{"product_id":"recirculating-chiller","title":"Recirculating Chiller","description":"\u003c!-- ============================================================\n     Surge Scientific — Recirculating Chiller\n     Model: CH800 — -20°C, 750W cooling, 30-min cool-down, R290 refrigerant\n     Brand System : Deep Teal (#0d2b2b \/ #0d4a4a \/ #0a7373) + Burnt Amber (#bf6000)\n     Theme        : Athens by Truly Fine Pixels\n     ============================================================ --\u003e\n\n\u003cstyle\u003e\n  :root {\n    --teal-deepest:#0d2b2b; --teal-dark:#0d4a4a; --teal-mid:#0a7373;\n    --amber:#bf6000; --teal-light:#e0f2f1; --teal-border:#b2dfdb;\n    --teal-pale:#80cbc4; --text-body:#2c4a4a; --text-secondary:#3a5a5a;\n    --hover-amber:#fff8e1; --white:#ffffff;\n  }\n  .prod-desc {\n    font-family:'Georgia','Times New Roman',serif; font-size:1em;\n    color:var(--teal-deepest); width:100%; max-width:100%;\n    box-sizing:border-box; line-height:1.7;\n  }\n  .prod-hero {\n    background:linear-gradient(135deg,#0d2b2b 0%,#0d4a4a 50%,#0a7373 100%);\n    color:var(--white); padding:clamp(1.5em,4vw,3em) clamp(1.25em,3vw,2.5em);\n    border-radius:4px; margin-bottom:clamp(1.5em,3vw,2.5em);\n    position:relative; overflow:hidden; box-sizing:border-box;\n  }\n  .prod-hero::before {\n    content:''; position:absolute; top:-60px; right:-60px;\n    width:220px; height:220px; border-radius:50%;\n    background:rgba(191,96,0,0.12);\n  }\n  .prod-hero::after {\n    content:''; position:absolute; bottom:-40px; left:35%;\n    width:160px; height:160px; border-radius:50%;\n    background:rgba(224,242,241,0.07);\n  }\n  .prod-hero-eyebrow {\n    font-family:'Arial',sans-serif; font-size:0.6875em; font-weight:700;\n    letter-spacing:0.18em; text-transform:uppercase;\n    color:var(--amber); margin:0 0 0.75em;\n  }\n  .prod-hero h1 {\n    font-family:'Arial',sans-serif; font-size:clamp(1.375em,2.5vw,1.875em);\n    font-weight:800; margin:0 0 0.5em; color:var(--white); line-height:1.2;\n  }\n  .prod-hero-sub {\n    font-family:'Arial',sans-serif; font-size:0.875em;\n    color:rgba(255,255,255,0.65); margin:0 0 1.5em; letter-spacing:0.04em;\n  }\n  .prod-hero-lead {\n    font-size:1.0625em; color:rgba(255,255,255,0.88);\n    max-width:100%; margin:0; line-height:1.75; font-style:italic;\n  }\n  .prod-section { margin-bottom:clamp(1.5em,3vw,2.5em); }\n  .prod-section-title {\n    font-family:'Arial',sans-serif; font-size:0.8125em; font-weight:700;\n    letter-spacing:0.18em; text-transform:uppercase;\n    color:var(--amber); border-bottom:2px solid var(--amber);\n    padding-bottom:0.5em; margin:0 0 1.25em; display:inline-block;\n  }\n  .prod-section p { font-size:1em; color:var(--text-body); margin:0 0 0.875em; }\n  .prod-pillars {\n    display:grid; grid-template-columns:repeat(2,minmax(0,1fr));\n    gap:clamp(0.75em,2vw,1em); margin-bottom:clamp(1.5em,3vw,2.5em);\n  }\n  .prod-pillar {\n    border:1px solid var(--teal-border); border-left:4px solid var(--amber);\n    padding:clamp(0.875em,2vw,1.25em) clamp(0.75em,1.5vw,1.125em);\n    background:var(--teal-light); border-radius:0 4px 4px 0;\n    box-sizing:border-box;\n  }\n  .prod-pillar-icon { font-size:1.5em; margin-bottom:0.5em; display:block; }\n  .prod-pillar-title {\n    font-family:'Arial',sans-serif; font-size:0.8125em; font-weight:700;\n    text-transform:uppercase; letter-spacing:0.06em;\n    color:var(--teal-deepest); margin:0 0 0.375em;\n  }\n  .prod-pillar p { font-size:0.875em; color:var(--text-secondary); margin:0; line-height:1.6; }\n  .prod-callout {\n    background:linear-gradient(135deg,var(--teal-light),#f9fefe);\n    border:1px solid var(--teal-border); border-left:5px solid var(--amber);\n    padding:clamp(0.875em,2vw,1.25em) clamp(0.875em,2vw,1.375em);\n    border-radius:0 4px 4px 0; margin-bottom:clamp(1.5em,3vw,2.5em);\n    box-sizing:border-box;\n  }\n  .prod-callout p { font-size:1.0625em; color:var(--teal-deepest); margin:0; font-style:italic; line-height:1.7; }\n  .prod-callout strong { color:var(--amber); font-style:normal; }\n  .prod-features {\n    list-style:none; padding:0; margin:0 0 1em;\n    display:grid; grid-template-columns:repeat(2,minmax(0,1fr));\n    gap:0.5em 1.5em;\n  }\n  .prod-features li {\n    font-size:0.875em; color:var(--text-body);\n    padding-left:1.375em; position:relative; line-height:1.5;\n  }\n  .prod-features li::before {\n    content:'✓'; position:absolute; left:0;\n    color:var(--amber); font-weight:700; font-size:1em;\n  }\n  .prod-usecases {\n    display:grid; grid-template-columns:repeat(3,minmax(0,1fr));\n    gap:clamp(0.625em,1.5vw,0.875em); margin-bottom:0.5em;\n  }\n  .prod-usecase {\n    background:var(--teal-dark); color:var(--white);\n    padding:clamp(0.875em,2vw,1.125em) clamp(0.75em,1.5vw,1em);\n    border-radius:4px; text-align:center; box-sizing:border-box;\n  }\n  .prod-usecase-icon { font-size:1.625em; display:block; margin-bottom:0.5em; }\n  .prod-usecase-title {\n    font-family:'Arial',sans-serif; font-size:0.75em; font-weight:700;\n    letter-spacing:0.06em; text-transform:uppercase;\n    color:var(--amber); margin-bottom:0.375em;\n  }\n  .prod-usecase p { font-size:0.8125em; color:rgba(255,255,255,0.75); margin:0; line-height:1.5; }\n  .prod-badges { display:flex; flex-wrap:wrap; gap:0.625em; margin-bottom:0.5em; }\n  .prod-badge {\n    font-family:'Arial',sans-serif; font-size:0.6875em; font-weight:700;\n    letter-spacing:0.06em; text-transform:uppercase;\n    background:var(--teal-dark); color:var(--white);\n    padding:0.4em 0.75em; border-radius:2px;\n  }\n  .prod-badge.amber { background:var(--amber); color:var(--white); }\n  .prod-badge.outline {\n    background:transparent; color:var(--teal-dark);\n    border:1.5px solid var(--teal-dark);\n  }\n  .prod-specs-wrap {\n    width:100%; overflow-x:auto;\n    -webkit-overflow-scrolling:touch; margin-bottom:0.5em;\n  }\n  .prod-specs-table {\n    width:100%; min-width:420px; border-collapse:collapse;\n    font-size:0.875em; font-family:'Arial',sans-serif;\n  }\n  .prod-specs-table thead tr { background:var(--teal-dark); color:var(--white); }\n  .prod-specs-table thead th {\n    padding:clamp(0.5em,1.2vw,0.625em) clamp(0.625em,1.5vw,0.875em);\n    text-align:left; font-size:0.6875em;\n    letter-spacing:0.12em; text-transform:uppercase; white-space:nowrap;\n  }\n  .prod-specs-table tbody tr:nth-child(even) { background:var(--teal-light); }\n  .prod-specs-table tbody tr:hover { background:var(--hover-amber); }\n  .prod-specs-table td {\n    padding:clamp(0.5em,1vw,0.5625em) clamp(0.625em,1.5vw,0.875em);\n    border-bottom:1px solid var(--teal-border);\n    color:var(--text-body); vertical-align:top;\n  }\n  .prod-specs-table td:first-child {\n    font-weight:600; color:var(--teal-deepest); width:36%;\n  }\n  .prod-warranty {\n    background:linear-gradient(135deg,#0a7373,#0d4a4a); color:var(--white);\n    padding:clamp(0.875em,2vw,1em) clamp(1em,2.5vw,1.5em);\n    border-radius:4px; display:flex; align-items:flex-start;\n    gap:0.875em; margin-top:clamp(1.5em,3vw,2.5em);\n    box-sizing:border-box;\n  }\n  .prod-warranty-icon { font-size:1.75em; flex-shrink:0; margin-top:0.125em; }\n  .prod-warranty p { margin:0; font-size:0.875em; line-height:1.5; }\n  .prod-warranty strong { color:var(--amber); }\n  @media (max-width:600px) { .prod-usecases { grid-template-columns:1fr; } }\n  @media (max-width:480px) {\n    .prod-pillars, .prod-features { grid-template-columns:1fr; }\n    .prod-hero h1 { font-size:1.25em; }\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"prod-desc\"\u003e\n\n  \u003c!-- ── 1. HERO BANNER ── --\u003e\n  \u003cdiv class=\"prod-hero\"\u003e\n    \u003cp class=\"prod-hero-eyebrow\"\u003eSurge Scientific · Model CH800 · Recirculating Chiller · -20°C · 750W\u003c\/p\u003e\n    \u003ch1\u003eRecirculating Chiller\u003cbr\u003e-20°C in 30 Minutes · 750 W Cooling · R290 Eco-Refrigerant\u003c\/h1\u003e\n    \u003cp class=\"prod-hero-sub\"\u003e±0.3 K Stability · 22 L\/min Flow · 5 L Bath · 4.3-inch Touchscreen · Stainless Steel · \u0026lt;55 dB · Bench-Fit Footprint\u003c\/p\u003e\n    \u003cp class=\"prod-hero-lead\"\u003e\n      The CH800 delivers \u003cstrong\u003elaboratory-grade closed-loop cooling\u003c\/strong\u003e down to \u003cstrong\u003e-20°C with a 30-minute cool-down from room temperature\u003c\/strong\u003e — and does it in a \u003cstrong\u003e235 × 468 × 535 mm bench-friendly footprint\u003c\/strong\u003e that fits inside a fume hood. \u003cstrong\u003e750 W of compressor cooling power\u003c\/strong\u003e, \u003cstrong\u003e±0.3 K temperature stability\u003c\/strong\u003e per DIN 12876, \u003cstrong\u003e22 L\/min recirculating pump flow\u003c\/strong\u003e, and \u003cstrong\u003eR290 eco-refrigerant\u003c\/strong\u003e compliance — engineered to pair with rotary evaporators, reactor blocks, vapor barriers, and heat exchangers without dragging tap water through your sink line for hours.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 2. WHY A DEDICATED RECIRCULATING CHILLER BEATS TAP WATER ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eWhy a Dedicated Recirculating Chiller Beats Tap Water\u003c\/p\u003e\n    \u003cp\u003e\n      Most labs running a rotary evaporator or jacketed reactor start with the simplest cooling solution: \u003cstrong\u003econnect a hose to the tap, run the cold water through the condenser, and let it drain\u003c\/strong\u003e. It works — until you actually look at what it costs. A typical rotary evaporator condenser runs \u003cstrong\u003e2–4 L\/min of water for 4–8 hours per session\u003c\/strong\u003e. That's 500–2,000 L of treated municipal water per day going straight down the drain. Across a year, the water bill alone often exceeds the price of a chiller.\n    \u003c\/p\u003e\n    \u003cp\u003e\n      And tap water has a problem the bill doesn't even capture: \u003cstrong\u003eit's typically 15–22°C, which is far too warm\u003c\/strong\u003e for efficient solvent recovery on volatile organics like dichloromethane, ether, or pentane. Vapors slip past the condenser, end up in the vacuum pump, and your solvent recovery drops to 60–70%. The CH800 holds your condenser fluid at \u003cstrong\u003eany temperature from -20°C to ambient\u003c\/strong\u003e, with \u003cstrong\u003e±0.3 K stability\u003c\/strong\u003e — so cold-trap chemistry actually traps cold, and your solvent recovery climbs to 95%+. \u003cstrong\u003eClosed-loop. Zero water waste. Genuinely cold.\u003c\/strong\u003e\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 3. FOUR VALUE PILLARS ── --\u003e\n  \u003cdiv class=\"prod-pillars\"\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e❄️\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003e-20°C in 30 Minutes\u003c\/p\u003e\n      \u003cp\u003eFast cool-down: \u003cstrong\u003eRT (25°C) to -20°C in ≤30 minutes\u003c\/strong\u003e. \u003cstrong\u003e750 W cooling capacity at 20°C\u003c\/strong\u003e, 500 W at 0°C, 200 W at -20°C — real cooling power across the full operating range.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e🎯\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003e±0.3 K Stability\u003c\/p\u003e\n      \u003cp\u003e\u003cstrong\u003eDIN 12876-compliant ±0.3 K temperature stability\u003c\/strong\u003e with advanced proportional cooling control. Your cold trap stays cold, your solvent recovery stays consistent, your reaction temperature stays predictable.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e🌱\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003eR290 Eco-Refrigerant\u003c\/p\u003e\n      \u003cp\u003eUses \u003cstrong\u003eR290 environmental-friendly refrigerant\u003c\/strong\u003e — low GWP, no ozone depletion, regulatory-future-proof. No HFC retrofit forced on you in three years when the next phase-out hits.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"prod-pillar\"\u003e\n      \u003cspan class=\"prod-pillar-icon\"\u003e📱\u003c\/span\u003e\n      \u003cp class=\"prod-pillar-title\"\u003e4.3-inch Touchscreen + RS485\u003c\/p\u003e\n      \u003cp\u003e\u003cstrong\u003e4.3-inch LCD touchscreen\u003c\/strong\u003e for setpoint, monitoring, and alarms. \u003cstrong\u003eRS485 communication interface\u003c\/strong\u003e for integration with reactor controllers or LIMS. Auto-recovery after power outage — picks up where it left off.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 4. CALLOUT BOX ── --\u003e\n  \u003cdiv class=\"prod-callout\"\u003e\n    \u003cp\u003e\n      \u003cstrong\u003e\"Closed-loop. -20°C. 30 minutes. Stop letting your solvent recovery rate be limited by your tap water temperature.\"\u003c\/strong\u003e —\n      For any rotary evaporator, jacketed reactor, or cold-trap workflow, the CH800 is the cooling upgrade that pays for itself in solvent recovery alone.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 5. KEY FEATURES ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eKey Features\u003c\/p\u003e\n    \u003cul class=\"prod-features\"\u003e\n      \u003cli\u003eWorking temperature -20°C to ambient (RT)\u003c\/li\u003e\n      \u003cli\u003eFast cool-down: RT → -20°C in ≤30 min\u003c\/li\u003e\n      \u003cli\u003e750 W cooling capacity at 20°C\u003c\/li\u003e\n      \u003cli\u003e650 W cooling capacity at 10°C\u003c\/li\u003e\n      \u003cli\u003e500 W cooling capacity at 0°C\u003c\/li\u003e\n      \u003cli\u003e400 W cooling capacity at -10°C\u003c\/li\u003e\n      \u003cli\u003e200 W cooling capacity at -20°C\u003c\/li\u003e\n      \u003cli\u003ePump flow up to 22 L\/min\u003c\/li\u003e\n      \u003cli\u003ePump pressure up to 1 bar\u003c\/li\u003e\n      \u003cli\u003e5 L bath volume (5.3 L max storage)\u003c\/li\u003e\n      \u003cli\u003eTemperature stability ±0.3 K (DIN 12876)\u003c\/li\u003e\n      \u003cli\u003eTemperature display accuracy ±0.3°C\u003c\/li\u003e\n      \u003cli\u003eAdvanced proportional cooling control\u003c\/li\u003e\n      \u003cli\u003eR290 eco-refrigerant — low GWP\u003c\/li\u003e\n      \u003cli\u003eStainless steel bath construction\u003c\/li\u003e\n      \u003cli\u003eVisible water level indicator\u003c\/li\u003e\n      \u003cli\u003eOverflow port protection\u003c\/li\u003e\n      \u003cli\u003eConvenient liquid filling and draining\u003c\/li\u003e\n      \u003cli\u003e4.3-inch LCD touchscreen interface\u003c\/li\u003e\n      \u003cli\u003eReal-time setpoint and monitoring\u003c\/li\u003e\n      \u003cli\u003eOver-current compressor protection\u003c\/li\u003e\n      \u003cli\u003eOverheating protection with audio alarm\u003c\/li\u003e\n      \u003cli\u003eAutomatic recovery after power outage\u003c\/li\u003e\n      \u003cli\u003eRS485 communication interface\u003c\/li\u003e\n      \u003cli\u003eCompact 235 × 468 × 535 mm footprint\u003c\/li\u003e\n      \u003cli\u003eFume-hood compatible dimensions\u003c\/li\u003e\n      \u003cli\u003eLightweight ≤35 kg\u003c\/li\u003e\n      \u003cli\u003eLow noise \u0026lt;55 dB\u003c\/li\u003e\n      \u003cli\u003eDual voltage 100–120V \/ 200–240V\u003c\/li\u003e\n      \u003cli\u003e2-year all-inclusive warranty\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 6. IDEAL APPLICATIONS ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eIdeal Applications\u003c\/p\u003e\n    \u003cdiv class=\"prod-usecases\"\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e🌀\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003eRotary Evaporator Cooling\u003c\/p\u003e\n        \u003cp\u003ePair with rotary evaporators for \u003cstrong\u003esolvent recovery from volatile organics\u003c\/strong\u003e — DCM, ether, pentane, ethanol — where a 5°C condenser dramatically outperforms 20°C tap water.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e⚗️\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003eReactor \u0026amp; Synthesis Cooling\u003c\/p\u003e\n        \u003cp\u003eJacketed reactor blocks, parallel synthesis platforms, exothermic reaction control, and Schlenk-line vapor barriers — anywhere a stable sub-ambient temperature anchors the process.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"prod-usecase\"\u003e\n        \u003cspan class=\"prod-usecase-icon\"\u003e🔬\u003c\/span\u003e\n        \u003cp class=\"prod-usecase-title\"\u003eHeat Exchanger \u0026amp; Lab Cooling\u003c\/p\u003e\n        \u003cp\u003ePhotochemistry stages, optical instruments, NMR cryostat support, and any heat exchanger application where \u003cstrong\u003eclosed-loop, water-saving cooling\u003c\/strong\u003e replaces wasteful tap-water plumbing.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 7. WHAT'S IN THE BOX ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eWhat's in the Box\u003c\/p\u003e\n    \u003cp\u003eThe CH800 ships ready for connection — bench-mount design, ready to plumb into any standard rotary evaporator, jacketed reactor, or heat exchanger. Power supply: 100–120 VAC or 200–240 VAC, 50\/60 Hz.\u003c\/p\u003e\n    \u003cdiv class=\"prod-badges\"\u003e\n      \u003cspan class=\"prod-badge amber\"\u003eCH800 Recirculating Chiller\u003c\/span\u003e\n      \u003cspan class=\"prod-badge amber\"\u003eStainless Steel Bath\u003c\/span\u003e\n      \u003cspan class=\"prod-badge amber\"\u003e4.3-inch LCD Touchscreen\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003ePower Cord\u003c\/span\u003e\n      \u003cspan class=\"prod-badge\"\u003eUser Manual\u003c\/span\u003e\n      \u003cspan class=\"prod-badge outline\"\u003eTubing \u0026amp; Fittings (Match to Application)\u003c\/span\u003e\n      \u003cspan class=\"prod-badge outline\"\u003eRS485 Communication Cable (Optional)\u003c\/span\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 8. TECHNICAL SPECIFICATIONS ── --\u003e\n  \u003cdiv class=\"prod-section\"\u003e\n    \u003cp class=\"prod-section-title\"\u003eTechnical Specifications\u003c\/p\u003e\n    \u003cdiv class=\"prod-specs-wrap\"\u003e\n      \u003ctable class=\"prod-specs-table\"\u003e\n        \u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n\u003ctd\u003eModel \/ SKU\u003c\/td\u003e\n\u003ctd\u003eCH800\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eWorking Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-20°C to ambient (RT)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCooling Capacity @ 20°C\u003c\/td\u003e\n\u003ctd\u003e750 W\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCooling Capacity @ 10°C\u003c\/td\u003e\n\u003ctd\u003e650 W\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCooling Capacity @ 0°C\u003c\/td\u003e\n\u003ctd\u003e500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCooling Capacity @ -10°C\u003c\/td\u003e\n\u003ctd\u003e400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCooling Capacity @ -20°C\u003c\/td\u003e\n\u003ctd\u003e200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCool-Down Time\u003c\/td\u003e\n\u003ctd\u003eRT (25°C) → -20°C in ≤30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePump Flow (Max)\u003c\/td\u003e\n\u003ctd\u003e22 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePump Pressure (Max)\u003c\/td\u003e\n\u003ctd\u003e1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eBath Volume\u003c\/td\u003e\n\u003ctd\u003e5 L (max storage 5.3 L)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eTemperature Stability\u003c\/td\u003e\n\u003ctd\u003e±0.3 K (DIN 12876)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eTemperature Display Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCooling Control\u003c\/td\u003e\n\u003ctd\u003eAdvanced proportional cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR290 (eco-friendly, low GWP)\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eBath Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4.3-inch LCD touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSafety — Compressor\u003c\/td\u003e\n\u003ctd\u003eOver-current protection\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eSafety — Bath\u003c\/td\u003e\n\u003ctd\u003eOverheating protection with audio alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePower Recovery\u003c\/td\u003e\n\u003ctd\u003eAutomatic — restores previous parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100–120 VAC \/ 200–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eWattage (Max)\u003c\/td\u003e\n\u003ctd\u003e750 W\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e235 × 468 × 535 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e≤35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eNoise Level\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;55 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n          \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-year all-inclusive\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- ── 9. WARRANTY \u0026 SUPPORT ── --\u003e\n  \u003cdiv class=\"prod-warranty\"\u003e\n    \u003cspan class=\"prod-warranty-icon\"\u003e🛡️\u003c\/span\u003e\n    \u003cp\u003e\n      \u003cstrong\u003eSurge Scientific Warranty \u0026amp; Support\u003c\/strong\u003e\u003cbr\u003e\n      This instrument is sold through Surge Scientific, your trusted laboratory equipment partner. Our product specialists are available Monday–Friday for assistance. The CH800 is backed by a \u003cstrong\u003e2-year all-inclusive manufacturer's warranty\u003c\/strong\u003e. Contact us at \u003cstrong\u003einfo@surgescientific.com\u003c\/strong\u003e or reach out directly to our support team at \u003cstrong\u003e855.943.3344\u003c\/strong\u003e for pre-sales questions, rotary evaporator pairing, plumbing \u0026amp; tubing guidance, fume-hood installation, and technical assistance.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Four E's","offers":[{"title":"Default Title","offer_id":48229744214272,"sku":"CH800","price":2205.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/1444\/4544\/files\/01_1680x_829bb71b-2936-46cf-b8fa-913a9877795d.jpg?v=1775152057","url":"https:\/\/surgescientific.com\/products\/recirculating-chiller","provider":"Surge Scientific","version":"1.0","type":"link"}