{"product_id":"portable-cell-counter-cytocube","title":"Portable Cell Counter – CytoCube™","description":"\u003c!-- Surge Scientific — CytoCube Portable Cell Counter --\u003e\n\n\u003cstyle\u003e\n  :root {\n    --teal-deepest:#0d2b2b; --teal-dark:#0d4a4a; --teal-mid:#0a7373;\n    --amber:#bf6000; --teal-light:#e0f2f1; --teal-border:#b2dfdb;\n    --teal-pale:#80cbc4; --text-body:#2c4a4a; --text-secondary:#3a5a5a;\n    --hover-amber:#fff8e1; --white:#ffffff;\n  }\n  .prod-desc {\n    font-family:'Georgia','Times New Roman',serif; font-size:1em;\n    color:var(--teal-deepest); width:100%; max-width:100%;\n    box-sizing:border-box; line-height:1.7;\n  }\n  .prod-hero {\n    background:linear-gradient(135deg,#0d2b2b 0%,#0d4a4a 50%,#0a7373 100%);\n    color:var(--white); padding:clamp(1.5em,4vw,3em) clamp(1.25em,3vw,2.5em);\n    border-radius:4px; margin-bottom:clamp(1.5em,3vw,2.5em);\n    position:relative; overflow:hidden; box-sizing:border-box;\n  }\n  .prod-hero::before {\n    content:''; position:absolute; top:-60px; right:-60px;\n    width:220px; height:220px; border-radius:50%;\n    background:rgba(191,96,0,0.12);\n  }\n  .prod-hero::after {\n    content:''; position:absolute; bottom:-40px; left:35%;\n    width:160px; height:160px; border-radius:50%;\n    background:rgba(224,242,241,0.07);\n  }\n  .prod-hero-eyebrow {\n    font-family:'Arial',sans-serif; font-size:0.6875em; font-weight:700;\n    letter-spacing:0.18em; text-transform:uppercase;\n    color:var(--amber); margin:0 0 0.75em;\n  }\n  .prod-hero h1 {\n    font-family:'Arial',sans-serif; font-size:clamp(1.375em,2.5vw,1.875em);\n    font-weight:800; margin:0 0 0.5em; color:var(--white); line-height:1.2;\n  }\n  .prod-hero-sub {\n    font-family:'Arial',sans-serif; font-size:0.875em;\n    color:rgba(255,255,255,0.65); margin:0 0 1.5em; letter-spacing:0.04em;\n  }\n  .prod-hero-lead {\n    font-size:1.0625em; color:rgba(255,255,255,0.88);\n    max-width:100%; margin:0; line-height:1.75; font-style:italic;\n  }\n  .prod-section { margin-bottom:clamp(1.5em,3vw,2.5em); }\n  .prod-section-title {\n    font-family:'Arial',sans-serif; font-size:0.8125em; font-weight:700;\n    letter-spacing:0.18em; text-transform:uppercase;\n    color:var(--amber); border-bottom:2px solid var(--amber);\n    padding-bottom:0.5em; margin:0 0 1.25em; display:inline-block;\n  }\n  .prod-section p { font-size:1em; color:var(--text-body); margin:0 0 0.875em; }\n  .prod-pillars {\n    display:grid; grid-template-columns:repeat(2,minmax(0,1fr));\n    gap:clamp(0.75em,2vw,1em); margin-bottom:clamp(1.5em,3vw,2.5em);\n  }\n  .prod-pillar {\n    border:1px solid var(--teal-border); border-left:4px solid var(--amber);\n    padding:clamp(0.875em,2vw,1.25em) clamp(0.75em,1.5vw,1.125em);\n    background:var(--teal-light); border-radius:0 4px 4px 0;\n    box-sizing:border-box;\n  }\n  .prod-pillar-icon { font-size:1.5em; margin-bottom:0.5em; display:block; }\n  .prod-pillar-title {\n    font-family:'Arial',sans-serif; font-size:0.8125em; font-weight:700;\n    text-transform:uppercase; letter-spacing:0.06em;\n    color:var(--teal-deepest); margin:0 0 0.375em;\n  }\n  .prod-pillar p { font-size:0.875em; color:var(--text-secondary); margin:0; line-height:1.6; }\n  .prod-callout {\n    background:linear-gradient(135deg,var(--teal-light),#f9fefe);\n    border:1px solid var(--teal-border); border-left:5px solid var(--amber);\n    padding:clamp(0.875em,2vw,1.25em) clamp(0.875em,2vw,1.375em);\n    border-radius:0 4px 4px 0; margin-bottom:clamp(1.5em,3vw,2.5em);\n    box-sizing:border-box;\n  }\n  .prod-callout p { font-size:1.0625em; color:var(--teal-deepest); margin:0; font-style:italic; line-height:1.7; }\n  .prod-callout strong { color:var(--amber); font-style:normal; }\n  .prod-features {\n    list-style:none; padding:0; margin:0 0 1em;\n    display:grid; grid-template-columns:repeat(2,minmax(0,1fr));\n    gap:0.5em 1.5em;\n  }\n  .prod-features li {\n    font-size:0.875em; color:var(--text-body);\n    padding-left:1.375em; position:relative; line-height:1.5;\n  }\n  .prod-features li::before {\n    content:'✓'; position:absolute; left:0;\n    color:var(--amber); font-weight:700; font-size:1em;\n  }\n  .prod-usecases {\n    display:grid; grid-template-columns:repeat(3,minmax(0,1fr));\n    gap:clamp(0.625em,1.5vw,0.875em); margin-bottom:0.5em;\n  }\n  .prod-usecase {\n    background:var(--teal-dark); color:var(--white);\n    padding:clamp(0.875em,2vw,1.125em) clamp(0.75em,1.5vw,1em);\n    border-radius:4px; text-align:center; box-sizing:border-box;\n  }\n  .prod-usecase-icon { font-size:1.625em; display:block; margin-bottom:0.5em; }\n  .prod-usecase-title {\n    font-family:'Arial',sans-serif; font-size:0.75em; font-weight:700;\n    letter-spacing:0.06em; text-transform:uppercase;\n    color:var(--amber); margin-bottom:0.375em;\n  }\n  .prod-usecase p { font-size:0.8125em; color:rgba(255,255,255,0.75); margin:0; line-height:1.5; }\n  .prod-badges { display:flex; flex-wrap:wrap; gap:0.625em; margin-bottom:0.5em; }\n  .prod-badge {\n    font-family:'Arial',sans-serif; font-size:0.6875em; font-weight:700;\n    letter-spacing:0.06em; text-transform:uppercase;\n    background:var(--teal-dark); color:var(--white);\n    padding:0.4em 0.75em; border-radius:2px;\n  }\n  .prod-badge.amber { background:var(--amber); color:var(--white); }\n  .prod-badge.outline {\n    background:transparent; color:var(--teal-dark);\n    border:1.5px solid var(--teal-dark);\n  }\n  .prod-specs-wrap {\n    width:100%; overflow-x:auto;\n    -webkit-overflow-scrolling:touch; margin-bottom:0.5em;\n  }\n  .prod-specs-table {\n    width:100%; min-width:420px; border-collapse:collapse;\n    font-size:0.875em; font-family:'Arial',sans-serif;\n  }\n  .prod-specs-table thead tr { background:var(--teal-dark); color:var(--white); }\n  .prod-specs-table thead th {\n    padding:clamp(0.5em,1.2vw,0.625em) clamp(0.625em,1.5vw,0.875em);\n    text-align:left; font-size:0.6875em;\n    letter-spacing:0.12em; text-transform:uppercase; white-space:nowrap;\n  }\n  .prod-specs-table tbody tr:nth-child(even) { background:var(--teal-light); }\n  .prod-specs-table tbody tr:hover { background:var(--hover-amber); }\n  .prod-specs-table td {\n    padding:clamp(0.5em,1vw,0.5625em) clamp(0.625em,1.5vw,0.875em);\n    border-bottom:1px solid var(--teal-border);\n    color:var(--text-body); vertical-align:top;\n  }\n  .prod-specs-table td:first-child {\n    font-weight:600; color:var(--teal-deepest); width:36%;\n  }\n  .prod-warranty {\n    background:linear-gradient(135deg,#0a7373,#0d4a4a); color:var(--white);\n    padding:clamp(0.875em,2vw,1em) clamp(1em,2.5vw,1.5em);\n    border-radius:4px; display:flex; align-items:flex-start;\n    gap:0.875em; margin-top:clamp(1.5em,3vw,2.5em);\n    box-sizing:border-box;\n  }\n  .prod-warranty-icon { font-size:1.75em; flex-shrink:0; margin-top:0.125em; }\n  .prod-warranty p { margin:0; font-size:0.875em; line-height:1.5; }\n  .prod-warranty strong { color:var(--amber); }\n  @media (max-width:600px) { .prod-usecases { grid-template-columns:1fr; } }\n  @media (max-width:480px) {\n    .prod-pillars, .prod-features { grid-template-columns:1fr; }\n    .prod-hero h1 { font-size:1.25em; }\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"prod-desc\"\u003e\n\n  \u003cdiv class=\"prod-hero\"\u003e\n    \u003cp class=\"prod-hero-eyebrow\"\u003eSurge Scientific · Model CytoCube · Portable Image-Based Cell Counter\u003c\/p\u003e\n    \u003ch1\u003ePortable Cell Counter — CytoCube\u003cbr\u003e2-Second Read · 6-Sample Slide · Bright Field + Trypan Blue · 1.8 kg\u003c\/h1\u003e\n    \u003cp class=\"prod-hero-sub\"\u003eImage-Based Detection · 6 Sample Slots Per Slide · 2 Sec\/Sample · CV ≤5% · 1×10⁴–3×10⁷ cells\/mL · 25 µL Sample · Up to 10,000 Cells\/Sec Analysis · 0–100% Viability · PDF\/JPG\/XLS Export\u003c\/p\u003e\n    \u003cp class=\"prod-hero-lead\"\u003e\n      The CytoCube is the \u003cstrong\u003e1.8 kg image-based cell counter\u003c\/strong\u003e that does in \u003cstrong\u003e2 seconds per sample\u003c\/strong\u003e what manual hemocytometer counting takes 10 minutes to do — and does it with \u003cstrong\u003eCV ≤5%\u003c\/strong\u003e, \u003cstrong\u003eautomated cell detection and tracking\u003c\/strong\u003e, and \u003cstrong\u003ehigh-resolution multi-focal-plane imaging\u003c\/strong\u003e that captures cell morphology, size, and shape in addition to the count. \u003cstrong\u003eSix sample slots in one slide\u003c\/strong\u003e means batch processing in real time. \u003cstrong\u003e25 µL sample volume\u003c\/strong\u003e protects precious cells. Counts up to \u003cstrong\u003e10,000 cells per second\u003c\/strong\u003e. Bright Field and Trypan Blue modes for total counts and viability assessment in a single device. Compatible with any Windows PC. Export to PDF, JPG, XLS.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eWhy Image-Based Cell Counting Replaces Hemocytometers\u003c\/p\u003e\n    \u003cp\u003e\n      The \u003cstrong\u003ehemocytometer\u003c\/strong\u003e has been the cell counting workhorse for over a century — a glass slide with a precisely etched grid, a microscope, a pipette, and a graduate student counting cells one at a time. It works. It also takes \u003cstrong\u003e5–10 minutes per count\u003c\/strong\u003e, suffers from \u003cstrong\u003eoperator-to-operator variability of 15–25%\u003c\/strong\u003e, fatigues researchers' eyes after a few dozen samples, and produces \u003cstrong\u003eno record\u003c\/strong\u003e beyond a number scribbled in a notebook. For modern cell biology — where one experiment might require dozens of cell counts before lunch, where reproducibility is non-negotiable, and where image-based morphology data has become a publication standard — the hemocytometer is the bottleneck.\n    \u003c\/p\u003e\n    \u003cp\u003e\n      The CytoCube takes a different approach: \u003cstrong\u003eload up to 6 stained samples onto one slide, slide it in, get 6 counts in 12 seconds\u003c\/strong\u003e. The advanced imaging system captures high-resolution images \u003cstrong\u003ein multiple focal planes\u003c\/strong\u003e, automatically detects and tracks cells, and produces \u003cstrong\u003ecell concentration, viability percentage, cell diameter distribution, and morphology data\u003c\/strong\u003e — all exportable to PDF \/ XLS \/ JPG for downstream analysis or publication. \u003cstrong\u003eCV ≤5%\u003c\/strong\u003e means inter-sample variability is at instrument-grade levels, not operator-grade levels. The 1.8 kg footprint and 190×160×82 mm dimensions mean it fits anywhere — including biosafety cabinets where bench space is at a premium.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"prod-pillars\"\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e⚡\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003e2 Seconds Per Sample\u003c\/p\u003e\n      \u003cp\u003e\u003cstrong\u003e2-second read time per sample\u003c\/strong\u003e. \u003cstrong\u003e6 sample slots in one slide\u003c\/strong\u003e = 6 counts in ~12 seconds. Up to \u003cstrong\u003e10,000 cells\/second analysis\u003c\/strong\u003e. Hemocytometer-grade data at automation throughput.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e🎯\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003eCV ≤5% · Image-Based\u003c\/p\u003e\n      \u003cp\u003e\u003cstrong\u003eInter-sample CV ≤5%\u003c\/strong\u003e — instrument-grade reproducibility, not 15–25% operator variability. \u003cstrong\u003eMulti-focal-plane high-resolution imaging\u003c\/strong\u003e captures every cell, even in complex samples.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e🔬\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003eBright Field + Trypan Blue\u003c\/p\u003e\n      \u003cp\u003e\u003cstrong\u003eBright Field mode\u003c\/strong\u003e for total cell count + morphology. \u003cstrong\u003eTrypan Blue mode\u003c\/strong\u003e for viability assessment (0–100%). Both modes in one device — no instrument switching for routine cell-counting workflow.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e📐\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003e1.8 kg · 190 × 160 × 82 mm\u003c\/p\u003e\n      \u003cp\u003e\u003cstrong\u003e1.8 kg, 190 × 160 × 82 mm\u003c\/strong\u003e — fits inside a biosafety cabinet. \u003cstrong\u003e25 µL sample volume\u003c\/strong\u003e. PDF \/ JPG \/ XLS export. Windows PC software included. Wide concentration range (1×10⁴ – 3×10⁷ cells\/mL).\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"prod-callout\"\u003e\n    \u003cp\u003e\n      \u003cstrong\u003e\"Six samples on one slide. Two seconds each. CV under 5%. The image-based cell counter that turns hemocytometer counting from a 10-minute chore into a 12-second answer.\"\u003c\/strong\u003e\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eKey Features\u003c\/p\u003e\n    \u003cul class=\"prod-features\"\u003e\n      \u003cli\u003ePortable image-based cell counter\u003c\/li\u003e\n      \u003cli\u003e6 sample slots in one slide\u003c\/li\u003e\n      \u003cli\u003e2-second read time per sample\u003c\/li\u003e\n      \u003cli\u003eBright Field detection mode\u003c\/li\u003e\n      \u003cli\u003eTrypan Blue viability mode\u003c\/li\u003e\n      \u003cli\u003eCell concentration 1×10⁴ – 3×10⁷ cells\/mL\u003c\/li\u003e\n      \u003cli\u003eCell diameter range 5 – 200 µm\u003c\/li\u003e\n      \u003cli\u003eCell viability range 0 – 100%\u003c\/li\u003e\n      \u003cli\u003eSample volume 25 µL\u003c\/li\u003e\n      \u003cli\u003eCV value ≤5%\u003c\/li\u003e\n      \u003cli\u003eHigh-resolution image capture\u003c\/li\u003e\n      \u003cli\u003eMulti-focal-plane imaging\u003c\/li\u003e\n      \u003cli\u003eAutomated cell detection \u0026amp; tracking\u003c\/li\u003e\n      \u003cli\u003eUp to 10,000 cells\/sec analysis\u003c\/li\u003e\n      \u003cli\u003eCell diameter distribution bar graph\u003c\/li\u003e\n      \u003cli\u003eCell morphology \/ size \/ shape analysis\u003c\/li\u003e\n      \u003cli\u003eLED indicator for active sample slot\u003c\/li\u003e\n      \u003cli\u003eSlide-in\/out sample switching\u003c\/li\u003e\n      \u003cli\u003eCompatible with Windows PC\u003c\/li\u003e\n      \u003cli\u003ePDF \/ JPG \/ XLS data export\u003c\/li\u003e\n      \u003cli\u003e1.8 kg lightweight\u003c\/li\u003e\n      \u003cli\u003e190 × 160 × 82 mm compact footprint\u003c\/li\u003e\n      \u003cli\u003eFits inside biosafety cabinet\u003c\/li\u003e\n      \u003cli\u003eEasy setup and operation\u003c\/li\u003e\n      \u003cli\u003e2-year all-inclusive warranty\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eIdeal Applications\u003c\/p\u003e\n    \u003cdiv class=\"prod-usecases\"\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e🧬\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003eCell Biology Research\u003c\/p\u003e\n        \u003cp\u003eCell biology, immunology, stem cell research — where reproducible cell counts and morphology data underpin every transfection, splitting, and seeding workflow.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e💊\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003eDrug Discovery \u0026amp; Vaccine Dev\u003c\/p\u003e\n        \u003cp\u003eDrug discovery cell viability assays, vaccine development cell culture monitoring, process development optimization — where Trypan Blue viability QC is the cell health gate.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e🏥\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003eClinical \u0026amp; Teaching Labs\u003c\/p\u003e\n        \u003cp\u003eClinical research labs, teaching labs, and core facilities — where mid-volume cell counting throughput meets the need for documented, reproducible results.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eWhat's in the Box\u003c\/p\u003e\n    \u003cp\u003eCytoCube ships ready for immediate cell counting use — Windows PC software downloads from the included link. Trypan Blue and counting slides are commodity consumables.\u003c\/p\u003e\n    \u003cdiv class=\"prod-badges\"\u003e\n      \u003cspan class=\"prod-badge amber\"\u003eCytoCube Cell Counter\u003c\/span\u003e\n      \u003cspan class=\"prod-badge amber\"\u003e6-Slot Sample Slide\u003c\/span\u003e\n      \u003cspan class=\"prod-badge amber\"\u003eWindows PC Software\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003eUSB Cable\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003ePower Adapter\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003eUser Manual\u003c\/span\u003e\n      \u003cspan class=\"prod-badge outline\"\u003eTrypan Blue Reagent (Optional)\u003c\/span\u003e\n      \u003cspan class=\"prod-badge outline\"\u003eCounting Slides (Optional)\u003c\/span\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eTechnical Specifications\u003c\/p\u003e\n    \u003cdiv class=\"prod-specs-wrap\"\u003e\n      \u003ctable class=\"prod-specs-table\"\u003e\n        \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003eModel \/ SKU\u003c\/td\u003e\n\u003ctd\u003eCytoCube\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSample Slots \/ Slide\u003c\/td\u003e\n\u003ctd\u003e6 with Bright Field + Trypan Blue modes\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCV Value\u003c\/td\u003e\n\u003ctd\u003e≤5%\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eMeasuring Time \/ Simple Sample\u003c\/td\u003e\n\u003ctd\u003e2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCell Concentration Range\u003c\/td\u003e\n\u003ctd\u003e1×10⁴ – 3×10⁷ cells\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCell Diameter Range\u003c\/td\u003e\n\u003ctd\u003e5 – 200 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCell Viability Detection Range\u003c\/td\u003e\n\u003ctd\u003e0 – 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e25 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eAnalysis Speed\u003c\/td\u003e\n\u003ctd\u003eUp to 10,000 cells\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eImaging\u003c\/td\u003e\n\u003ctd\u003eHigh-resolution, multi-focal-plane\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDetection Modes\u003c\/td\u003e\n\u003ctd\u003eBright Field · Trypan Blue\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eData Output\u003c\/td\u003e\n\u003ctd\u003ePDF · JPG · XLS\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003ctd\u003eWindows PC software included\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e190 × 160 × 82 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-year all-inclusive\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"prod-warranty\"\u003e\n    \u003cspan class=\"prod-warranty-icon\"\u003e🛡️\u003c\/span\u003e\n    \u003cp\u003e\n      \u003cstrong\u003eSurge Scientific Warranty \u0026amp; Support\u003c\/strong\u003e\u003cbr\u003e\n      This instrument is sold through Surge Scientific, your trusted laboratory equipment partner. Our product specialists are available Monday–Friday for assistance. The CytoCube is backed by a \u003cstrong\u003e2-year all-inclusive manufacturer's warranty\u003c\/strong\u003e. Contact us at \u003cstrong\u003einfo@surgescientific.com\u003c\/strong\u003e or reach out directly to our support team at \u003cstrong\u003e855.943.3344\u003c\/strong\u003e for pre-sales questions, Trypan Blue staining protocols, multi-focal imaging optimization, viability assay setup, and technical assistance.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Four E's","offers":[{"title":"Default Title","offer_id":48229731598592,"sku":"CytoCube","price":4471.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/1444\/4544\/files\/IMG_1177_1680x_b1f41ef9-e6b7-4efc-abcf-7d1518906e34.jpg?v=1775151935","url":"https:\/\/surgescientific.com\/products\/portable-cell-counter-cytocube","provider":"Surge Scientific","version":"1.0","type":"link"}