{"product_id":"microlit-aqua-aqs-100","title":"Single Electronic Channel  2 – 100 uL Pipettor AQUA AQS-100","description":"\u003c!-- ============================================================\n     Surge Scientific - Shopify Product Description\n     Product: Surge Scientific AQUA Electronic Single Channel Pipettor - AQS-100\n     Volume Range: 2 – 100 uL\n     Brand: Surge Scientific\n     Athens-theme compatible | em-based | self-contained\n     ============================================================ --\u003e\n\u003cstyle\u003e\n  :root {\n    --teal-deepest:   #0d2b2b;\n    --teal-dark:      #0d4a4a;\n    --teal-mid:       #0a7373;\n    --amber:          #bf6000;\n    --teal-light:     #e0f2f1;\n    --teal-border:    #b2dfdb;\n    --teal-pale:      #80cbc4;\n    --text-body:      #2c4a4a;\n    --text-secondary: #3a5a5a;\n    --hover-amber:    #fff8e1;\n    --white:          #ffffff;\n  }\n  .prod-desc {\n    font-family: 'Georgia', 'Times New Roman', serif;\n    font-size: 1em;\n    color: var(--teal-deepest);\n    width: 100%;\n    max-width: 100%;\n    box-sizing: border-box;\n    line-height: 1.7;\n  }\n  .prod-hero {\n    background: linear-gradient(135deg, #0d2b2b 0%, #0d4a4a 50%, #0a7373 100%);\n    color: var(--white);\n    padding: clamp(1.5em, 4vw, 3em) clamp(1.25em, 3vw, 2.5em);\n    border-radius: 4px;\n    margin-bottom: clamp(1.5em, 3vw, 2.5em);\n    position: relative;\n    overflow: hidden;\n    box-sizing: border-box;\n  }\n  .prod-hero::before {\n    content: ''; position: absolute;\n    top: -60px; right: -60px;\n    width: 220px; height: 220px;\n    border-radius: 50%;\n    background: rgba(191, 96, 0, 0.12);\n  }\n  .prod-hero::after {\n    content: ''; position: absolute;\n    bottom: -40px; left: 35%;\n    width: 160px; height: 160px;\n    border-radius: 50%;\n    background: rgba(224, 242, 241, 0.07);\n  }\n  .prod-hero-eyebrow {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.6875em;\n    font-weight: 700;\n    letter-spacing: 0.18em;\n    text-transform: uppercase;\n    color: var(--amber);\n    margin: 0 0 0.75em;\n  }\n  .prod-hero h1 {\n    font-family: 'Arial', sans-serif;\n    font-size: clamp(1.375em, 2.5vw, 1.875em);\n    font-weight: 800;\n    margin: 0 0 0.5em;\n    color: var(--white);\n    line-height: 1.2;\n  }\n  .prod-hero-sub {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.875em;\n    color: rgba(255,255,255,0.65);\n    margin: 0 0 1.5em;\n    letter-spacing: 0.04em;\n  }\n  .prod-hero-lead {\n    font-size: 1.0625em;\n    color: rgba(255,255,255,0.88);\n    max-width: 100%;\n    margin: 0;\n    line-height: 1.75;\n    font-style: italic;\n  }\n  .prod-section { margin-bottom: clamp(1.5em, 3vw, 2.5em); }\n  .prod-section-title {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.8125em;\n    font-weight: 700;\n    letter-spacing: 0.18em;\n    text-transform: uppercase;\n    color: var(--amber);\n    border-bottom: 2px solid var(--amber);\n    padding-bottom: 0.5em;\n    margin: 0 0 1.25em;\n    display: inline-block;\n  }\n  .prod-section p {\n    font-size: 1em;\n    color: var(--text-body);\n    margin: 0 0 0.875em;\n  }\n  .prod-pillars {\n    display: grid;\n    grid-template-columns: repeat(2, minmax(0, 1fr));\n    gap: clamp(0.75em, 2vw, 1em);\n    margin-bottom: clamp(1.5em, 3vw, 2.5em);\n  }\n  .prod-pillar {\n    border: 1px solid var(--teal-border);\n    border-left: 4px solid var(--amber);\n    padding: clamp(0.875em, 2vw, 1.25em) clamp(0.75em, 1.5vw, 1.125em);\n    background: var(--teal-light);\n    border-radius: 0 4px 4px 0;\n    box-sizing: border-box;\n  }\n  .prod-pillar-icon { font-size: 1.5em; margin-bottom: 0.5em; display: block; }\n  .prod-pillar-title {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.8125em;\n    font-weight: 700;\n    text-transform: uppercase;\n    letter-spacing: 0.06em;\n    color: var(--teal-deepest);\n    margin: 0 0 0.375em;\n  }\n  .prod-pillar p {\n    font-size: 0.875em;\n    color: var(--text-secondary);\n    margin: 0;\n    line-height: 1.6;\n  }\n  .prod-callout {\n    background: linear-gradient(135deg, var(--teal-light), #f9fefe);\n    border: 1px solid var(--teal-border);\n    border-left: 5px solid var(--amber);\n    padding: clamp(0.875em, 2vw, 1.25em) clamp(0.875em, 2vw, 1.375em);\n    border-radius: 0 4px 4px 0;\n    margin-bottom: clamp(1.5em, 3vw, 2.5em);\n    box-sizing: border-box;\n  }\n  .prod-callout p {\n    font-size: 1.0625em;\n    color: var(--teal-deepest);\n    margin: 0;\n    font-style: italic;\n    line-height: 1.7;\n  }\n  .prod-callout strong { color: var(--amber); font-style: normal; }\n  .prod-features {\n    list-style: none;\n    padding: 0; margin: 0 0 1em;\n    display: grid;\n    grid-template-columns: repeat(2, minmax(0, 1fr));\n    gap: 0.5em 1.5em;\n  }\n  .prod-features li {\n    font-size: 0.875em;\n    color: var(--text-body);\n    padding-left: 1.375em;\n    position: relative;\n    line-height: 1.5;\n  }\n  .prod-features li::before {\n    content: '✓';\n    position: absolute;\n    left: 0;\n    color: var(--amber);\n    font-weight: 700;\n    font-size: 1em;\n  }\n  .prod-usecases {\n    display: grid;\n    grid-template-columns: repeat(3, minmax(0, 1fr));\n    gap: clamp(0.625em, 1.5vw, 0.875em);\n    margin-bottom: 0.5em;\n  }\n  .prod-usecase {\n    background: var(--teal-dark);\n    color: var(--white);\n    padding: clamp(0.875em, 2vw, 1.125em) clamp(0.75em, 1.5vw, 1em);\n    border-radius: 4px;\n    text-align: center;\n    box-sizing: border-box;\n  }\n  .prod-usecase-icon { font-size: 1.625em; display: block; margin-bottom: 0.5em; }\n  .prod-usecase-title {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.75em;\n    font-weight: 700;\n    letter-spacing: 0.06em;\n    text-transform: uppercase;\n    color: var(--amber);\n    margin-bottom: 0.375em;\n  }\n  .prod-usecase p {\n    font-size: 0.8125em;\n    color: rgba(255,255,255,0.75);\n    margin: 0;\n    line-height: 1.5;\n  }\n  .prod-badges {\n    display: flex;\n    flex-wrap: wrap;\n    gap: 0.625em;\n    margin-bottom: 0.5em;\n  }\n  .prod-badge {\n    font-family: 'Arial', sans-serif;\n    font-size: 0.6875em;\n    font-weight: 700;\n    letter-spacing: 0.06em;\n    text-transform: uppercase;\n    background: var(--teal-dark);\n    color: var(--white);\n    padding: 0.4em 0.75em;\n    border-radius: 2px;\n  }\n  .prod-badge.amber  { background: var(--amber); color: var(--white); }\n  .prod-badge.outline {\n    background: transparent;\n    color: var(--teal-dark);\n    border: 1.5px solid var(--teal-dark);\n  }\n  .prod-specs-wrap {\n    width: 100%;\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n    margin-bottom: 0.5em;\n  }\n  .prod-specs-table {\n    width: 100%;\n    min-width: 520px;\n    border-collapse: collapse;\n    font-size: 0.875em;\n    font-family: 'Arial', sans-serif;\n  }\n  .prod-specs-table thead tr { background: var(--teal-dark); color: var(--white); }\n  .prod-specs-table thead th {\n    padding: clamp(0.5em, 1.2vw, 0.625em) clamp(0.625em, 1.5vw, 0.875em);\n    text-align: left;\n    font-size: 0.6875em;\n    letter-spacing: 0.12em;\n    text-transform: uppercase;\n    white-space: nowrap;\n  }\n  .prod-specs-table tbody tr:nth-child(even) { background: var(--teal-light); }\n  .prod-specs-table tbody tr:hover { background: var(--hover-amber); }\n  .prod-specs-table td {\n    padding: clamp(0.5em, 1vw, 0.5625em) clamp(0.625em, 1.5vw, 0.875em);\n    border-bottom: 1px solid var(--teal-border);\n    color: var(--text-body);\n    vertical-align: top;\n  }\n  .prod-specs-table td:first-child {\n    font-weight: 600;\n    color: var(--teal-deepest);\n    width: 22%;\n    white-space: nowrap;\n  }\n  .prod-warranty {\n    background: linear-gradient(135deg, #0a7373, #0d4a4a);\n    color: var(--white);\n    padding: clamp(0.875em, 2vw, 1em) clamp(1em, 2.5vw, 1.5em);\n    border-radius: 4px;\n    display: flex;\n    align-items: flex-start;\n    gap: 0.875em;\n    margin-top: clamp(1.5em, 3vw, 2.5em);\n    box-sizing: border-box;\n  }\n  .prod-warranty-icon { font-size: 1.75em; flex-shrink: 0; margin-top: 0.125em; }\n  .prod-warranty p { margin: 0; font-size: 0.875em; line-height: 1.5; }\n  .prod-warranty strong { color: var(--amber); }\n  @media (max-width: 600px) {\n    .prod-usecases { grid-template-columns: 1fr; }\n  }\n  @media (max-width: 480px) {\n    .prod-pillars,\n    .prod-features,\n    .prod-sizes { grid-template-columns: 1fr; }\n    .prod-hero h1 { font-size: 1.25em; }\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"prod-desc\"\u003e\n\n  \u003c!-- 1. HERO --\u003e\n  \u003cdiv class=\"prod-hero\"\u003e\n    \u003cp class=\"prod-hero-eyebrow\"\u003eSurge Scientific · Model AQS-100 · Volume Range 2–100 uL\u003c\/p\u003e\n    \u003ch1\u003eAQUA AQS-100\u003cbr\u003eElectronic Single Channel Pipettor\u003c\/h1\u003e\n    \u003cp class=\"prod-hero-sub\"\u003eELISA \u0026amp; Plate-Loading Workhorse · 0.15% CV at Full Volume · 96-Well Optimized\u003c\/p\u003e\n    \u003cp class=\"prod-hero-lead\"\u003eThe 2–100 uL range is where 96-well plate work lives — sample addition, antibody dilution, ELISA fills. The AQS-100 holds \u003cstrong\u003e0.15% CV at the 100 uL nominal\u003c\/strong\u003e, the kind of intra-plate uniformity that previously required automated liquid handlers.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- 2. WHY --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eWhy The AQS-100?\u003c\/p\u003e\n    \u003cp\u003eELISA results, antibody titrations, and 96-well sample addition workflows all depend on this volume range being delivered identically across the plate. Manual pipettes can hit it once or twice; sustaining that consistency across 96 wells, then 384, then 768, exceeds what the human thumb can deliver.\u003c\/p\u003e\n    \u003cp\u003eThe AQS-100 hits 0.6% accuracy and 0.15% CV at full volume, and pairs that precision with a 12-mode interface that includes \u003cstrong\u003erepetitive dispense and stepper modes\u003c\/strong\u003e — aspirate once, dispense across an entire row in one continuous workflow. Plate-fill time drops while CV holds steady.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- 3. PILLARS --\u003e\n  \u003cdiv class=\"prod-pillars\"\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e🎯\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003e100 uL NOMINAL ACCURACY\u003c\/p\u003e\n      \u003cp\u003eAt full volume, the AQS-100 delivers \u003cstrong\u003e0.60% accuracy and 0.15% CV\u003c\/strong\u003e per the catalog spec, verified against DIN EN ISO 8655-2 at an ISO 17025 accredited lab.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e⚙️\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003eLINEAR STEPPING MOTOR\u003c\/p\u003e\n      \u003cp\u003eMotor-driven piston eliminates the thumb-pressure variability that plagues manual pipettes. Aspiration profiles repeat to \u003cstrong\u003ethe same micro-step every cycle\u003c\/strong\u003e, holding accuracy across thousand-sample runs.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e🔋\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003eDETACHABLE 4.2V LI-ION\u003c\/p\u003e\n      \u003cp\u003e800 mAh rechargeable battery clips off the handle in seconds — \u003cstrong\u003e8 hours of operation\u003c\/strong\u003e per charge, ~2-hour recharge, with USB Type-A and Type-C charger options.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e🎛️\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003e12 MODES + 6 PROGRAMS\u003c\/p\u003e\n      \u003cp\u003eForward, reverse, mix, dilute, gel-load, titration, multi-stage aspirate, repetitive, sequential dispense and more. \u003cstrong\u003eSix programs save to memory\u003c\/strong\u003e for instant recall on repeat assays.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- 4. CALLOUT --\u003e\n  \u003cdiv class=\"prod-callout\"\u003e\n    \u003cp\u003e\n      \u003cstrong\u003e\"0.60% accuracy and 0.15% CV at 100 uL nominal.\"\u003c\/strong\u003e —\n      The AQS-100 is purpose-built for the 2 – 100 uL window — the manufacturer's published spec at the nominal volume sets a precision tier that manual pipettes in this range cannot sustain across a full shift.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- 5. KEY FEATURES --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eKey Features\u003c\/p\u003e\n    \u003cul class=\"prod-features\"\u003e\n      \u003cli\u003eVolume range: 2 – 100 uL\u003c\/li\u003e\n      \u003cli\u003eIncrement resolution: 0.5 uL\u003c\/li\u003e\n      \u003cli\u003e0.60% accuracy at 100 uL nominal\u003c\/li\u003e\n      \u003cli\u003e0.15% CV at 100 uL nominal\u003c\/li\u003e\n      \u003cli\u003eColor-coded volume identification — Light Yellow band\u003c\/li\u003e\n      \u003cli\u003eExternal detachable 4.2V Li-ion rechargeable battery\u003c\/li\u003e\n      \u003cli\u003e800 mAh capacity — 8 hours of operation\u003c\/li\u003e\n      \u003cli\u003e~2-hour full recharge time\u003c\/li\u003e\n      \u003cli\u003eUSB Type-A and Type-C charger compatibility\u003c\/li\u003e\n      \u003cli\u003eLinear stepping electronic piston control\u003c\/li\u003e\n      \u003cli\u003e304 grade stainless steel tip cone\u003c\/li\u003e\n      \u003cli\u003e12 unique modes of operation\u003c\/li\u003e\n      \u003cli\u003eStores 6 user-defined programs in memory\u003c\/li\u003e\n      \u003cli\u003e3-speed pipetting selection (Low \/ Medium \/ High)\u003c\/li\u003e\n      \u003cli\u003e1-inch tempered LCD glass display\u003c\/li\u003e\n      \u003cli\u003eReal-time battery, calibration, and error indicators\u003c\/li\u003e\n      \u003cli\u003eVolume adjustment wheel for one-handed operation\u003c\/li\u003e\n      \u003cli\u003eSoft-key programming interface\u003c\/li\u003e\n      \u003cli\u003eMini USB interface for diagnostics\u003c\/li\u003e\n      \u003cli\u003eManual tip ejection\u003c\/li\u003e\n      \u003cli\u003eUniversal tip cone — accepts standard tip brands\u003c\/li\u003e\n      \u003cli\u003eLower section autoclavable at 121°C, 1 bar, 20 minutes\u003c\/li\u003e\n      \u003cli\u003eWhole-device sterilization by UV light\u003c\/li\u003e\n      \u003cli\u003eISO 17025 calibration certificate included\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- 6. APPLICATIONS --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eIdeal Applications\u003c\/p\u003e\n    \u003cdiv class=\"prod-usecases\"\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e🧪\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003eELISA \u0026amp; IMMUNOASSAY\u003c\/p\u003e\n        \u003cp\u003e96-well plate fills, antibody titrations, and substrate addition where intra-plate CV directly affects result validity.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e🧬\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003eMOLECULAR BIOLOGY\u003c\/p\u003e\n        \u003cp\u003ePCR setup at higher reaction volumes, sample loading for gel electrophoresis, and reagent addition for cloning.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e🔬\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003eCELL-BASED ASSAYS\u003c\/p\u003e\n        \u003cp\u003eCytotoxicity assays, cell viability work, and culture media changes where consistent volume delivery preserves cell health.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- 7. RELATED MODELS IN AQS SERIES --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eOther Models in the AQS Series\u003c\/p\u003e\n    \u003cp\u003eThe AQS-100 is one of seven volume ranges in the Surge Scientific AQUA single-channel platform. All seven share the same handle, firmware, battery, and accessory ecosystem — standardize the bench around a common platform.\u003c\/p\u003e\n    \u003cdiv class=\"prod-badges\"\u003e\n      \u003cspan class=\"prod-badge\"\u003eAQS-10 · 0.2–10 uL\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003eAQS-20 · 0.5–20 uL\u003c\/span\u003e\n      \u003cspan class=\"prod-badge amber\"\u003eAQS-100 · 2–100 uL (this model)\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003eAQS-200 · 5–200 uL\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003eAQS-1000 · 50–1000 uL\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003eAQS-5000 · 0.1–5 mL\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003eAQS-10000 · 1–10 mL\u003c\/span\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- 8. PER-VOLUME ACCURACY TABLE --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eAQS-100 Accuracy \u0026amp; Precision\u003c\/p\u003e\n    \u003cdiv class=\"prod-specs-wrap\"\u003e\n      \u003ctable class=\"prod-specs-table\"\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n            \u003cth\u003eTest Volume\u003c\/th\u003e\n            \u003cth\u003eAccuracy ±%\u003c\/th\u003e\n            \u003cth\u003eAccuracy ±uL\u003c\/th\u003e\n            \u003cth\u003ePrecision CV ±%\u003c\/th\u003e\n            \u003cth\u003ePrecision CV ±uL\u003c\/th\u003e\n          \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003e10 uL\u003c\/td\u003e\n\u003ctd\u003e2.00\u003c\/td\u003e\n\u003ctd\u003e0.20\u003c\/td\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003ctd\u003e0.10\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e50 uL\u003c\/td\u003e\n\u003ctd\u003e0.80\u003c\/td\u003e\n\u003ctd\u003e0.40\u003c\/td\u003e\n\u003ctd\u003e0.30\u003c\/td\u003e\n\u003ctd\u003e0.15\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003e100 uL\u003c\/td\u003e\n\u003ctd\u003e0.60\u003c\/td\u003e\n\u003ctd\u003e0.60\u003c\/td\u003e\n\u003ctd\u003e0.15\u003c\/td\u003e\n\u003ctd\u003e0.15\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n    \u003cp style=\"font-size:0.75em; color: var(--text-secondary); margin-top:0.5em; font-style:italic;\"\u003eError limits in accordance with DIN EN ISO 8655-2, based on the 100 uL nominal capacity. Calibration verified at an ISO 17025 accredited laboratory and supplied with each unit.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECS --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eTechnical Specifications\u003c\/p\u003e\n    \u003cdiv class=\"prod-specs-wrap\"\u003e\n      \u003ctable class=\"prod-specs-table\"\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAQS-100\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eSingle channel electronic pipettor\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eVolume Range\u003c\/td\u003e\n\u003ctd\u003e2 – 100 uL\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eIncrement\u003c\/td\u003e\n\u003ctd\u003e0.5 uL\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eColor Code\u003c\/td\u003e\n\u003ctd\u003eLight Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDrive System\u003c\/td\u003e\n\u003ctd\u003eLinear stepping electronic piston control\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePipetting Modes\u003c\/td\u003e\n\u003ctd\u003e12 (forward, reverse, mix, dilute, gel-load, titration, multi-stage aspirate, sequential, repetitive, manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eMemory Storage\u003c\/td\u003e\n\u003ctd\u003e6 user-defined programs\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSpeed Settings\u003c\/td\u003e\n\u003ctd\u003e3 (Low \/ Medium \/ High)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e1-inch tempered LCD glass\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eVolume Adjustment\u003c\/td\u003e\n\u003ctd\u003eAdjustment wheel + soft keys\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eTip Cone Material\u003c\/td\u003e\n\u003ctd\u003e304 grade stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eTip Compatibility\u003c\/td\u003e\n\u003ctd\u003eUniversal — accepts standard tip brands\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eTip Ejection\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e4.2V Li-ion, 800 mAh, detachable\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e8 hours per full charge\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCharging Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCharger\u003c\/td\u003e\n\u003ctd\u003eUSB Type-A and Type-C\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eUSB Interface\u003c\/td\u003e\n\u003ctd\u003eMini USB\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eAutoclavability\u003c\/td\u003e\n\u003ctd\u003eLower section at 121°C, 1 bar, 20 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eUV Sterilization\u003c\/td\u003e\n\u003ctd\u003eWhole device\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCalibration Standard\u003c\/td\u003e\n\u003ctd\u003eDIN EN ISO 8655-2 (ISO 17025 accredited lab)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, ISO 9001, ISO 13485, ISO 17025\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCarousel Stands\u003c\/td\u003e\n\u003ctd\u003eAvailable separately\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e1-Year Free Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- 9. WARRANTY --\u003e\n  \u003cdiv class=\"prod-warranty\"\u003e\n    \u003cspan class=\"prod-warranty-icon\"\u003e🛡️\u003c\/span\u003e\n    \u003cp\u003e\n      \u003cstrong\u003eSurge Scientific Warranty \u0026amp; Support\u003c\/strong\u003e\u003cbr\u003e\n      This instrument is sold through Surge Scientific, your trusted laboratory equipment partner. Our product specialists are available Monday–Friday for assistance. The AQS-100 is backed by a 1-year all-inclusive manufacturer's warranty. Contact us at \u003ca href=\"mailto:info@surgescientific.com\"\u003e\u003cstrong\u003einfo@surgescientific.com\u003c\/strong\u003e\u003c\/a\u003e or reach out directly to our support team at \u003cstrong\u003e(833) 319-3535\u003c\/strong\u003e for pre-sales questions, ISO 8655 calibration verification, pipetting protocol guidance, accessory orders, and technical assistance.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n","brand":"Microlit","offers":[{"title":"Default Title","offer_id":48668801171712,"sku":"AQS-100","price":484.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/1444\/4544\/files\/AQE-100.jpg?v=1777920147","url":"https:\/\/surgescientific.com\/products\/microlit-aqua-aqs-100","provider":"Surge Scientific","version":"1.0","type":"link"}