{"product_id":"micro-volume-spectrophotometer-spt-nanof-uv-vis-full-spectrum-with-built-in-fluorescence-detection","title":"Micro Volume Spectrophotometer SPT NanoF with built in Fluorescence Detection","description":"\u003c!-- Surge Scientific — SPT-NanoF Micro Volume Spectrophotometer --\u003e\n\n\u003cstyle\u003e\n  :root {\n    --teal-deepest:#0d2b2b; --teal-dark:#0d4a4a; --teal-mid:#0a7373;\n    --amber:#bf6000; --teal-light:#e0f2f1; --teal-border:#b2dfdb;\n    --teal-pale:#80cbc4; --text-body:#2c4a4a; --text-secondary:#3a5a5a;\n    --hover-amber:#fff8e1; --white:#ffffff;\n  }\n  .prod-desc {\n    font-family:'Georgia','Times New Roman',serif; font-size:1em;\n    color:var(--teal-deepest); width:100%; max-width:100%;\n    box-sizing:border-box; line-height:1.7;\n  }\n  .prod-hero {\n    background:linear-gradient(135deg,#0d2b2b 0%,#0d4a4a 50%,#0a7373 100%);\n    color:var(--white); padding:clamp(1.5em,4vw,3em) clamp(1.25em,3vw,2.5em);\n    border-radius:4px; margin-bottom:clamp(1.5em,3vw,2.5em);\n    position:relative; overflow:hidden; box-sizing:border-box;\n  }\n  .prod-hero::before {\n    content:''; position:absolute; top:-60px; right:-60px;\n    width:220px; height:220px; border-radius:50%;\n    background:rgba(191,96,0,0.12);\n  }\n  .prod-hero::after {\n    content:''; position:absolute; bottom:-40px; left:35%;\n    width:160px; height:160px; border-radius:50%;\n    background:rgba(224,242,241,0.07);\n  }\n  .prod-hero-eyebrow {\n    font-family:'Arial',sans-serif; font-size:0.6875em; font-weight:700;\n    letter-spacing:0.18em; text-transform:uppercase;\n    color:var(--amber); margin:0 0 0.75em;\n  }\n  .prod-hero h1 {\n    font-family:'Arial',sans-serif; font-size:clamp(1.375em,2.5vw,1.875em);\n    font-weight:800; margin:0 0 0.5em; color:var(--white); line-height:1.2;\n  }\n  .prod-hero-sub {\n    font-family:'Arial',sans-serif; font-size:0.875em;\n    color:rgba(255,255,255,0.65); margin:0 0 1.5em; letter-spacing:0.04em;\n  }\n  .prod-hero-lead {\n    font-size:1.0625em; color:rgba(255,255,255,0.88);\n    max-width:100%; margin:0; line-height:1.75; font-style:italic;\n  }\n  .prod-section { margin-bottom:clamp(1.5em,3vw,2.5em); }\n  .prod-section-title {\n    font-family:'Arial',sans-serif; font-size:0.8125em; font-weight:700;\n    letter-spacing:0.18em; text-transform:uppercase;\n    color:var(--amber); border-bottom:2px solid var(--amber);\n    padding-bottom:0.5em; margin:0 0 1.25em; display:inline-block;\n  }\n  .prod-section p { font-size:1em; color:var(--text-body); margin:0 0 0.875em; }\n  .prod-pillars {\n    display:grid; grid-template-columns:repeat(2,minmax(0,1fr));\n    gap:clamp(0.75em,2vw,1em); margin-bottom:clamp(1.5em,3vw,2.5em);\n  }\n  .prod-pillar {\n    border:1px solid var(--teal-border); border-left:4px solid var(--amber);\n    padding:clamp(0.875em,2vw,1.25em) clamp(0.75em,1.5vw,1.125em);\n    background:var(--teal-light); border-radius:0 4px 4px 0;\n    box-sizing:border-box;\n  }\n  .prod-pillar-icon { font-size:1.5em; margin-bottom:0.5em; display:block; }\n  .prod-pillar-title {\n    font-family:'Arial',sans-serif; font-size:0.8125em; font-weight:700;\n    text-transform:uppercase; letter-spacing:0.06em;\n    color:var(--teal-deepest); margin:0 0 0.375em;\n  }\n  .prod-pillar p { font-size:0.875em; color:var(--text-secondary); margin:0; line-height:1.6; }\n  .prod-callout {\n    background:linear-gradient(135deg,var(--teal-light),#f9fefe);\n    border:1px solid var(--teal-border); border-left:5px solid var(--amber);\n    padding:clamp(0.875em,2vw,1.25em) clamp(0.875em,2vw,1.375em);\n    border-radius:0 4px 4px 0; margin-bottom:clamp(1.5em,3vw,2.5em);\n    box-sizing:border-box;\n  }\n  .prod-callout p { font-size:1.0625em; color:var(--teal-deepest); margin:0; font-style:italic; line-height:1.7; }\n  .prod-callout strong { color:var(--amber); font-style:normal; }\n  .prod-features {\n    list-style:none; padding:0; margin:0 0 1em;\n    display:grid; grid-template-columns:repeat(2,minmax(0,1fr));\n    gap:0.5em 1.5em;\n  }\n  .prod-features li {\n    font-size:0.875em; color:var(--text-body);\n    padding-left:1.375em; position:relative; line-height:1.5;\n  }\n  .prod-features li::before {\n    content:'✓'; position:absolute; left:0;\n    color:var(--amber); font-weight:700; font-size:1em;\n  }\n  .prod-usecases {\n    display:grid; grid-template-columns:repeat(3,minmax(0,1fr));\n    gap:clamp(0.625em,1.5vw,0.875em); margin-bottom:0.5em;\n  }\n  .prod-usecase {\n    background:var(--teal-dark); color:var(--white);\n    padding:clamp(0.875em,2vw,1.125em) clamp(0.75em,1.5vw,1em);\n    border-radius:4px; text-align:center; box-sizing:border-box;\n  }\n  .prod-usecase-icon { font-size:1.625em; display:block; margin-bottom:0.5em; }\n  .prod-usecase-title {\n    font-family:'Arial',sans-serif; font-size:0.75em; font-weight:700;\n    letter-spacing:0.06em; text-transform:uppercase;\n    color:var(--amber); margin-bottom:0.375em;\n  }\n  .prod-usecase p { font-size:0.8125em; color:rgba(255,255,255,0.75); margin:0; line-height:1.5; }\n  .prod-badges { display:flex; flex-wrap:wrap; gap:0.625em; margin-bottom:0.5em; }\n  .prod-badge {\n    font-family:'Arial',sans-serif; font-size:0.6875em; font-weight:700;\n    letter-spacing:0.06em; text-transform:uppercase;\n    background:var(--teal-dark); color:var(--white);\n    padding:0.4em 0.75em; border-radius:2px;\n  }\n  .prod-badge.amber { background:var(--amber); color:var(--white); }\n  .prod-badge.outline {\n    background:transparent; color:var(--teal-dark);\n    border:1.5px solid var(--teal-dark);\n  }\n  .prod-specs-wrap {\n    width:100%; overflow-x:auto;\n    -webkit-overflow-scrolling:touch; margin-bottom:0.5em;\n  }\n  .prod-specs-table {\n    width:100%; min-width:480px; border-collapse:collapse;\n    font-size:0.875em; font-family:'Arial',sans-serif;\n  }\n  .prod-specs-table thead tr { background:var(--teal-dark); color:var(--white); }\n  .prod-specs-table thead th {\n    padding:clamp(0.5em,1.2vw,0.625em) clamp(0.625em,1.5vw,0.875em);\n    text-align:left; font-size:0.6875em;\n    letter-spacing:0.12em; text-transform:uppercase; white-space:nowrap;\n  }\n  .prod-specs-table tbody tr:nth-child(even) { background:var(--teal-light); }\n  .prod-specs-table tbody tr:hover { background:var(--hover-amber); }\n  .prod-specs-table td {\n    padding:clamp(0.5em,1vw,0.5625em) clamp(0.625em,1.5vw,0.875em);\n    border-bottom:1px solid var(--teal-border);\n    color:var(--text-body); vertical-align:top;\n  }\n  .prod-specs-table td:first-child {\n    font-weight:600; color:var(--teal-deepest); width:36%;\n  }\n  .prod-specs-table .section-row td {\n    background:var(--teal-mid); color:var(--white);\n    font-weight:700; text-transform:uppercase;\n    letter-spacing:0.08em; font-size:0.7em;\n    padding:0.5em 0.875em;\n  }\n  .prod-warranty {\n    background:linear-gradient(135deg,#0a7373,#0d4a4a); color:var(--white);\n    padding:clamp(0.875em,2vw,1em) clamp(1em,2.5vw,1.5em);\n    border-radius:4px; display:flex; align-items:flex-start;\n    gap:0.875em; margin-top:clamp(1.5em,3vw,2.5em);\n    box-sizing:border-box;\n  }\n  .prod-warranty-icon { font-size:1.75em; flex-shrink:0; margin-top:0.125em; }\n  .prod-warranty p { margin:0; font-size:0.875em; line-height:1.5; }\n  .prod-warranty strong { color:var(--amber); }\n  @media (max-width:600px) { .prod-usecases { grid-template-columns:1fr; } }\n  @media (max-width:480px) {\n    .prod-pillars, .prod-features { grid-template-columns:1fr; }\n    .prod-hero h1 { font-size:1.25em; }\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"prod-desc\"\u003e\n\n  \u003cdiv class=\"prod-hero\"\u003e\n    \u003cp class=\"prod-hero-eyebrow\"\u003eSurge Scientific · Model SPT-NanoF · Micro Volume Spectrophotometer · 3-in-1: UV-VIS + OD600 + Fluorescence\u003c\/p\u003e\n    \u003ch1\u003eSPT-NanoF Micro Volume Spectrophotometer\u003cbr\u003eUV-VIS 190–800 nm + OD600 + Built-in Fluorescence Detection · 0.5 pg\/µL dsDNA Detection Limit · Xenon Flash Lamp · 7-inch Touchscreen\u003c\/h1\u003e\n    \u003cp class=\"prod-hero-sub\"\u003eUV-VIS + OD600 + Fluorescence · 0.5 pg\/µL dsDNA · The advanced 3-in-1 model · 190–800 nm Full Spectrum · 0.5 µL Minimum Sample Volume · Auto-Ranging Pathlength · 15,000 ng\/µL Maximum dsDNA Detection · 2 ng\/µL Minimum Detection · Xenon Flash Lamp (Zero Warm-Up · 10-Year Service Life) · 2048 px CMOS Detector · 1 nm Wavelength Accuracy · ≤3 nm Spectral Resolution · OD600 Cuvette Mode · 7-inch Color Touchscreen · Android Software · Built-in Printer · USB 2.0 Export · 4.1 kg Compact Footprint\u003c\/p\u003e\n    \u003cp class=\"prod-hero-lead\"\u003e\n      The \u003cstrong\u003eSPT-NanoF\u003c\/strong\u003e is the \u003cstrong\u003eadvanced flagship model\u003c\/strong\u003e in the Surge Scientific micro-volume spectrophotometer family — combining \u003cstrong\u003efull UV-VIS spectral analysis (190–800 nm)\u003c\/strong\u003e, \u003cstrong\u003eOD600 bacterial density measurement\u003c\/strong\u003e, AND a \u003cstrong\u003ebuilt-in fluorescence detection module\u003c\/strong\u003e with \u003cstrong\u003e0.5 pg\/µL dsDNA detection limit\u003c\/strong\u003e in one compact instrument. \u003cstrong\u003eThree measurement modes in one footprint\u003c\/strong\u003e: pedestal UV-VIS for routine DNA \/ protein quantification, cuvette OD600 for bacterial culture density, and fluorescence quantification for the femtogram-class samples (NGS libraries, ctDNA, cfDNA, low-yield extractions) where UV-VIS contamination would inflate the reading. \u003cstrong\u003eExcitation 435–485 nm \/ Emission 530–560 nm\u003c\/strong\u003e filters cover standard fluorescence kits for dsDNA, RNA, and protein quantification. \u003cstrong\u003eR²≥0.995 linear dynamic range\u003c\/strong\u003e with \u003cstrong\u003e≤1.5% repeatability\u003c\/strong\u003e. \u003cstrong\u003eXenon flash lamp\u003c\/strong\u003e with zero warm-up and 10-year service life. \u003cstrong\u003e7-inch color touchscreen\u003c\/strong\u003e running Android software, built-in printer, USB 2.0 export.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eWhy the SPT-NanoF Fluorescence Module Earns the Price Premium\u003c\/p\u003e\n    \u003cp\u003eModern molecular biology labs typically need \u003cstrong\u003eboth UV-VIS and fluorescence quantification\u003c\/strong\u003e — and most buy them as separate instruments at separate price points consuming separate bench space. \u003cstrong\u003eUV-VIS\u003c\/strong\u003e is fast, cheap per sample, and works well for high-concentration samples where minor contamination doesn't materially affect readings. \u003cstrong\u003eFluorescence\u003c\/strong\u003e is roughly \u003cstrong\u003e1000× more sensitive\u003c\/strong\u003e and \u003cstrong\u003eanalyte-specific\u003c\/strong\u003e, but requires reagent kits and slightly slower per-sample reads. Most molecular biology workflows need \u003cstrong\u003eUV-VIS for routine bulk samples\u003c\/strong\u003e and \u003cstrong\u003efluorescence for low-concentration high-stakes QC\u003c\/strong\u003e like NGS library preparation, where a 5% over-quantification due to UV-VIS contamination can mean a failed sequencing run.\u003c\/p\u003e\n    \u003cp\u003eThe \u003cstrong\u003eSPT-NanoF eliminates the need for two instruments\u003c\/strong\u003e. \u003cstrong\u003eSwitch modes on the touchscreen\u003c\/strong\u003e — UV-VIS for the routine extract on the pedestal (260 nm with purity ratios 260\/280 and 260\/230), \u003cstrong\u003efluorescence for the precious NGS library\u003c\/strong\u003e that needs \u003cstrong\u003e0.5 pg\/µL detection\u003c\/strong\u003e in the cuvette slot (with the included PCR Tube Holder for 0.5 mL PCR tubes), \u003cstrong\u003eOD600 for the bacterial culture\u003c\/strong\u003e growing in the incubator. One pedestal, one Xenon lamp, one touchscreen, one USB export, one bench footprint. \u003cstrong\u003eThe 0.5 pg\/µL dsDNA fluorescence sensitivity is competitive with dedicated fluorometers\u003c\/strong\u003e like the Qubit family — which means you don't compromise on quantification quality to get the bench-space and workflow-consolidation advantages. \u003cstrong\u003eFor labs running NGS, ctDNA, cfDNA, or any low-abundance nucleic acid work, the SPT-NanoF is the right purchase from day one.\u003c\/strong\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"prod-pillars\"\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e🔬\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003e3-in-1: UV-VIS + OD600 + Fluorescence\u003c\/p\u003e\n      \u003cp\u003e\u003cstrong\u003eThree detection modes in one instrument\u003c\/strong\u003e — UV-VIS spectrophotometry, OD600 bacterial density, AND fluorescence quantification. Replaces 2–3 separate instruments with one bench footprint.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e🎯\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003e0.5 pg\/µL dsDNA Fluorescence\u003c\/p\u003e\n      \u003cp\u003e\u003cstrong\u003eFemtogram-class sensitivity\u003c\/strong\u003e — competitive with dedicated fluorometers. Detection limit \u003cstrong\u003e0.5 pg\/µL dsDNA\u003c\/strong\u003e. Excitation 435–485 nm \/ Emission 530–560 nm. R²≥0.995 linear range.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e🌈\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003eFull UV-VIS 190–800 nm\u003c\/p\u003e\n      \u003cp\u003eSame 190–800 nm spectral range as the standard SPT-Nano. \u003cstrong\u003e0.5 µL minimum\u003c\/strong\u003e, auto-ranging pathlength, \u003cstrong\u003e15,000 ng\/µL maximum dsDNA\u003c\/strong\u003e without dilution. Full feature parity for routine UV-VIS work.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e📱\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003e7-inch Touchscreen · Android\u003c\/p\u003e\n      \u003cp\u003e\u003cstrong\u003eMode-switch on touchscreen\u003c\/strong\u003e — UV-VIS \/ OD600 \/ fluorescence with one tap. Built-in printer, USB 2.0 export. AC 100-240V universal power supply.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"prod-callout\"\u003e\n    \u003cp\u003e\u003cstrong\u003e\"UV-VIS for the bulk extract. 0.5 pg\/µL fluorescence for the NGS library. OD600 for the bacterial culture. One pedestal, one screen, one bill.\"\u003c\/strong\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eKey Features\u003c\/p\u003e\n    \u003cul class=\"prod-features\"\u003e\n      \u003cli\u003eMicro-volume UV-VIS spectrophotometer\u003c\/li\u003e\n      \u003cli\u003eFull spectral range 190–800 nm\u003c\/li\u003e\n      \u003cli\u003e0.5 µL minimum sample volume\u003c\/li\u003e\n      \u003cli\u003eAuto-ranging pathlength (0.05 \/ 0.2 \/ 1 mm)\u003c\/li\u003e\n      \u003cli\u003e15,000 ng\/µL maximum dsDNA detection\u003c\/li\u003e\n      \u003cli\u003e2 ng\/µL minimum dsDNA detection\u003c\/li\u003e\n      \u003cli\u003e0.06 mg\/mL minimum BSA detection\u003c\/li\u003e\n      \u003cli\u003e440 mg\/mL maximum BSA detection\u003c\/li\u003e\n      \u003cli\u003eNo dilution required for high concentrations\u003c\/li\u003e\n      \u003cli\u003ePedestal sample retention\u003c\/li\u003e\n      \u003cli\u003eAluminum alloy + quartz fiber pedestal\u003c\/li\u003e\n      \u003cli\u003eNo cuvettes required for routine UV-VIS\u003c\/li\u003e\n      \u003cli\u003eXenon flash lamp light source\u003c\/li\u003e\n      \u003cli\u003eZero warm-up time\u003c\/li\u003e\n      \u003cli\u003e10-year lamp service life\u003c\/li\u003e\n      \u003cli\u003e2048 px CMOS detector\u003c\/li\u003e\n      \u003cli\u003e1 nm wavelength accuracy\u003c\/li\u003e\n      \u003cli\u003e≤3 nm spectral resolution\u003c\/li\u003e\n      \u003cli\u003e0.003 Abs precision\u003c\/li\u003e\n      \u003cli\u003e0.04–300 A absorbance range\u003c\/li\u003e\n      \u003cli\u003eBuilt-in OD600 measurement mode\u003c\/li\u003e\n      \u003cli\u003eOD600 cuvette compartment (12.5×12.5×45 mm)\u003c\/li\u003e\n      \u003cli\u003eOD600 LED light source at 600±8 nm\u003c\/li\u003e\n      \u003cli\u003eBuilt-in fluorescence detection module\u003c\/li\u003e\n      \u003cli\u003e0.5 pg\/µL dsDNA fluorescence detection limit\u003c\/li\u003e\n      \u003cli\u003eExcitation 435–485 nm\u003c\/li\u003e\n      \u003cli\u003eEmission 530–560 nm\u003c\/li\u003e\n      \u003cli\u003eR²≥0.995 linear dynamic range\u003c\/li\u003e\n      \u003cli\u003e≤1.5% fluorescence repeatability\u003c\/li\u003e\n      \u003cli\u003e0.5 mL PCR tube fluorescence sample holder\u003c\/li\u003e\n      \u003cli\u003ePCR Tube Holder for Cuvette Slot included\u003c\/li\u003e\n      \u003cli\u003eCompatible with fluorescence quantification kits\u003c\/li\u003e\n      \u003cli\u003e7-inch color LCD touchscreen\u003c\/li\u003e\n      \u003cli\u003eAndroid-based software\u003c\/li\u003e\n      \u003cli\u003eStandalone operation — no PC required\u003c\/li\u003e\n      \u003cli\u003eIntuitive user interface\u003c\/li\u003e\n      \u003cli\u003eBuilt-in printer\u003c\/li\u003e\n      \u003cli\u003eUSB 2.0 data export\u003c\/li\u003e\n      \u003cli\u003eUniversal AC 100–240V power supply\u003c\/li\u003e\n      \u003cli\u003e50\/60 Hz operation\u003c\/li\u003e\n      \u003cli\u003e48W operating power · 8W standby\u003c\/li\u003e\n      \u003cli\u003eCompact footprint (318 × 220 × 205 mm)\u003c\/li\u003e\n      \u003cli\u003eLightweight at 4.1 kg\u003c\/li\u003e\n      \u003cli\u003eSuitable for molecular biology \/ clinical \/ microbiology \/ chemistry \/ pharma R\u0026amp;D\u003c\/li\u003e\n      \u003cli\u003e2-year all-inclusive warranty\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eIdeal Applications\u003c\/p\u003e\n    \u003cdiv class=\"prod-usecases\"\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e🧬\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003eNGS Library Quantification\u003c\/p\u003e\n        \u003cp\u003eNext-generation sequencing library QC where the 0.5 pg\/µL dsDNA fluorescence detection delivers Qubit-class accuracy on the same instrument as routine UV-VIS — eliminates the bench-space and workflow overhead of running a separate fluorometer.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e🔬\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003ectDNA \u0026amp; cfDNA Analysis\u003c\/p\u003e\n        \u003cp\u003eCirculating tumor DNA and cell-free DNA quantification where UV-VIS contamination from co-purified protein \/ RNA would inflate readings — fluorescence mode delivers analyte-specific quantification at femtogram-class sensitivity.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e💊\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003eMulti-Modal Research Cores\u003c\/p\u003e\n        \u003cp\u003eMulti-application research cores running diverse molecular biology workflows — UV-VIS for routine extracts, fluorescence for high-stakes low-abundance samples, OD600 for cultures — all on one calibrated instrument with cross-instrument-free measurement consistency.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eModel Selection Guide\u003c\/p\u003e\n    \u003cp\u003eThe Surge Scientific micro-volume spectrophotometer family offers two configurations. Best for: \u003cstrong\u003elabs running NGS \/ ctDNA \/ cfDNA \/ low-abundance nucleic acid quantification\u003c\/strong\u003e. Pick this variant when your workflow includes femtogram-class samples and the 0.5 pg\/µL fluorescence detection delivers Qubit-class accuracy. The standard SPT-Nano is the right choice for labs without fluorescence requirements.\u003c\/p\u003e\n    \u003cdiv class=\"prod-badges\"\u003e\n      \u003cspan class=\"prod-badge outline\"\u003eSPT-Nano — UV-VIS + OD600 (Standard)\u003c\/span\u003e\n      \u003cspan class=\"prod-badge amber\"\u003eSPT-NanoF — UV-VIS + OD600 + Fluorescence (Advanced)\u003c\/span\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eWhat's in the Box\u003c\/p\u003e\n    \u003cp\u003eThe SPT-NanoF ships ready for routine use — Xenon lamp, touchscreen, printer, USB all integrated.\u003c\/p\u003e\n    \u003cdiv class=\"prod-badges\"\u003e\n      \u003cspan class=\"prod-badge amber\"\u003eSPT-NanoF Spectrophotometer\u003c\/span\u003e\n      \u003cspan class=\"prod-badge amber\"\u003eXenon Flash Lamp (Pre-Installed)\u003c\/span\u003e\n      \u003cspan class=\"prod-badge amber\"\u003e7-inch Color Touchscreen\u003c\/span\u003e\n      \u003cspan class=\"prod-badge amber\"\u003eBuilt-in Printer\u003c\/span\u003e\n      \u003cspan class=\"prod-badge amber\"\u003ePower Adapter (AC 100–240V)\u003c\/span\u003e\n      \u003cspan class=\"prod-badge amber\"\u003eUSB 2.0 Export Cable\u003c\/span\u003e\n      \u003cspan class=\"prod-badge amber\"\u003ePCR Tube Holder for Cuvette Slot\u003c\/span\u003e\n      \u003cspan class=\"prod-badge outline\"\u003eFluorescence Quantification Kit Sold Separately\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003eUser Manual (SPT-Nano_FSPT-Nano Operating Instruction.pdf)\u003c\/span\u003e\n      \u003cspan class=\"prod-badge outline\"\u003eOD600 Cuvettes Sold Separately\u003c\/span\u003e\n      \u003cspan class=\"prod-badge outline\"\u003ePedestal Cleaning Supplies Recommended\u003c\/span\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eTechnical Specifications\u003c\/p\u003e\n    \u003cdiv class=\"prod-specs-wrap\"\u003e\n      \u003ctable class=\"prod-specs-table\"\u003e\n        \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003eModel \/ SKU\u003c\/td\u003e\n\u003ctd\u003eSPT-NanoF\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eMicro-volume UV-VIS spectrophotometer with fluorescence detection module\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr class=\"section-row\"\u003e\u003ctd colspan=\"2\"\u003eOptical \u0026amp; Detection — Shared Across Both Models\u003c\/td\u003e\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eWavelength Range\u003c\/td\u003e\n\u003ctd\u003e190 – 800 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eMinimum Sample Volume\u003c\/td\u003e\n\u003ctd\u003e0.5 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePath Length (Auto-Ranging)\u003c\/td\u003e\n\u003ctd\u003e0.05 mm (high concentration) · 0.2 mm (high concentration) · 1 mm (normal concentration)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eXenon flash lamp — zero warm-up · 10-year service life\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDetector Type\u003c\/td\u003e\n\u003ctd\u003e2048 px CMOS\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSpectral Resolution\u003c\/td\u003e\n\u003ctd\u003e≤ 3 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eAbsorbance Precision\u003c\/td\u003e\n\u003ctd\u003e0.003 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eAbsorbance Accuracy\u003c\/td\u003e\n\u003ctd\u003e1% (4.096 A at 260 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eAbsorbance Range\u003c\/td\u003e\n\u003ctd\u003e0.04 – 300 A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eLower Limit of Detection\u003c\/td\u003e\n\u003ctd\u003e2 ng\/µL dsDNA · 0.06 mg\/mL BSA\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eMaximum Concentration\u003c\/td\u003e\n\u003ctd\u003e15,000 ng\/µL dsDNA · 440 mg\/mL BSA\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSample Pedestal\u003c\/td\u003e\n\u003ctd\u003eAluminum alloy and quartz fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr class=\"section-row\"\u003e\u003ctd colspan=\"2\"\u003eOD600 Bacterial Density Measurement\u003c\/td\u003e\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSample Holder\u003c\/td\u003e\n\u003ctd\u003eCuvette\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCuvette Dimensions\u003c\/td\u003e\n\u003ctd\u003e12.5 × 12.5 × 45 mm · Z-Height 8.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eOD600 Light Source\u003c\/td\u003e\n\u003ctd\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eOD600 Wavelength\u003c\/td\u003e\n\u003ctd\u003e600 ± 8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eOD600 Absorbance Range\u003c\/td\u003e\n\u003ctd\u003e0 – 4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr class=\"section-row\"\u003e\u003ctd colspan=\"2\"\u003eFluorescence Detection — SPT-NanoF Only\u003c\/td\u003e\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSample Holder\u003c\/td\u003e\n\u003ctd\u003e0.5 mL PCR Tube (with PCR Tube Holder for Cuvette Slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eExcitation Filters\u003c\/td\u003e\n\u003ctd\u003e435 – 485 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eEmission Filters\u003c\/td\u003e\n\u003ctd\u003e530 – 560 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eLimit of Detection\u003c\/td\u003e\n\u003ctd\u003e0.5 pg\/µL dsDNA\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eLinear Dynamic Range\u003c\/td\u003e\n\u003ctd\u003eR² ≥ 0.995\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e≤ 1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr class=\"section-row\"\u003e\u003ctd colspan=\"2\"\u003ePower, Software, Connectivity\u003c\/td\u003e\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eAC 100–240V · 50\/60 Hz (universal power adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eOperating Power\u003c\/td\u003e\n\u003ctd\u003e48 W\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eStandby Power\u003c\/td\u003e\n\u003ctd\u003e8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003ctd\u003eAndroid-based\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch color LCD touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eStandalone Operation\u003c\/td\u003e\n\u003ctd\u003eYes — no PC required\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eData Output\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 · Built-in printer\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr class=\"section-row\"\u003e\u003ctd colspan=\"2\"\u003eDimensions \u0026amp; Weight\u003c\/td\u003e\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e318 × 220 × 205 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCompanion Variants\u003c\/td\u003e\n\u003ctd\u003eAlso available as SPT-Nano (without fluorescence)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-year all-inclusive manufacturer warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"prod-warranty\"\u003e\n    \u003cspan class=\"prod-warranty-icon\"\u003e🛡️\u003c\/span\u003e\n    \u003cp\u003e\n      \u003cstrong\u003eSurge Scientific Warranty \u0026amp; Support\u003c\/strong\u003e\u003cbr\u003e\n      This instrument is sold through Surge Scientific, your trusted laboratory equipment partner. Our product specialists are available Monday–Friday for assistance. The SPT-NanoF is backed by a \u003cstrong\u003e2-year all-inclusive manufacturer's warranty\u003c\/strong\u003e. Contact us at \u003cstrong\u003einfo@surgescientific.com\u003c\/strong\u003e or reach out directly to our support team at \u003cstrong\u003e855.943.3344\u003c\/strong\u003e for pre-sales questions, micro-volume measurement protocols, OD600 calibration, fluorescence kit selection, fluorescence calibration, pedestal maintenance, and technical assistance.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Four E's","offers":[{"title":"With Fluorescence","offer_id":48659069763840,"sku":"SPT-Nano","price":9200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/1444\/4544\/files\/SPT-Nano01.433_1920x_3e214826-c3dd-433e-81d5-cf8a85ceda5e.png?v=1775152011","url":"https:\/\/surgescientific.com\/products\/micro-volume-spectrophotometer-spt-nanof-uv-vis-full-spectrum-with-built-in-fluorescence-detection","provider":"Surge Scientific","version":"1.0","type":"link"}