Surge Scientific · Model LILP-200 · Fixed Volume 200 uL · Miniature Format
LILPET PRO LILP-200
Miniature Fixed Volume Micropipette with Tip Ejector
Built-in Tip Ejector · Two-Step Plunger · Designed for Diagnostic Kits
The world's first miniature pipette with a built-in tip ejector, designed specifically for diagnostic kit manufacturing where blood samples, hazardous chemicals, and infectious materials are routine. The LILP-200 delivers a fixed 200 uL dispense with two-step plunger precision and hands-free tip ejection — protecting both the operator and the sample integrity.
Why The LILP-200?
In Rapid Test Kit manufacturing, every workflow involves potentially infectious or hazardous samples. Conventional miniature pipettes force the operator to remove tips by hand — a real safety risk and a contamination vector that disqualifies the pipette from regulated diagnostic environments.
The LILP-200 solves both problems with the world's first built-in tip ejector in a miniature format. Patent filed by Microlit in 2023, the LILPET PRO line is recognized with the India Design Mark Good Design Award 2019 and the Japanese Good Design Award 2019. The two-step plunger ensures last-drop dispensing for the prescribed ISO 8655 accuracy on every cycle.
FITS DIAGNOSTIC KITS
At 130 mm in length, the LILP-200 is engineered to fit inside Rapid Test Kit packaging, making it the standard for veterinary kits, beta-lactam testing, tetracycline testing, HbA1c testing, milk testing, and drug abuse testing.
0.8% AT 200 uL
At nominal volume, the LILP-200 delivers 0.8% accuracy and 0.3% CV per the catalog spec, verified against DIN EN ISO 8655-2 at Microlit's NABL-accredited ISO 17025 lab.
BUILT-IN TIP EJECTOR
The world's first miniature pipette with a tip ejector. Discard used tips without hand contact — critical for blood samples, infectious materials, and hazardous chemicals.
TWO-STEP PLUNGER
The two-step plunger operation enables last-drop dispensing and reverse pipetting, achieving the accuracy and CV figures prescribed by ISO 8655 standards even on viscous samples.
"World's first miniature pipette with a tip ejector — 0.8% accuracy at 200 uL." — The LILP-200 brings hands-free tip ejection to the diagnostic kit industry — safer for the operator, cleaner for the sample, faster for the production line.
Key Features
- Built-in tip ejector — world's first in a miniature pipette
- Hands-free tip removal for hazardous-sample workflows
- Fixed volume: 200 uL
- Two-step plunger operation (forward + reverse pipetting)
- Last-drop dispensing for highest accuracy
- 130 mm length — designed to fit inside Rapid Test Kits
- Universal tip cone — accepts standard 200 uL tips and 20 uL ultra-micro tips
- Calibrated in NABL-accredited lab according to ISO 17025 standards
- Conforms to DIN EN ISO 8655-2 calibration standards
- Calibration certificate included with every unit
- Fully autoclavable at 121°C, 15 psi for 10-15 minutes
- Lightweight design for comfortable single-hand operation
- Available as customizable OEM product
- 1-Year Free Replacement Warranty
- Patent filed (Microlit, 2023)
- India Design Mark: Good Design Award 2019
- Japanese Good Design Award 2019
Ideal Applications
RAPID TEST KIT MANUFACTURING
Production-scale Rapid Test Kit assembly where every unit must dispense identical 200 uL volumes for kit validity.
FOOD & BEVERAGE TESTING
Pathogen detection, contamination screening, and quality control workflows where blood samples, hazardous chemicals, and infectious materials — the built-in tip ejector lets the operator discard tips without hand contact.
CELL CULTURE PREP
Reagent additions, media preparation, and routine cell culture work at higher fixed volumes.
Other Models in the LILPET PRO Range
The LILP-200 is one of 7 fixed-volume models in the LILPET PRO miniature micropipette platform. All share the same 130 mm form factor, two-step plunger, and ISO 8655 calibration certificate.
Don't need the tip ejector? The standard LILPET range offers the same 7 volumes and ISO 8655 calibration at a lower price point:
LILP-200 Accuracy & Precision
| Volume | Accuracy ±% | Precision CV ±% |
|---|---|---|
| 200 uL | 0.8 | 0.3 |
Error limits in accordance with DIN EN ISO 8655-2, based on the nominal capacity. Calibrated at Microlit's NABL/ISO 17025 accredited laboratory; calibration certificate supplied with every unit.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | LILP-200 |
| Configuration | Single-channel miniature fixed-volume micropipette |
| Volume | 200 uL (fixed) |
| Accuracy | ±0.8% |
| Precision (CV) | ±0.3% |
| Length | 130 mm (designed to fit inside Rapid Test Kits) |
| Plunger Operation | Two-step (forward + reverse pipetting, last-drop dispensing) |
| Tip Cone | Universal — accepts standard 200 uL tips and ultra-micro 20 uL tips |
| Tip Ejection | Built-in tip ejector (patent filed) |
| Color Scheme | Blue & White (5-200 uL range) |
| Autoclavability | Fully autoclavable at 121°C, 15 psi for 10-15 minutes |
| Calibration Standard | DIN EN ISO 8655-2 (NABL / ISO 17025 accredited lab) |
| Certifications | CE, ISO 9001, ISO 13485, ISO 17025 |
| Awards | India Design Mark: Good Design Award 2019; Japanese Good Design Award 2019 |
| OEM Customization | Available as customizable OEM product (color customization) |
| Warranty | 1-Year Free Replacement |
Surge Scientific Warranty & Support
This instrument is sold through Surge Scientific, your trusted laboratory equipment partner. Our product specialists are available Monday–Friday for assistance. The LILP-200 is backed by a 1-year all-inclusive manufacturer's warranty. Contact us at info@surgescientific.com or reach out directly to our support team at (833) 319-3535 for pre-sales questions, ISO 8655 calibration verification, pipetting protocol guidance, accessory orders, and technical assistance.