\n  .prod-warranty p { margin: 0; font-size: 0.875em; line-height: 1.5; }\n  .prod-warranty strong { color: var(--amber); }\n\n  \/* ── Responsive ── *\/\n  @media (max-width: 700px) {\n    .prod-channels { grid-template-columns: repeat(2, minmax(0, 1fr)); }\n  }\n  @media (max-width: 600px) {\n    .prod-usecases { grid-template-columns: 1fr; }\n    .prod-stats { grid-template-columns: repeat(2, minmax(0, 1fr)); }\n  }\n  @media (max-width: 480px) {\n    .prod-pillars,\n    .prod-features { grid-template-columns: 1fr; }\n    .prod-hero h1 { font-size: 1.25em; }\n    .prod-channels { grid-template-columns: 1fr; }\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"prod-desc\"\u003e\n\n  \u003c!-- ── 1. HERO BANNER ── --\u003e\n  \u003cdiv class=\"prod-hero\"\u003e\n    \u003cp class=\"prod-hero-eyebrow\"\u003eSurge Scientific · Tianlong Gentier 96R · IVDR CE Certified\u003c\/p\u003e\n    \u003ch1\u003eGentier 96R Real-Time PCR System\u003c\/h1\u003e\n    \u003cp class=\"prod-hero-sub\"\u003e96 Wells · 4 Fluorescence Channels · 7-Second Full-Plate Scan · ±0.1°C Uniformity · Standalone Touchscreen\u003c\/p\u003e\n    \u003cp class=\"prod-hero-lead\"\u003e\n      The majority of clinical and research qPCR assays run on four dye channels — FAM, HEX\/VIC, ROX, and Cy5. The Gentier 96R is built precisely around that reality: \u003cstrong\u003efour optimized fluorescence channels\u003c\/strong\u003e covering every major probe chemistry in current diagnostic and research use, paired with the same Peltier thermal block and 7-second full-plate scanning engine that drives the 96E — at a configuration matched to how most labs actually run their panels.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── KEY STATS STRIP ── --\u003e\n  \u003cdiv class=\"prod-stats\"\u003e\n    \u003cdiv class=\"prod-stat-card\"\u003e\n      \u003cp class=\"prod-stat-number\"\u003e7s\u003c\/p\u003e\n      \u003cp class=\"prod-stat-label\"\u003eFull 96-Well Scan\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-stat-card\"\u003e\n      \u003cp class=\"prod-stat-number\"\u003e4\u003c\/p\u003e\n      \u003cp class=\"prod-stat-label\"\u003eFluorescence Channels\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-stat-card\"\u003e\n      \u003cp class=\"prod-stat-number\"\u003e\u0026gt;6.1°C\/s\u003c\/p\u003e\n      \u003cp class=\"prod-stat-label\"\u003eMax Heating Rate\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-stat-card\"\u003e\n      \u003cp class=\"prod-stat-number\"\u003e±0.1°C\u003c\/p\u003e\n      \u003cp class=\"prod-stat-label\"\u003eBlock Uniformity\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── INSTRUMENT COMPATIBILITY NOTICE ── --\u003e\n  \u003cdiv class=\"prod-compat\"\u003e\n    \u003cspan class=\"prod-compat-icon\"\u003e🔁\u003c\/span\u003e\n    \u003cp\u003e\n      \u003cstrong\u003eDrop-in compatible with Bio-Rad CFX96 assay panels.\u003c\/strong\u003e The Gentier 96R's 4-channel optical configuration — FAM, HEX\/VIC, ROX, Texas Red, Cy5 — mirrors the CFX96 channel layout. Assays validated on the CFX96 transfer to the 96R without re-optimization, making it the lowest-friction upgrade path for labs standardizing on a cost-efficient high-throughput platform.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 2. WHY 4-CHANNEL IS THE RIGHT CONFIGURATION FOR MOST LABS ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eWhy Four Channels Cover the Full Diagnostic Spectrum\u003c\/p\u003e\n    \u003cp\u003e\n      The diagnostic PCR market runs predominantly on four dye channels. FAM anchors the primary target in virtually every clinical assay — from SARS-CoV-2 to HPV to MRSA. The second channel (HEX\/VIC) carries the internal control in singleplex formats or the second target in duplex panels. ROX serves as the passive reference in most thermocycler platforms, and Cy5 handles the fourth target in multiplex infectious disease panels or the second probe in SNP genotyping. Labs that pay for a sixth channel and use it for two runs per year are over-instrumenting for a workflow that doesn't require it.\n    \u003c\/p\u003e\n    \u003cp\u003e\n      The Gentier 96R delivers the \u003cstrong\u003esame Peltier thermal block, the same 7-second LED\/photodiode scan architecture, and the same ±0.1°C uniformity\u003c\/strong\u003e as the 96E — optimized to four channels that cover 95% of published clinical qPCR assay formats. The result is full-platform performance tuned precisely to the workload of clinical diagnostics, infectious disease testing, and standard molecular research panels.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 3. FOUR VALUE PILLARS ── --\u003e\n  \u003cdiv class=\"prod-pillars\"\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e⚡\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003e7-Second Full-Plate Scan, No Edge Effects\u003c\/p\u003e\n      \u003cp\u003eThe top-scanning LED\/photodiode optical system scans all 96 wells across all 4 channels in \u003cstrong\u003e7 seconds\u003c\/strong\u003e — simultaneous well-by-well detection eliminates the position-dependent signal variation that plagues sequential scanning systems. Every well in every row sees the same optical geometry, at the same moment in the thermal cycle.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e🌡️\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003ePeltier Block — Precision at Scale\u003c\/p\u003e\n      \u003cp\u003eA maximum heating rate of \u003cstrong\u003e\u0026gt;6.1°C\/s\u003c\/strong\u003e and cooling rate of \u003cstrong\u003e\u0026gt;5.0°C\/s\u003c\/strong\u003e keep thermal cycling tight across all 96 wells simultaneously. ±0.1°C block uniformity and ≤0.1°C temperature accuracy translate directly to Ct CV ≤0.5% — the repeatability benchmark required for validated clinical assay performance.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e🖥️\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003eStandalone Operation Without PC Dependency\u003c\/p\u003e\n      \u003cp\u003eA \u003cstrong\u003e10.4-inch full-color touchscreen\u003c\/strong\u003e runs protocols, stores up to 1,000 results, and manages all instrument functions independently. Power-failure protection resumes interrupted experiments automatically — no PC reboot, no software restart, no lost run — making the 96R reliable in environments where IT infrastructure is inconsistent.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e📊\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003eComplete Analysis Suite, On-Board\u003c\/p\u003e\n      \u003cp\u003eAbsolute quantification, relative quantification, SNP genotyping, and melting curve analysis are all available directly on the instrument — no external software license required for routine workflows. \u003cstrong\u003eCustomizable report templates\u003c\/strong\u003e output publication-ready or regulatory-submission-ready data in a single export step.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 4. CALLOUT BOX ── --\u003e\n  \u003cdiv class=\"prod-callout\"\u003e\n    \u003cp\u003e\n      \u003cstrong\u003e|r| ≥ 0.999 linear correlation · Ct CV ≤ 0.5% · 10¹ to 10¹⁰ copy dynamic range.\u003c\/strong\u003e The Gentier 96R's validated performance parameters satisfy the quantification accuracy and repeatability requirements of IVDR CE certification — the same regulatory standard applied to in vitro diagnostic instruments in the European market.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 5. KEY FEATURES ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eKey Features\u003c\/p\u003e\n    \u003cul class=\"prod-features\"\u003e\n      \u003cli\u003e96-well throughput — 1 to 96 samples per run\u003c\/li\u003e\n      \u003cli\u003eComplete 96-well fluorescence scan in 7 seconds\u003c\/li\u003e\n      \u003cli\u003e4 optimized fluorescence detection channels\u003c\/li\u003e\n      \u003cli\u003eHigh-brightness, maintenance-free LED light source\u003c\/li\u003e\n      \u003cli\u003ePhotodiode (PD) detector — top-scanning architecture\u003c\/li\u003e\n      \u003cli\u003eSimultaneous well-by-well detection — zero edge effects\u003c\/li\u003e\n      \u003cli\u003ePeltier heating: \u0026gt;6.1°C\/s · Cooling: \u0026gt;5.0°C\/s\u003c\/li\u003e\n      \u003cli\u003eBlock uniformity: ±0.1°C across all 96 wells\u003c\/li\u003e\n      \u003cli\u003eTemperature accuracy: ≤0.1°C\u003c\/li\u003e\n      \u003cli\u003eGradient PCR: 12 columns, 1°C–40°C range\u003c\/li\u003e\n      \u003cli\u003eTouch Down PCR and Long PCR protocol support\u003c\/li\u003e\n      \u003cli\u003e10.4-inch full-color touchscreen — complete standalone operation\u003c\/li\u003e\n      \u003cli\u003ePC software control via direct USB connection\u003c\/li\u003e\n      \u003cli\u003ePower-failure auto-recovery — no data loss, no intervention\u003c\/li\u003e\n      \u003cli\u003e1,000 experimental results stored on-board\u003c\/li\u003e\n      \u003cli\u003eUSB data upload and download\u003c\/li\u003e\n      \u003cli\u003eAbsolute and relative quantification\u003c\/li\u003e\n      \u003cli\u003eSNP genotyping analysis\u003c\/li\u003e\n      \u003cli\u003eMelting curve \/ dissociation curve analysis\u003c\/li\u003e\n      \u003cli\u003eCustomizable report templates — export-ready output\u003c\/li\u003e\n      \u003cli\u003eCompatible: 0.2mL 96-well plates, 8-tube strips, single tubes\u003c\/li\u003e\n      \u003cli\u003eSample dynamic range: 10¹ to 10¹⁰ copies\u003c\/li\u003e\n      \u003cli\u003eCt CV ≤ 0.5% · Linear correlation |r| ≥ 0.999\u003c\/li\u003e\n      \u003cli\u003eIVDR CE certified · EU RoHS compliant · NMPA registered\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 6. FLUORESCENCE CHANNEL GUIDE ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003e4-Channel Fluorescence Configuration\u003c\/p\u003e\n    \u003cp\u003eThe Gentier 96R's four channels cover every probe chemistry used in standard clinical diagnostics, infectious disease multiplex panels, SNP genotyping, and quantitative gene expression analysis — including both hydrolysis probe and intercalating dye formats.\u003c\/p\u003e\n    \u003cdiv class=\"prod-channels\"\u003e\n      \u003cdiv class=\"prod-channel-card\"\u003e\n        \u003cp class=\"prod-channel-label\"\u003eCH 1 · 465nm \/ 510nm\u003c\/p\u003e\n        \u003cp class=\"prod-channel-name\"\u003eFAM \/ SYBR Green I\u003c\/p\u003e\n        \u003cp class=\"prod-channel-dyes\"\u003eFAM · SYBR Green I · SYTO 9 · Eva Green · LC Green\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-channel-card\"\u003e\n        \u003cp class=\"prod-channel-label\"\u003eCH 2 · 527nm \/ 563nm\u003c\/p\u003e\n        \u003cp class=\"prod-channel-name\"\u003eHEX \/ VIC\u003c\/p\u003e\n        \u003cp class=\"prod-channel-dyes\"\u003eHEX · VIC · TET · JOE\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-channel-card\"\u003e\n        \u003cp class=\"prod-channel-label\"\u003eCH 3 · 580nm \/ 616nm\u003c\/p\u003e\n        \u003cp class=\"prod-channel-name\"\u003eROX \/ Texas Red\u003c\/p\u003e\n        \u003cp class=\"prod-channel-dyes\"\u003eROX · Texas Red\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-channel-card\"\u003e\n        \u003cp class=\"prod-channel-label\"\u003eCH 4 · 632nm \/ 664nm\u003c\/p\u003e\n        \u003cp class=\"prod-channel-name\"\u003eCy5\u003c\/p\u003e\n        \u003cp class=\"prod-channel-dyes\"\u003eCy5\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 7. IDEAL APPLICATIONS ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eIdeal Applications\u003c\/p\u003e\n    \u003cdiv class=\"prod-usecases\"\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e🏥\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003eClinical Diagnostics\u003c\/p\u003e\n        \u003cp\u003eInfectious pathogen detection, blood screening, viral load quantification, STI panels, and oncology marker testing in hospital, clinical reference, and public health laboratories where validated 4-dye assay formats are the standard.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e🧬\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003eMolecular Research\u003c\/p\u003e\n        \u003cp\u003eAbsolute and relative gene expression, SNP genotyping, melting curve analysis, and high-throughput quantitative PCR screening in genomics, immunology, forensic science, and pharmacogenomics research workflows.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e🌿\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003eFood, Vet \u0026amp; Environmental\u003c\/p\u003e\n        \u003cp\u003ePathogen detection in food and dairy, animal disease surveillance, environmental health monitoring, and agricultural safety testing at CDC, inspection bureaus, and veterinary diagnostic centers running standardized 4-channel assay panels.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 8. CONNECTIVITY \u0026 INTEGRATION ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eConnectivity \u0026amp; Compatibility\u003c\/p\u003e\n    \u003cp\u003eThe Gentier 96R integrates into existing laboratory infrastructure without workflow disruption — running standalone via touchscreen or connected to PC software, with consumable compatibility spanning all standard 96-well formats.\u003c\/p\u003e\n    \u003cdiv class=\"prod-badges\"\u003e\n      \u003cspan class=\"prod-badge amber\"\u003e10.4\" Touch Screen\u003c\/span\u003e\n      \u003cspan class=\"prod-badge amber\"\u003ePC Software Control\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003eUSB Data Transfer\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003e1,000 Results On-Board\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003eWin 7 \/ 10 \/ 11\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003e96-Well Plates\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003e8-Tube Strips\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003eSingle Tubes (Clear \/ White)\u003c\/span\u003e\n      \u003cspan class=\"prod-badge outline\"\u003eIVDR CE Certified\u003c\/span\u003e\n      \u003cspan class=\"prod-badge outline\"\u003eEU RoHS Compliant\u003c\/span\u003e\n      \u003cspan class=\"prod-badge outline\"\u003eNMPA Registered\u003c\/span\u003e\n      \u003cspan class=\"prod-badge outline\"\u003eAC 100–240V Universal\u003c\/span\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 9. TECHNICAL SPECIFICATIONS ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eTechnical Specifications\u003c\/p\u003e\n    \u003cdiv class=\"prod-specs-wrap\"\u003e\n      \u003ctable class=\"prod-specs-table\"\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr class=\"section-header\"\u003e\u003ctd colspan=\"2\"\u003eSample \u0026amp; Throughput\u003c\/td\u003e\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGentier 96R\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSample Throughput\u003c\/td\u003e\n\u003ctd\u003e1–96 wells per run\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSuitable Consumables\u003c\/td\u003e\n\u003ctd\u003e0.2mL 96-well plates · 8-tube strips · single tubes (clear, frosted, white)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSample Dynamic Range\u003c\/td\u003e\n\u003ctd\u003e10¹ to 10¹⁰ copies\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eLinearity (|r|)\u003c\/td\u003e\n\u003ctd\u003e≥ 0.999\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eRepeatability (Ct CV)\u003c\/td\u003e\n\u003ctd\u003e≤ 0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr class=\"section-header\"\u003e\u003ctd colspan=\"2\"\u003eOptical System\u003c\/td\u003e\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eFluorescence Channels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eFluorescence Scanning Time\u003c\/td\u003e\n\u003ctd\u003e7 seconds (all 96 wells, all channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDetection Method\u003c\/td\u003e\n\u003ctd\u003eSimultaneous well-by-well scanning — no edge effects\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eHigh-brightness, long-life, maintenance-free LED · top excitation\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDetector\u003c\/td\u003e\n\u003ctd\u003ePhotodiodes (PDs) · top scanning\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eFluorescence Dynamic Range\u003c\/td\u003e\n\u003ctd\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eExcitation Wavelengths\u003c\/td\u003e\n\u003ctd\u003eCH1: 465nm · CH2: 527nm · CH3: 580nm · CH4: 632nm\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDetection Wavelengths\u003c\/td\u003e\n\u003ctd\u003eCH1: 510nm · CH2: 563nm · CH3: 616nm · CH4: 664nm\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDye Compatibility\u003c\/td\u003e\n\u003ctd\u003eCH1: FAM, SYBR Green I, SYTO 9, Eva Green, LC Green · CH2: HEX, VIC, TET, JOE · CH3: ROX, Texas Red · CH4: Cy5\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr class=\"section-header\"\u003e\u003ctd colspan=\"2\"\u003eThermal Block\u003c\/td\u003e\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eHeating Method\u003c\/td\u003e\n\u003ctd\u003ePeltier\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eHeating Rate\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 6.1°C\/s (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCooling Rate\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 5.0°C\/s (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eTemperature Uniformity\u003c\/td\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e≤ 0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eGradient Range\u003c\/td\u003e\n\u003ctd\u003e1°C – 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eGradient Block\u003c\/td\u003e\n\u003ctd\u003e12 columns\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSpecial PCR Protocols\u003c\/td\u003e\n\u003ctd\u003eGradient PCR · Touch Down PCR · Long PCR\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr class=\"section-header\"\u003e\u003ctd colspan=\"2\"\u003eSoftware \u0026amp; Control\u003c\/td\u003e\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eControl Mode 1\u003c\/td\u003e\n\u003ctd\u003e10.4-inch full-color touch screen (standalone)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eControl Mode 2\u003c\/td\u003e\n\u003ctd\u003ePC direct control via software\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePC Operating System\u003c\/td\u003e\n\u003ctd\u003eWindows 7 \/ 10 \/ 11\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eData Storage\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 experimental results stored on-board\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eData Transfer\u003c\/td\u003e\n\u003ctd\u003eUSB disk upload\/download\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePower Failure Protection\u003c\/td\u003e\n\u003ctd\u003eAutomatic experiment recovery on power restore — no PC required\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eReporting\u003c\/td\u003e\n\u003ctd\u003eCustomizable experiment report templates\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eAnalysis Functions\u003c\/td\u003e\n\u003ctd\u003eAbsolute quantification · Relative quantification · SNP analysis · Melting curve analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\n          \u003ctr class=\"section-header\"\u003e\u003ctd colspan=\"2\"\u003ePhysical \u0026amp; Electrical\u003c\/td\u003e\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDimensions (W×L×H)\u003c\/td\u003e\n\u003ctd\u003e555 × 475 × 484 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eWeight (Net)\u003c\/td\u003e\n\u003ctd\u003e30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eAC 100–240V, 50–60Hz · 900 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eIVDR CE · NMPA · EU RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 10. WARRANTY \u0026 SUPPORT ── --\u003e\n  \u003cdiv class=\"prod-warranty\"\u003e\n    \u003cspan class=\"prod-warranty-icon\"\u003e🛡️\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cp\u003e\u003cstrong\u003eSurge Scientific Warranty \u0026amp; Support\u003c\/strong\u003e\u003c\/p\u003e\n      \u003cp\u003eThe Gentier 96R is sold through Surge Scientific, your trusted laboratory instrument partner. Our product specialists are available Monday–Friday for pre-sales questions, assay compatibility guidance, and technical support. This instrument is backed by a \u003cstrong\u003e2-year all-inclusive manufacturer's warranty\u003c\/strong\u003e. Contact us at \u003cstrong\u003einfo@surgescientific.com\u003c\/strong\u003e or call \u003cstrong\u003e855.943.3344\u003c\/strong\u003e for quotes, demo requests, and application support.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Tian Long","offers":[{"title":"Default Title","offer_id":48805211111680,"sku":null,"price":15500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/1444\/4544\/files\/96e3.jpg?v=1780681111","url":"https:\/\/surgescientific.com\/products\/gentier-96r-4-channel-real-time-pcr-system","provider":"Surge Scientific","version":"1.0","type":"link"}