{"product_id":"hematocrit-centrifuge","title":"Hematocrit Centrifuge","description":"\u003cstyle\u003e\n.prod-desc{font-size:1em;width:100%;max-width:100%;box-sizing:border-box;font-family:inherit;color:#2c4a4a;line-height:1.6}\n.prod-desc *,.prod-desc *::before,.prod-desc *::after{box-sizing:border-box}\n\n\/* ── HERO ── *\/\n.prod-hero{background:linear-gradient(135deg,#0d2b2b 0%,#0d4a4a 55%,#0a7373 100%);border-radius:0.375em;padding:clamp(1.5em,4vw,2.5em) clamp(1.5em,4vw,3em);margin-bottom:2em;position:relative;overflow:hidden}\n.prod-hero::before{content:'';position:absolute;top:0;left:0;right:0;height:2px;background:linear-gradient(90deg,#bf6000,transparent 70%)}\n.prod-hero::after{content:'';position:absolute;bottom:0;left:0;right:0;height:3px;background:linear-gradient(90deg,#bf6000 0%,#0a7373 60%,transparent 100%)}\n.prod-hero-eyebrow{font-size:0.6875em;font-weight:700;letter-spacing:0.18em;text-transform:uppercase;color:#bf6000;margin-bottom:0.5em}\n.prod-hero h1{font-size:clamp(1.375em,2.5vw,1.875em);font-weight:800;color:#ffffff;line-height:1.15;margin:0 0 0.375em 0}\n.prod-hero-sub{font-size:0.875em;color:rgba(255,255,255,0.5);letter-spacing:0.06em;margin-bottom:1.25em}\n.prod-hero-lead{font-size:1.0625em;font-style:italic;color:rgba(255,255,255,0.85);line-height:1.75;max-width:72ch;margin:0}\n\n\/* ── SECTION TITLES ── *\/\n.prod-section-title{font-size:0.8125em;font-weight:700;letter-spacing:0.2em;text-transform:uppercase;color:#bf6000;margin:0 0 1em 0;display:flex;align-items:center;gap:0.75em}\n.prod-section-title::after{content:'';flex:1;height:1.5px;background:linear-gradient(90deg,#b2dfdb,transparent)}\n\n\/* ── WHY SECTION ── *\/\n.prod-why{margin-bottom:2em}\n.prod-why p{font-size:1em;color:#2c4a4a;line-height:1.75;margin:0 0 0.875em 0}\n.prod-why p:last-child{margin-bottom:0}\n\n\/* ── PILLARS ── *\/\n.prod-pillars{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:1em;margin-bottom:2em}\n.pillar{background:#e0f2f1;border:1px solid #b2dfdb;border-left:4px solid #bf6000;border-radius:0 0.375em 0.375em 0;padding:1.25em}\n.pillar-icon{font-size:1.5em;display:block;margin-bottom:0.4em}\n.pillar-title{font-size:0.8125em;font-weight:700;letter-spacing:0.08em;text-transform:uppercase;color:#0d2b2b;margin:0 0 0.4em 0}\n.pillar p{font-size:0.875em;color:#3a5a5a;line-height:1.65;margin:0}\n\n\/* ── CALLOUT ── *\/\n.prod-callout{background:linear-gradient(135deg,#e0f2f1 0%,#f1fafa 100%);border:1px solid #80cbc4;border-left:5px solid #bf6000;border-radius:0 0.375em 0.375em 0;padding:1.25em 1.5em;margin-bottom:2em}\n.prod-callout p{font-size:1.0625em;color:#2c4a4a;line-height:1.7;margin:0}\n.prod-callout strong{color:#bf6000}\n\n\/* ── FEATURES ── *\/\n.prod-features{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:0.25em 1.5em;margin-bottom:2em;list-style:none;padding:0}\n.prod-features li{font-size:0.875em;color:#2c4a4a;padding:0.4em 0 0.4em 1.5em;position:relative;border-bottom:1px solid #e0f2f1;line-height:1.45}\n.prod-features li::before{content:'✓';position:absolute;left:0;color:#bf6000;font-weight:700;font-size:0.875em}\n\n\/* ── HCT PROCESS BAND ── *\/\n.hct-process{display:grid;grid-template-columns:repeat(4,minmax(0,1fr));gap:0.5em;margin-bottom:2em}\n.hct-step{background:#0d2b2b;border-radius:0.375em;padding:0.875em 0.75em;text-align:center;position:relative}\n.hct-step:not(:last-child)::after{content:'→';position:absolute;right:-0.4em;top:50%;transform:translateY(-50%);color:#bf6000;font-weight:700;font-size:0.875em;z-index:1}\n.hct-step-num{font-size:0.5625em;font-weight:700;letter-spacing:0.16em;text-transform:uppercase;color:#bf6000;margin-bottom:0.3em}\n.hct-step-title{font-size:0.75em;font-weight:700;color:#ffffff;margin-bottom:0.25em;line-height:1.3}\n.hct-step p{font-size:0.6875em;color:rgba(255,255,255,0.5);line-height:1.4;margin:0}\n\n\/* ── ROTOR COMPARISON ── *\/\n.prod-rotors{margin-bottom:2em}\n.rotor-grid{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:0.875em}\n.rotor-card{background:#0d4a4a;border-radius:0.375em;padding:1.125em 1.25em;border-top:3px solid #bf6000;position:relative}\n.rotor-card-badge{position:absolute;top:0.625em;right:0.625em;font-size:0.5em;font-weight:700;letter-spacing:0.1em;text-transform:uppercase;background:#bf6000;color:#ffffff;padding:0.2em 0.6em;border-radius:2em}\n.rotor-card-icon{font-size:1.25em;display:block;margin-bottom:0.4em}\n.rotor-card-title{font-size:0.75em;font-weight:700;letter-spacing:0.1em;text-transform:uppercase;color:#bf6000;margin-bottom:0.375em}\n.rotor-card p{font-size:0.8125em;color:rgba(255,255,255,0.65);line-height:1.55;margin:0}\n\n\/* ── USE CASES ── *\/\n.prod-usecases{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:0.875em;margin-bottom:2em}\n.usecase-card{background:#0d4a4a;border-radius:0.375em;padding:1.25em 1em;text-align:center}\n.usecase-icon{font-size:1.75em;display:block;margin-bottom:0.5em}\n.usecase-title{font-size:0.75em;font-weight:700;letter-spacing:0.14em;text-transform:uppercase;color:#bf6000;margin-bottom:0.4em}\n.usecase-card p{font-size:0.8125em;color:rgba(255,255,255,0.65);line-height:1.55;margin:0}\n\n\/* ── WHAT'S IN BOX ── *\/\n.prod-inbox{display:flex;flex-wrap:wrap;gap:0.5em;margin-bottom:2em}\n.inbox-badge{font-size:0.75em;font-weight:600;padding:0.35em 0.875em;border-radius:2em;letter-spacing:0.04em}\n.inbox-badge.primary{background:#0d4a4a;color:#ffffff}\n.inbox-badge.accent{background:#bf6000;color:#ffffff}\n.inbox-badge.outline{background:transparent;color:#0d4a4a;border:1.5px solid #b2dfdb}\n\n\/* ── SPECS TABLE ── *\/\n.prod-specs{margin-bottom:2em}\n.spec-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\n.spec-table{width:100%;border-collapse:collapse;font-size:0.875em;min-width:380px}\n.spec-table thead tr{background:#0d4a4a}\n.spec-table thead th{color:#ffffff;font-size:0.6875em;font-weight:700;letter-spacing:0.16em;text-transform:uppercase;padding:0.75em 1em;text-align:left;white-space:nowrap}\n.spec-table tbody tr:nth-child(even){background:#e0f2f1}\n.spec-table tbody tr:hover{background:#fff8e1}\n.spec-table td{padding:0.55em 1em;border-bottom:1px solid #b2dfdb;color:#2c4a4a;vertical-align:top;line-height:1.5}\n.spec-table td:first-child{font-weight:700;color:#0d2b2b;width:42%}\n\n\/* ── WARRANTY ── *\/\n.prod-warranty{background:linear-gradient(135deg,#0a7373 0%,#0d4a4a 100%);border-radius:0.375em;padding:1.25em 1.5em;display:flex;align-items:flex-start;gap:1em}\n.warranty-icon{font-size:1.5em;flex-shrink:0;margin-top:0.1em}\n.warranty-text p{font-size:0.875em;color:rgba(255,255,255,0.8);margin:0 0 0.25em 0;line-height:1.6}\n.warranty-text strong{color:#bf6000}\n.warranty-text p:last-child{margin-bottom:0}\n\n\/* ── RESPONSIVE ── *\/\n@media(max-width:600px){\n  .prod-usecases,.hct-process{grid-template-columns:1fr}\n  .hct-step:not(:last-child)::after{display:none}\n  .rotor-grid{grid-template-columns:1fr}\n}\n@media(max-width:480px){\n  .prod-pillars,.prod-features{grid-template-columns:1fr}\n  .prod-hero h1{font-size:1.25em}\n}\n\u003c\/style\u003e\n\n\u003cdiv class=\"prod-desc\"\u003e\n\n  \u003c!-- 1. HERO --\u003e\n  \u003cdiv class=\"prod-hero\"\u003e\n    \u003cp class=\"prod-hero-eyebrow\"\u003eSurge Scientific · CFG400101 · Hematocrit Centrifuge\u003c\/p\u003e\n    \u003ch1\u003eHematocrit Centrifuge — 12,000 RPM · 14,800 × g · 24 Capillary Tube Rotor Included\u003c\/h1\u003e\n    \u003cp class=\"prod-hero-sub\"\u003ePacked Cell Volume · Erythrocyte Fraction · Bilirubin Assessment · Doping Tests · Micro Blood Separation\u003c\/p\u003e\n    \u003cp class=\"prod-hero-lead\"\u003eHematocrit determination demands a centrifuge purpose-built for capillary tube geometry, precise g-force, and repeatable timing — not a general-purpose microcentrifuge pressed into service with adapters. The CFG400101 is purpose-engineered for the job: 12,000 RPM, 14,800 × g, 24 capillary positions, and a 5-inch HD touchscreen that replaces the knob-and-timer panels that have characterized hematocrit centrifuges for decades.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- 2. WHY SECTION --\u003e\n  \u003cdiv class=\"prod-why\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eWhy Hematocrit Requires a Purpose-Built Instrument\u003c\/p\u003e\n    \u003cp\u003eGeneral-purpose centrifuges with capillary adapters are a compromise that labs accept when budget or bench space forces the issue. The adapter geometry is rarely optimized for 75 mm capillary tubes, rotor balance at 12,000 RPM becomes a concern without a dedicated design, and the absence of an integrated microhematocrit tube reader means every result requires a separate manual measurement step that introduces read error and slows throughput. Conventional keypad-and-knob controls also make precise protocol programming tedious in a clinical workflow where speed and reproducibility are clinical requirements, not preferences.\u003c\/p\u003e\n    \u003cp\u003eThe CFG400101 resolves each of these friction points. The dedicated 24-position capillary rotor is balanced and rated to the full 12,000 RPM — there are no adapters, no compromise geometry. The included Microhematocrit Tube Reader is integrated into the workflow from the first run, eliminating the separate measurement step. Ten acceleration rates and eleven deceleration rates give clinical and research users the protocol flexibility to match any established hematocrit method. And the 5-inch HD touchscreen brings the instrument's parameter interface to the same standard as modern analytical instruments, replacing the tactile ambiguity of legacy analog controls.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- 3. PILLARS --\u003e\n  \u003cdiv class=\"prod-pillars\"\u003e\n    \u003cdiv class=\"pillar\"\u003e\n      \u003cspan class=\"pillar-icon\"\u003e🩸\u003c\/span\u003e\n      \u003cp class=\"pillar-title\"\u003e12,000 RPM · 14,800 × g — Purpose-Built Hematocrit Speed\u003c\/p\u003e\n      \u003cp\u003eMaximum speed of 12,000 RPM generates 14,800 × g — the centrifugal force established by clinical hematology protocols for reliable packed cell volume (PCV) determination. Speed accuracy held to \u003cstrong\u003e±30 RPM\u003c\/strong\u003e ensures the g-force applied to every run matches the protocol specification, run after run, without drift.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"pillar\"\u003e\n      \u003cspan class=\"pillar-icon\"\u003e🖥️\u003c\/span\u003e\n      \u003cp class=\"pillar-title\"\u003e5-Inch HD Touchscreen — Modern Interface, Clinical Precision\u003c\/p\u003e\n      \u003cp\u003eA 5-inch HD touch display replaces the knob-and-timer controls that have defined hematocrit centrifuges since the 1970s. Direct parameter entry for speed, time, acceleration, and deceleration — with multiple user-defined program storage — makes protocol recall instant and eliminates the setting errors introduced by analog dials under time pressure.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"pillar\"\u003e\n      \u003cspan class=\"pillar-icon\"\u003e⚡\u003c\/span\u003e\n      \u003cp class=\"pillar-title\"\u003e10 Acceleration + 11 Deceleration Rates — Protocol Flexibility\u003c\/p\u003e\n      \u003cp\u003eTwenty-one programmable ramp profiles give the CFG400101 the flexibility to match any established hematocrit, PCV, or micro-blood separation protocol precisely. \u003cstrong\u003eGentle deceleration profiles\u003c\/strong\u003e prevent layer disturbance in sensitive separations — a capability absent from fixed-ramp hematocrit centrifuges where braking speed is fixed by motor design.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"pillar\"\u003e\n      \u003cspan class=\"pillar-icon\"\u003e📏\u003c\/span\u003e\n      \u003cp class=\"pillar-title\"\u003eIntegrated Microhematocrit Tube Reader — Eliminates a Workflow Step\u003c\/p\u003e\n      \u003cp\u003eThe included Microhematocrit Tube Reader means hematocrit values are read directly from the rotor without moving tubes to a separate measurement device. One instrument handles centrifugation and measurement — reducing handling, reducing read error, and \u003cstrong\u003ecutting the per-sample workflow to two steps\u003c\/strong\u003e: spin and read.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- 4. CALLOUT --\u003e\n  \u003cdiv class=\"prod-callout\"\u003e\n    \u003cp\u003e\u003cstrong\u003eFrom blood draw to hematocrit result in minutes — no adapters, no separate reader, no manual conversion.\u003c\/strong\u003e The CFG400101's 24-position dedicated capillary rotor, integrated tube reader, and programmable timer deliver the complete hematocrit workflow in a single compact instrument rated to international IVD safety standards.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- 5. KEY FEATURES --\u003e\n  \u003cp class=\"prod-section-title\"\u003eKey Features\u003c\/p\u003e\n  \u003cul class=\"prod-features\"\u003e\n    \u003cli\u003eMaximum speed: 12,000 RPM\u003c\/li\u003e\n    \u003cli\u003eMaximum RCF: 14,800 × g\u003c\/li\u003e\n    \u003cli\u003eSpeed accuracy: ±30 RPM\u003c\/li\u003e\n    \u003cli\u003eStandard rotor: 24-position capillary tube hematocrit rotor\u003c\/li\u003e\n    \u003cli\u003eOptional rotor: 12-position capillary tube rotor\u003c\/li\u003e\n    \u003cli\u003eMicrohematocrit Tube Reader included — integrated measurement\u003c\/li\u003e\n    \u003cli\u003e5-inch HD touchscreen with intuitive parameter interface\u003c\/li\u003e\n    \u003cli\u003e10 user-selectable acceleration rates\u003c\/li\u003e\n    \u003cli\u003e11 user-selectable deceleration rates\u003c\/li\u003e\n    \u003cli\u003eMultiple user-defined program storage for method recall\u003c\/li\u003e\n    \u003cli\u003eTimer range: 1 second to 99 minutes 59 seconds\u003c\/li\u003e\n    \u003cli\u003eMicroprocessor control — high accuracy speed management\u003c\/li\u003e\n    \u003cli\u003eBrushless DC motor — maintenance-free, low-noise operation\u003c\/li\u003e\n    \u003cli\u003eDoor lid interlock — rotor cannot spin with lid open\u003c\/li\u003e\n    \u003cli\u003eConforms to international IVD safety standards\u003c\/li\u003e\n    \u003cli\u003eSuitable for doping test analysis — erythrocyte fraction determination\u003c\/li\u003e\n    \u003cli\u003eNeonatal bilirubin photometric assessment capability\u003c\/li\u003e\n    \u003cli\u003eMicro blood and solution separation applications\u003c\/li\u003e\n    \u003cli\u003eNoise level: ≤65 dB(A)\u003c\/li\u003e\n    \u003cli\u003eUniversal voltage: AC 110 V 60 Hz \/ 220 V 50 Hz\u003c\/li\u003e\n    \u003cli\u003eCompact benchtop footprint: 320 × 370 × 235 mm\u003c\/li\u003e\n    \u003cli\u003eNet weight: 11 kg\u003c\/li\u003e\n    \u003cli\u003eTwo-year all-inclusive manufacturer's warranty\u003c\/li\u003e\n    \u003cli\u003eIn stock — ships from New Jersey warehouse\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003c!-- 6. HCT WORKFLOW BAND --\u003e\n  \u003cp class=\"prod-section-title\"\u003eThe Hematocrit Workflow — Four Steps, One Instrument\u003c\/p\u003e\n  \u003cdiv class=\"hct-process\"\u003e\n    \u003cdiv class=\"hct-step\"\u003e\n      \u003cp class=\"hct-step-num\"\u003eStep 1\u003c\/p\u003e\n      \u003cp class=\"hct-step-title\"\u003eLoad Capillary Tubes\u003c\/p\u003e\n      \u003cp\u003eLoad up to 24 heparinized capillary tubes into the dedicated rotor — no adapters, no rebalancing\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"hct-step\"\u003e\n      \u003cp class=\"hct-step-num\"\u003eStep 2\u003c\/p\u003e\n      \u003cp class=\"hct-step-title\"\u003eSet Protocol\u003c\/p\u003e\n      \u003cp\u003eEnter speed, time and ramp rates via the 5-inch HD touchscreen — or recall a stored program instantly\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"hct-step\"\u003e\n      \u003cp class=\"hct-step-num\"\u003eStep 3\u003c\/p\u003e\n      \u003cp class=\"hct-step-title\"\u003eCentrifuge at 14,800 × g\u003c\/p\u003e\n      \u003cp\u003eRun at up to 12,000 RPM with ±30 RPM accuracy — matching any established PCV protocol specification\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"hct-step\"\u003e\n      \u003cp class=\"hct-step-num\"\u003eStep 4\u003c\/p\u003e\n      \u003cp class=\"hct-step-title\"\u003eRead Directly\u003c\/p\u003e\n      \u003cp\u003eApply the included Microhematocrit Tube Reader to the spun capillary — read PCV value immediately, no separate device\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- 7. ROTOR OPTIONS --\u003e\n  \u003cdiv class=\"prod-rotors\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eRotor Options\u003c\/p\u003e\n    \u003cdiv class=\"rotor-grid\"\u003e\n      \u003cdiv class=\"rotor-card\"\u003e\n        \u003cspan class=\"rotor-card-badge\"\u003eIncluded\u003c\/span\u003e\n        \u003cspan class=\"rotor-card-icon\"\u003e🩸\u003c\/span\u003e\n        \u003cp class=\"rotor-card-title\"\u003e24-Position Capillary Tube Rotor\u003c\/p\u003e\n        \u003cp\u003eStandard configuration. Accommodates 24 standard heparinized capillary tubes (1 mm × 75 mm format). Rated to 12,000 RPM \/ 14,800 × g. Balanced rotor designed specifically for this instrument — no adapter compromise. Microhematocrit Tube Reader included.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"rotor-card\"\u003e\n        \u003cspan class=\"rotor-card-icon\"\u003e🔬\u003c\/span\u003e\n        \u003cp class=\"rotor-card-title\"\u003e12-Position Capillary Tube Rotor\u003c\/p\u003e\n        \u003cp\u003eOptional half-capacity rotor for lower-throughput workflows or when processing odd-numbered sample batches where 24-position loading would leave unbalanced positions. Same speed rating as the standard rotor.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- 8. USE CASES --\u003e\n  \u003cp class=\"prod-section-title\"\u003eIdeal Applications\u003c\/p\u003e\n  \u003cdiv class=\"prod-usecases\"\u003e\n    \u003cdiv class=\"usecase-card\"\u003e\n      \u003cspan class=\"usecase-icon\"\u003e🏥\u003c\/span\u003e\n      \u003cp class=\"usecase-title\"\u003eClinical Hematology Laboratory\u003c\/p\u003e\n      \u003cp\u003eRoutine packed cell volume and erythrocyte fraction determination from EDTA or heparinized whole blood. The integrated reader and programmable timer support high-throughput clinical workflows with consistent, reproducible results.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"usecase-card\"\u003e\n      \u003cspan class=\"usecase-icon\"\u003e🍼\u003c\/span\u003e\n      \u003cp class=\"usecase-title\"\u003eNeonatal \u0026amp; Pediatric Diagnostics\u003c\/p\u003e\n      \u003cp\u003ePhotometric bilirubin assessment from neonatal blood specimens and micro-volume pediatric samples. The 24-capillary capacity accommodates the small sample volumes characteristic of neonatal draw protocols without batch size compromise.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"usecase-card\"\u003e\n      \u003cspan class=\"usecase-icon\"\u003e🐾\u003c\/span\u003e\n      \u003cp class=\"usecase-title\"\u003eVeterinary Practice \u0026amp; Sports Medicine\u003c\/p\u003e\n      \u003cp\u003eHematocrit determination for animal hematology in veterinary clinics, and erythrocyte volume fraction analysis for doping control testing in sports medicine — both applications where the instrument's accuracy and IVD compliance are non-negotiable.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- 9. WHAT'S IN THE BOX --\u003e\n  \u003cp class=\"prod-section-title\"\u003eWhat's in the Box\u003c\/p\u003e\n  \u003cdiv class=\"prod-inbox\"\u003e\n    \u003cspan class=\"inbox-badge primary\"\u003eCFG400101 Hematocrit Centrifuge Unit\u003c\/span\u003e\n    \u003cspan class=\"inbox-badge accent\"\u003e24-Position Capillary Tube Rotor\u003c\/span\u003e\n    \u003cspan class=\"inbox-badge accent\"\u003eMicrohematocrit Tube Reader\u003c\/span\u003e\n    \u003cspan class=\"inbox-badge primary\"\u003eRotor Lid\u003c\/span\u003e\n    \u003cspan class=\"inbox-badge outline\"\u003ePower Cord\u003c\/span\u003e\n    \u003cspan class=\"inbox-badge outline\"\u003eUser Manual\u003c\/span\u003e\n    \u003cspan class=\"inbox-badge outline\"\u003e2-Year Warranty Card\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- 10. SPECS TABLE --\u003e\n  \u003cdiv class=\"prod-specs\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eTechnical Specifications\u003c\/p\u003e\n    \u003cdiv class=\"spec-table-wrap\"\u003e\n      \u003ctable class=\"spec-table\"\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCFG400101\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eMaximum Speed\u003c\/td\u003e\n\u003ctd\u003e12,000 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eMaximum RCF\u003c\/td\u003e\n\u003ctd\u003e14,800 × g\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSpeed Accuracy\u003c\/td\u003e\n\u003ctd\u003e±30 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eStandard Rotor\u003c\/td\u003e\n\u003ctd\u003e24-position capillary tube hematocrit rotor\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eOptional Rotor\u003c\/td\u003e\n\u003ctd\u003e12-position capillary tube rotor\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eMicrohematocrit Tube Reader\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eTimer Range\u003c\/td\u003e\n\u003ctd\u003e1 second to 99 minutes 59 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eAcceleration Rates\u003c\/td\u003e\n\u003ctd\u003e10 user-selectable rates\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDeceleration Rates\u003c\/td\u003e\n\u003ctd\u003e11 user-selectable rates\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePrograms\u003c\/td\u003e\n\u003ctd\u003eMultiple user-defined program storage\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e5-inch HD touchscreen with intuitive interface\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eMotor Type\u003c\/td\u003e\n\u003ctd\u003eBrushless DC — maintenance-free, low-noise\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSafety Devices\u003c\/td\u003e\n\u003ctd\u003eDoor lid interlock · Overspeed protection\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eNoise Level\u003c\/td\u003e\n\u003ctd\u003e≤65 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003eAC 110 V 60 Hz \/ 220 V 50 Hz, 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e320 × 370 × 235 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd\u003eInternational IVD safety standards · CE\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-year all-inclusive manufacturer's warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- 11. WARRANTY STRIP --\u003e\n  \u003cdiv class=\"prod-warranty\"\u003e\n    \u003cspan class=\"warranty-icon\"\u003e🛡️\u003c\/span\u003e\n    \u003cdiv class=\"warranty-text\"\u003e\n      \u003cp\u003e\u003cstrong\u003eSurge Scientific Warranty \u0026amp; Support\u003c\/strong\u003e\u003c\/p\u003e\n      \u003cp\u003eEvery CFG400101 ships with a \u003cstrong\u003e2-year all-inclusive manufacturer's warranty\u003c\/strong\u003e covering parts and labor. Our instrument specialists are available for rotor selection, protocol setup, and post-purchase support. Contact us at \u003cstrong\u003e855.943.3344\u003c\/strong\u003e or \u003cstrong\u003einfo@SurgeScientific.com\u003c\/strong\u003e. In stock at our New Jersey warehouse — most orders ship within 1–2 business days.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Four E's","offers":[{"title":"Default Title","offer_id":48229739856128,"sku":"CFG400101","price":1645.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/1444\/4544\/files\/Foure_s_HC001_1_1809x_c9d58029-3408-4766-81e0-10d3a9c9c388.png?v=1775152005","url":"https:\/\/surgescientific.com\/products\/hematocrit-centrifuge","provider":"Surge Scientific","version":"1.0","type":"link"}