Surge Scientific · Model NRO-T-200 · 12-Channel · 20-200 uL
NERO NRO-T-200 12-Channel Pipettor
12-Channel Multi-Channel · 20-200 uL · UniCal® Recalibration
Multi-channel plate workflows demand consistency every 12 channels can sustain across the row. The NRO-T-200 brings NERO's UniCal® recalibration and µAir® zero-dead-air system to 12-channel format, holding 0.8% accuracy and 0.3% CV at the 200 uL nominal across the full row.
Why The NRO-T-200?
In ELISA, qPCR plate setup, and clinical screening, channel-to-channel volume variability is the single largest source of intra-plate CV. Manual multi-channel pipettes cannot eliminate it — the operator's thumb controls all 12 plungers, and force distributes unevenly across the row.
The NRO-T-200 extends NERO's single-channel precision platform to multi-channel work. UniCal® recalibration in under 30 seconds keeps the entire 12-channel head in spec without sending the instrument out for service, while the sequential tip ejector simplifies tip removal between transfers. The pipette fills a full 96-well plate row in one stroke.
UniCal® CALIBRATION
NERO's patented UniCal® technology lets you recalibrate in under 30 seconds in a single step — no disengaging digits, no third-party service, no instrument downtime.
0.8% AT 200 uL
At full volume, the NRO-T-200 delivers 0.8% accuracy and 0.3% CV per the catalog spec across all 12 channels, verified at Microlit's ISO 17025 NABL lab.
µAir® ZERO DEAD-AIR
NERO's µAir® technology eliminates the dead-air space between piston and liquid — delivering accuracy and repeatability that conventional micropipettes cannot reach, especially at sub-microliter volumes.
3-5N PLUNGER FORCE
Ultra-soft plunger requires only 3-5N of force for the first stop — the lightest pipetting experience in the industry, designed to eliminate repetitive strain injury (RSI) on long protocols.
"12 channels, UniCal® recalibration, 0.8% accuracy at 200 uL." — The NRO-T-200 brings NERO's patented in-house recalibration to multi-channel plate work — the precision platform extended across an entire plate row in a single stroke.
Key Features
- 12-channel configuration
- Fixed 9 mm tip spacing — matches 96-well plate format
- Volume range: 20 - 200 uL
- Increment: 0.2 uL
- 0.8% accuracy at full nominal volume
- 0.3% CV at full nominal volume
- Color-coded volume identification — Dark Yellow band
- Sequential tip ejector for one-by-one tip release
- Easy-to-read 4-digit display
- Soft-grip handle for fatigue-free operation
- Light weight for long-duration pipetting
- Operates flexibly & with ease
- UniCal® technology - recalibrate in 30 seconds
- µAir® zero dead-air space technology
- 3-5N ultra-soft plunger force (RSI-protective)
- Spring & ball-based self-locking digital display
- Universal tip cone - accepts standard tip brands
- Polypropylene chemical-resistant housing
- Fully autoclavable at 121°C, 15 psi for 15-20 mins
- Minimalistic design with seamless surface for cleaning
- Effortless pipetting with ultra-soft plunger
- ISO 17025 (NABL) calibration certificate included
- Conforms to DIN EN ISO 8655-2 standards
- India Design Mark: Good Design Award 2021
- 1-Year Free Replacement Warranty
Ideal Applications
ELISA & IMMUNOASSAY
96-well plate fills, antibody titrations, and substrate addition where intra-plate CV affects assay validity.
MOLECULAR BIOLOGY
Higher-volume PCR setup, sample loading, and plate row distribution.
CELL-BASED ASSAYS
Cytotoxicity assays, cell viability work, and culture media changes across plate rows.
Other Models in the NERO 12-Channel Range
The NRO-T-200 is one of 6 volume tiers in the NERO 12-channel platform. All share the same handle, UniCal® technology, sequential tip ejector, and accessory ecosystem.
Need 8-channel instead? The same six volume ranges are also available in 8-channel:
NRO-T-200 Accuracy & Precision
| Test Volume | Accuracy ±% | Accuracy ±uL | Precision CV ±% | Precision CV ±uL |
|---|---|---|---|---|
| 200 uL (nominal) | 0.8 | 1.6 | 0.3 | 0.6 |
Error limits in accordance with DIN EN ISO 8655-2, based on the nominal capacity. Calibrated at Microlit's NABL/ISO 17025 accredited laboratory; calibration certificate supplied with every unit.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | NRO-T-200 |
| Configuration | 12-channel multi-channel pipettor |
| Volume Type | Variable |
| Volume Range | 20 - 200 uL |
| Increment | 0.2 uL |
| Channels | 12 |
| Tip Spacing | Fixed 9 mm (matches 96-well plate format) |
| Calibration Technology | UniCal® (Indian Patent No. 405607) |
| Air-Space Technology | µAir® zero dead-air space (Patent No. 4787901) |
| Plunger Force | 3-5N for first step (ultra-soft) |
| Digital Display | Spring & ball-based self-locking digital system |
| Tip Cone | Universal — accepts standard tip brands |
| Tip Ejection | Sequential tip ejector |
| Housing Material | Polypropylene (chemical resistant) |
| Autoclavability | Fully autoclavable at 121°C, 15 psi for 15-20 minutes |
| Calibration Standard | DIN EN ISO 8655-2 (NABL / ISO 17025 accredited lab) |
| Certifications | CE, ISO 9001, ISO 13485, ISO 17025 |
| Awards | India Design Mark: Good Design Award 2021 |
| Warranty | 1-Year Free Replacement |
Surge Scientific Warranty & Support
This instrument is sold through Surge Scientific, your trusted laboratory equipment partner. Our product specialists are available Monday–Friday for assistance. The NRO-T-200 is backed by a 1-year all-inclusive manufacturer's warranty. Contact us at info@surgescientific.com or reach out directly to our support team at (833) 319-3535 for pre-sales questions, ISO 8655 calibration verification, pipetting protocol guidance, accessory orders, and technical assistance.